0000000000066777

AUTHOR

Lucía Fernández-estevan

Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients

Background This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). Material and Methods This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile…

research product

Clinical Behavior of Short Dental Implants: Systematic Review and Meta-Analysis

Short implants are an increasingly common alternative to other surgical techniques in areas where bone availability is reduced. Despite the advantages they offer, a variety of biological repercussions have been described in the literature that can even lead to the loss of these. The aim of this systematic review and meta-analysis was to analyze the impact of the use of short implants on their survival and on peri-implant bone loss, evaluating the influence that length, diameter, and crown-to-implant ratio (C/I) have on these parameters. This systematic review was based on guidelines proposed by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). An electronic se…

research product

Clinical Behavior of Ceramic, Hybrid and Composite Onlays. A Systematic Review and Meta-Analysis

A systematic review and meta-analysis was performed to analyze the survival of onlay restorations in the posterior region, their clinical behavior according to the material used (ceramic reinforced with lithium disilicate, conventional feldspathic ceramic or reinforced with leucite; hybrid materials and composite), possible complications, and the factors influencing restoration success. The systematic review was based on the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, without publication date or language restrictions. An electronic search was made in the PubMed, Scopus, Embase, and Cochrane databases. After discarding duplicate publications and stu…

research product

Implant-supported overdenture with horizontal insertion for treating the edentulous atrophic maxilla: A case series

Abstract Statement of problem Rehabilitation of edentulous patients with severe maxillary atrophy is a clinical challenge. Although several treatment options are available, the implant-supported overdenture has been widely advocated. However vertical insertion implant-supported overdentures have drawbacks, including wear, aging, and the continuous maintenance of retention systems. Whether an implant-supported overdenture with a horizontal insertion pathway can overcome these problems is unclear. Purpose The purpose of this observational study was to determine the clinical and biological behavior of a new type of implant-supported overdenture with a horizontal insertion pathway over a mean c…

research product

Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Part II: Soft Tissues

Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years of functional loading. Materials and methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (group GS); cemented crown without finishing line (biologically oriented preparation technique) (group GBOPT); and conventional cemented crown with finishing line (group GCC). After three years in function, clinical parameters (presence of keratinized mucosa, probing depths, bleeding on probing, and radio…

research product

Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Part I: Hard Tissues

Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading. Materials and Methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant b…

research product

Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis

Background: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. Materials and methods: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health …

research product

Digital protocol for creating a virtual gingiva adjacent to teeth with subgingival dental preparations.

Abstract Purpose This article describes a digital technique used to record gingival emergence profiles modeled for the prosthetic restoration of teeth prepared using biologically oriented preparation technique (BOPT). Materials and methods The description of the technique of intraoral recording, manipulation of digital files, and chairside protocol of prosthetic restorations is developed in the present manuscript on two anterior teeth treated with vertical and subgingival dental preparations for restoration with ceramic crowns. The manipulation of the digital files registered with an intraoral scanner with software that allows its alignment (best-fit) and the performance boolean of operatio…

research product

Methodology in specimen fabrication for in vitro dental studies: Standardization of extracted tooth preparation

Background Specimen preparation for in vitro study suffers a general lack of methodological homogeneity, as well as a lack of uniformity in the materials selected for fabricating them. This situation prevents comparisons between studies. When a specimen is not of dental origin it is not possible to study adhesion or bonding techniques realistically. The objective is to design and implement a method of specimen preparation that permits universal standardization for use in in vitro studies. Material and Methods A metal stump of specified dimensions was designed and fabricated by hand. It was scanned, the data digitalized, perfecting and standardizing the dimensions. Ten human molars were adap…

research product

Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.

Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…

research product

Dental-gingival remodeling with BOPT no-prep veneers

Recent years have seen increasing demand for treatments aimed at improving dental esthetics. In this context, both patients and dentists prefer to preserve dental structures as far as possible; thanks to technological advances, especially in adhesive dentistry, new materials and minimally invasive techniques such as “no-prep” (no preparation) veneers have made this possible. Nevertheless, no-prep veneers have specific indications and suffer certain disadvantages. Objectives: This clinical case describes the rehabilitation of the upper anterior region by means of no-prep veneers, with BOPT (Biologically Oriented Preparation Technique) cervical margins. The patient had requested an aesthetic …

research product

In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®

Background It is necessary to know the in vitro behavior of different attachment systems to be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de-insertion cycles) was determined in vitro, evaluating two overdenture attachment systems (Locator® and OT Equator®). Material and methods The study used an implant replica compatible with the abutments of both systems. 10 Locator® and 10 OT Equator® attachments were screwed to the abutments. Nylon inserts were attached and tested, subjecting them to 14,600 insertion and de-insertion cycles (representing 10 years functional life) in axial direction. The universal test machine crosshead speed was 50 mm/min with a…

research product

Wear in Antagonist Teeth Produced by Monolithic Zirconia Crowns: A Systematic Review and Meta-Analysis

Background: The aim of this systematic review and meta-analysis was to determine the wear sustained in the natural antagonist tooth in cases of full-coverage fixed-base prosthetic restorations or monolithic zirconia tooth-supported crowns, as well as to determine the wear in the restoration itself, both in the short- and medium-term and considering the factors that may influence wear. Material and methods: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated wear in antagonist teeth in relation to fixed-prosthesis monolithic zirconia crowns. A total of 5 data…

research product

Facial scanning accuracy depending on the alignment algorithm and digitized surface area location: An in vitro study.

To measure the accuracy (trueness and precision) of a facial scanner depending on the alignment method and the digitized surface area location.Fourteen markers were adhered on a head mannequin and digitized using an industrial scanner (GOM Atos Q 3D 12 M; Carl Zeiss Industrielle Messtechnik GmbH). A control mesh was acquired. Subsequently, the mannequin was digitized using a facial scanner (Arc4; Bellus3D) (n = 30). The control mesh was delineated into 10 areas. Based on the alignment procedures, two groups were created: reference best fit (RBF group) and landmark-based best fit (LA group). The root mean square was used to calculate the discrepancy between the control mesh and each facial s…

research product

Traction test of temporary dental cements

Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear…

research product

Fracture Resistance of New Metal-Free Materials Used for CAD-CAM Fabrication of Partial Posterior Restorations

Background and Objectives: To evaluate in vitro the fracture resistance and fracture type of computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Discs were fabricated (10 &times

research product

Are Metal-Free Monolithic Crowns the Present of Prosthesis? Study of Mechanical Behaviour

Purpose: To analyze in vitro the mechanical behavior of five types of complete coverage crowns fabricated from different materials. Materials and methods: Seventy-five full coverage crowns were divided into five groups according to material: Group I, metal core with feldspathic ceramic covering (MC- control group)

research product

Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study

Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80). Medical histories were reviewed, and patients underwent oral examinations. Prosthetic clinical outcomes and patient well-being were registered using the Oral Health Impact…

research product

Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner.

Background The aim of this study was to compare a conventional technique (elastomeric impression material - EIM) and a digital technique (scanner digital model – SDM) on a six-analog master model (MM) to determine which was the most exact. Material and Methods Twenty impressions were taken of a master model (EIM) and twenty scanned impressions (SDM) (True Definition). A coordinate measuring machine (CMM) was used to measure the distances between adjacent analogues (1-2, 2-3, 3-4, 4-5, 5-6), intermittently positioned analogues (1-4, 3-6) and the most distal (1-6). Reference values were established from the master model, which were compared with the two impression techniques. The significance…

research product

What can we do with a dental avulsion? A multidisciplinary Clinical Protocol

Purpose The aim of this case report was to explain a multidisciplinary and conservative approach carrying out the replantation of an avulsed closed apex central incisor stored in dry conditions for a 16-hour period from the moment of trauma. Case report This report describes a case of a 28 year-old male who suffered contusion of the upper lip, avulsion of right upper central incisor, enamel cracks after trauma of left upper central incisor and upper left lateral incisor crown fracture due to an accident. Avulsed tooth was dry stored and it was replanted 16h after the trauma. The root was disinfected and the necrotic periodontal tissue removed, the endodontic treatment was done before replan…

research product

Peri-Implant Behavior of Tissue Level Dental Implants with a Convergent Neck

Introduction: The aim of this retrospective study was to analyze the radiographic peri-implant bone loss of bone level implants and tissue level implants with a convergent neck in screw-retained single crowns and in screw-retained fixed partial prostheses, after two years of functional loading. Materials and methods: The sample was divided into two groups according to their type: Group I: supracrestal implants with convergent transmucosal neck

research product

Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Patients.

Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator&reg

research product

Systematic review of chewing simulators : reality and reproducibility of in vitro studies

Background The aim of this systematic review was to analyze the types of human chewing simulator described in scientific literature. Material and Methods An electronic search was conducted in the databases PubMed, Embase and Scopus. The search strategy included 10 search terms: “in vitro”; “dental materials”; “shear strength”; “fatigue fracture”; “bite force”; “prosthetic materials”; “chewing simulator”; “chewing machine”; “simulated mastication”; and “dental wear simulator.” Two researchers worked independently to assess the titles and abstracts of the articles. The quality of the in vitro trials selected was evaluated by means of the Consolidated Standards of Reporting Trials scale. Resul…

research product