0000000000069920

AUTHOR

Jörgen Ekman

Mobility determination of lead isotopes in glass for retrospective radon measurements rad

In retrospective radon measurements, the 22-y half life of 210Pb is used as an advantage. 210Pb is often considered to be relatively immobile in glass after alpha recoil implanted by 222Rn progenies. The diffusion of 210Pb could, however, lead to uncertain wrong retrospective radon exposure estimations if 210Pb is mobile and can escape from glass, or lost as a result of cleaning-induced surface modification. This diffusion was studied by a radiotracer technique, where 209Pb was used as a tracer in a glass matrix for which the elemental composition is known. Using the ion guide isotope separator on-line technique, the 209Pb atoms were implanted into the glass with an energy of 39 keV. The di…

research product

Retention of Pb isotopes in glass surfaces for retrospective assessment of radon exposure

Abstract In recent years there has been increasing interest in radio-epidemiological techniques to retrospectively measure the radon dose exposure by determining the activity of 210Pb, the longest-lived 222Rn progeny, in glass surface layers. In this study the diffusion of 39 keV 209Pb+ ions implanted into glass using the IGISOL facility has been studied under conditions that mimic the recoil implantation of 210Pb from 222Rn. The resulting depth distributions of 209Pb were then measured after heat treatment in vacuum at different temperatures by a sputter erosion technique. The diffusion coefficient could be described by an Arrhenius equation D = D0exp(−H/kT) where D 0 = 0.30 - 0.24 + 1.14 …

research product

Mobility determination of lead isotopes in glass for retrospective radon measurements

In retrospective radon measurements, the 22-y half life of (210)Pb is used as an advantage. (210)Pb is often considered to be relatively immobile in glass after alpha recoil implanted by (222)Rn progenies. The diffusion of (210)Pb could, however, lead to uncertain wrong retrospective radon exposure estimations if (210)Pb is mobile and can escape from glass, or lost as a result of cleaning-induced surface modification. This diffusion was studied by a radiotracer technique, where (209)Pb was used as a tracer in a glass matrix for which the elemental composition is known. Using the ion guide isotope separator on-line technique, the (209)Pb atoms were implanted into the glass with an energy of …

research product

Application of ultra-fast timing techniques to the study of exotic and weakly produced nuclei

Ultra-fast time-delayed techniques have been recently applied in a number of studies where exotic nuclei were identified using advanced selection techniques. These include large Compton-suppressed Ge arrays, in-flight separators or recoil separators. Some of the new results are discussed in this presentation. Besides the results for $^{32}$Mg and $^{96}$Pd, they include the first determination of the half-life of the $8^+$ state in $^{80}$Ge, $T_1/2$ = 2.95(6) ns, and significantly more precise results for $^{51}$Mn (3680 keV level) and $^{48}$V (421 keV level), $T_1/2$ = 1760(40) ps and $T_1/2$ $\leq$ 135 ps, respectively. Development of new scintillators will steadily improve precision an…

research product