0000000000060536

AUTHOR

David Mascali

showing 4 related works from this author

Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection ofNa231+ions

2016

This work describes the utilization of an injected 23Na1+ ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 1011  cm−3 or higher. The experimental results are compared to simulations of the 23Na1+ capture into t…

Nuclear and High Energy PhysicsMaterials sciencePhysics and Astronomy (miscellaneous)Ion beam010308 nuclear & particles physicsSurfaces and Interfaces7. Clean energy01 natural sciencesFourier transform ion cyclotron resonanceElectron cyclotron resonanceIon source010305 fluids & plasmasIonBreeder (animal)Physics::Plasma PhysicsIonization0103 physical sciencesAtomic physicsIon cyclotron resonancePhysical Review Accelerators and Beams
researchProduct

Effect of electron cyclotron resonance ion source frequency tuning on ion beam intensity and quality at Department of Physics, University of Jyväskyl…

2010

Ion beam intensity and quality have a crucial effect on the operation efficiency of the accelerator facilities. This paper presents the investigations on the ion beam intensity and quality after the mass separation performed with the Department of Physics, University of Jyvaskyla 14 GHz electron cyclotron resonance ion source by sweeping the microwave in the 14.05–14.13 GHz range. In many cases a clear variation in the ion beam intensity and quality as a function of the frequency was observed. The effect of frequency tuning increased with the charge state. In addition, clear changes in the beam structure seen with the beam viewer were observed. The results confirmed that frequency tuning ca…

PhysicsIon beamCyclotron resonanceHighly charged ionParticle acceleratorIon sourceElectron cyclotron resonancelaw.inventionlawPhysics::Accelerator PhysicsAtomic physicsInstrumentationIon cyclotron resonanceBeam (structure)The Review of scientific instruments
researchProduct

A novel approach to β-decay: PANDORA, a new experimental setup for future in-plasma measurements

2022

International audience; Theoretical predictions as well as experiments performed at storage rings have shown that the lifetimes of β-radionuclides can change significantly as a function of the ionization state. In this paper we describe an innovative approach, based on the use of a compact plasma trap to emulate selected stellar-like conditions. It has been proposed within the PANDORA project (Plasmas for Astrophysics, Nuclear Decay Observation and Radiation for Archaeometry) with the aim to measure, for the first time in plasma, nuclear β-decay rates of radionuclides involved in nuclear-astrophysics processes. To achieve this task, a compact magnetic plasma trap has been designed…

plasma diagnosticsastrofysiikkaPlasma trapGeneral Physics and AstronomynucleosynthesisBeta decayplasmatekniikkaplasmafysiikkaPlasma diagnosticsilmaisimetbeta decay; nucleosynthesis; plasma trap; plasma diagnosticsbeta decay[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]ydinfysiikkaBeta decay; Nucleosynthesis; Plasma diagnostics; Plasma trapNucleosynthesisplasma trap
researchProduct

A status report of the multipurpose superconducting electron cyclotron resonance ion source

2007

Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up to now since the time of pioneering experiment of R. Geller at CEA, Grenoble, and this trend is not deemed to get the saturation at least in the next decade, according to the increased availability of powerful magnets and microwave generators. Electron density above 1013 cm(-3) and very high current of multiply charged ions are expected with the use of 28 GHz microwave heating and of an adequate …

PhysicsElectron density[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonanceParticle accelerator01 natural sciences7. Clean energyIon sourceElectron cyclotron resonanceCharged particle010305 fluids & plasmaslaw.inventionIon29.25.NiIon sources: positive and negativelaw0103 physical sciencesAtomic physics010306 general physicsInstrumentationMicrowave
researchProduct