Broad beam transmission data for the shielding of brachytherapy facilities

2008

medicine.medical_specialtyOpticsOncologybusiness.industrymedicine.medical_treatmentElectromagnetic shieldingBrachytherapymedicineRadiology Nuclear Medicine and imagingMedical physicsBeam transmissionbusinessBrachytherapy
researchProduct

A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate Ir-192 brachytherapy

2017

PurposeA joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) Ir-19…

HDR brachytherapymedicine.medical_specialtyComputer sciencemedicine.medical_treatmentBrachytherapyEQUATION SOLVERIr-192computer.software_genreGEC-ESTROImaging phantom030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineMONTE-CARLOlawVoxelGEOMETRIESShielded cableAAPMmedicineMedical physicsRadiation treatment planningGEANT4business.industryMonte Carlo methodsGeneral MedicineDOSIMETRIC ACCURACYTRANSPORTmodel based dose calculation3. Good healthRadiation therapyTG-186030220 oncology & carcinogenesisAbsorbed doseSIMULATIONshielded applicatorTG-43 FORMALISMNuclear medicinebusinessDose rateAlgorithmcomputer
researchProduct

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

2014

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was…

PhysicsPhotonsPhotonbusiness.industryRadiotherapy Planning Computer-AssistedBrachytherapyMonte Carlo methodMonte Carlo method for photon transportGeneral MedicineSuperposition principleRadiation ProtectionOpticsTransmission curveElectromagnetic shieldingEmission spectrumbusinessMonte Carlo MethodBeam (structure)Medical Physics
researchProduct

Implementation and Validation of an End-to-End Commissioning Process for Model-Based Dose Calculation Algorithms in Brachytherapy

2016

medicine.medical_specialtyDose calculationProject commissioningbusiness.industrymedicine.medical_treatmentBrachytherapyProcess (computing)Reliability engineeringOncologyEnd-to-end principlemedicineRadiology Nuclear Medicine and imagingMedical physicsbusinessBrachytherapy
researchProduct

Source strength determination in iridium-192 and cobalt-60 brachytherapy : A European survey on the level of agreement between clinical measurements …

2021

Background and purpose: Brachytherapy treatment outcomes depend on the accuracy of the delivered dose distribution, which is proportional to the reference air-kerma rate (RAKR). Current societal recommendations require the medical physicist to compare the measured RAKR values to the manufacturer source calibration certificate. The purpose of this work was to report agreement observed in current clinical practice in the European Union. Materials and methods: A European survey was performed for high- and pulsed-dose-rate (HDR and PDR) highenergy sources (Ir-192 and Co-60), to quantify observed RAKR differences. Medical physicists at eighteen hospitals from eight European countries were contac…

medicine.medical_specialtymedicine.medical_treatmentBrachytherapyTreatment outcomeBrachytherapyR895-920HDRDose distributionMedical physicistMedical physics. Medical radiology. Nuclear medicinePDRmedicinemedia_common.cataloged_instanceRadiology Nuclear Medicine and imagingMedical physicsOriginal Research ArticleEuropean unionRC254-282media_commonRadiationCobalt 60 brachytherapybusiness.industryRAKRNeoplasms. Tumors. Oncology. Including cancer and carcinogensCertificateSource strengthCalibrationRadiologi och bildbehandlingbusinessRAKR; Calibration; HDR; PDR; BrachytherapyRadiology Nuclear Medicine and Medical Imaging
researchProduct

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

2008

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…

medicine.medical_specialtyMaterials sciencePhotonbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiationComputational physicsElectromagnetic shieldingmedicineMedical physicsRadiation protectionbusinessHalf-value layerBeam (structure)Medical Physics
researchProduct

SU-E-T-509: DICOM Test Case Plans for Model-Based Dose Calculations Methods in Brachytherapy

2013

Purpose: The TG‐186 report provides guidance to early adopters of model‐based dose calculation algorithms (MBDCAs) for brachytherapy. A charge of the AAPM‐ESTRO Working Group on MBDCA is to develop well‐defined test case plans, available as references for the software commissioning process to be performed by end‐users. The aim of this work is to develop test case plans for a generic HDR 192 Ir source alone and in combination with a vaginal cylinder applicator with 180° tungsten‐alloy shielding in a DICOM‐based water phantom. Methods: A DICOM CT dataset was created with a 30 cm diameter water sphere surrounded by air. The voxel size was 1.33×1.33×1.33 mm3 for evaluating absorbed dose rate (c…

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral Medicinecomputer.software_genreImaging phantomDICOMVoxelConsistency (statistics)medicineComputational statisticsDosimetryNuclear medicinebusinesscomputerMedical Physics
researchProduct

Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC-ESTRO

2017

Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Seed Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston). Given increasingly closer interactions among physicists in North America and Europe, the AAPM and the Groupe Europeen de Curietherapie-European Society for Radiotherapy & Oncology (GEC…

Research Reportmedicine.medical_specialtymedicine.medical_treatmentBrachytherapyBrachytherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation oncologymedicineHumansDosimetryMedical physicsRadiometryRadiation treatment planningRadiation oncologistPhotonsTask groupbusiness.industryRadiotherapy DosageGeneral MedicineEurope030220 oncology & carcinogenesisPatient dosebusinessMonte Carlo MethodQuality assuranceMedical Physics
researchProduct

A generic high-dose rate192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

2015

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-b ...

PhysicsTask groupmedicine.medical_specialtyDose calculationmedicine.medical_treatmentBrachytherapyGeneral MedicineBrachytherapy sourceComputational physicsFormalism (philosophy of mathematics)Medical imagingmedicineDosimetryMedical physicsDose rateMedical Physics
researchProduct

Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.

2014

In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emit…

Models Statisticalbusiness.industryComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapyBrachytherapyPublic Health Environmental and Occupational HealthGeneral MedicineRadiation DosageBunkerKermaRadiation ProtectionSpainmedicineScattering RadiationComputer SimulationHospital Design and ConstructionHealth FacilitiesRadiation protectionbusinessRadiometryWaste Management and DisposalMonte Carlo MethodSimulationJournal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Erratum: “Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC-ESTRO” [Med. Phys. Vol 44 …

2018

03 medical and health sciencesTask groupmedicine.medical_specialty0302 clinical medicinebusiness.industry030220 oncology & carcinogenesismedicineMedical physicsGeneral MedicinebusinessJoint (audio engineering)030218 nuclear medicine & medical imagingMedical Physics
researchProduct

Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM

2014

Background and purpose: A substantial reduction of uncertainties in clinical brachytherapy should result in improved outcome in terms of increased local control and reduced side effects. Types of uncertainties have to be identified, grouped, and quantified. Methods: A detailed literature review was performed to identify uncertainty components and their relative importance to the combined overall uncertainty. Results: Very few components (e.g., source strength and afterloader timer) are independent of clinical disease site and location of administered dose. While the influence of medium on dose calculation can be substantial for low energy sources or non-deeply seated implants, the influence…

OncologyRadiology Nuclear Medicine and imagingNeoplasmsDosimetryPractice Guidelines as TopicBrachytherapyUncertaintyHumansHematologyDose Fractionation RadiationGuidelinesUncertaintiesTreatment planning
researchProduct