Hard X-Ray Response of Pixellated CdZnTe Detectors
In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm3 single crystals) have an anode layout based on an array of 256 pixels with a …
Development of a 3D CZT Spectrometer System with Digital Readout for Hard X/Gamma-Ray Astronomy
We report on the development and of a complete X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimensions (3D) and a digital electronics acquisition chain. The prototype is made by packing four linear modules, each composed of one 3D CZT sensors. Each sensors is realized using a single spectroscopic graded CZT crystal of about 20×20×5 mm3. An electrode structure consisting of 12 collecting anodes with a pitch of 1.6 mm and 3 drift strips between each pair of anodes for 48 strips (0.15 mm wide) on the anodic side was adopted. The cathode is made of 10 strips with a pitch of 2 mm and orthogonal to anode side strips. Since the reading of the …
Investigation on pixellated CZT detectors coupled with a low power readout ASIC
In this work, we investigated on the spectroscopic performances of two pixellated CZT detectors coupled with a custom low noise and low power readout ASIC. The detectors (10 x 10 x 1 mm3 and 10 x 10 x 2 mm3 single crystals) consist of an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 μm BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) characterized by a dynamic range from 10 keV to 100 keV, low power consumption (0.5 mW/channel) and low noise (150–500 electrons r.m.s.). The spectroscopic results point out the good energy resolution of both detectors at room temperature (5.8 % FWHM at 59.5 keV for the 1 mm thick detec…
Monte Carlo evaluation of a CZT 3D spectrometer suitable for a Hard X- and soft-γ rays polarimetry balloon borne experiment
Today, the measurement of the polarization status of cosmic sources high-energy' emission, is recognized as a key observational parameter to understand the active production mechanism and its geometry. Therefore, a mandatory requirement for new instrumentations operating in this energ.-y range will be to provide high sensitivity for polarimetric measurements. In this framework, we have presented the concept of a small high-performance imaging spectrometer optimized for polarimetry between 100 and 600 keV suitable for a stratospheric balloon-borne payload and as a pathfinder for a future satellite mission. The detector with 3D spatial resolution is based on a CZT spectrometer in a highly seg…
Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications
Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact and reliable detection systems. In this paper, we review the current status of research in the development of CdTe and CdZnTe detectors by a comprehensive survey on the material properties, the device characteristics, the different techniques for improving the overall detector…
Spectroscopic response and charge transport properties of CdZnTe detectors grown by the vertical Bridgman technique
In this work, we present the results of spectroscopic investigations on CdZnTe (CZT) detectors grown by the boron oxide encapsulated vertical Bridgman technique (1MEM-CNR, Parma, Italy). The detectors, with different thicknesses (1 and 2.5 mm), are characterized by the same electrode layout (gold electroless contacts): the anode is a central electrode (2 x 2 mm(2)) surrounded by a guard-ring electrode, while the cathode is a planar electrode covering the detector surface (4.1 x 4.1 mm(2)). The results of electrical investigations point out the low leakage currents of these detectors even at high bias voltages: 38 nA/cm(2) (T = 25 degrees C) at 10000 V/cm. The time stability and the spectros…
Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT
Recently, new high-resolution cadmium–zinc–telluride (CZT) drift strip detectors for room temperature gamma-ray spectroscopic imaging were developed by our group. The CZT detectors equipped with orthogonal anode/cathode collecting strips, drift strips and dedicated pulse processing allow a detection area of 6 × 20 mm2 and excellent room temperature spectroscopic performance (0.82% FWHM at 661.7 keV). In this work, we investigated the potentialities of these detectors for prompt gamma-ray spectroscopy (PGS) in boron neutron capture therapy (BNCT). The detectors, exploiting the measurement of the 478 keV prompt gamma rays emitted by 94% 7Li nuclides from the 10B(n, α)7…
Charge transport properties in CdZnTe detectors grown by the vertical Bridgman technique
Presently, a great amount of effort is being devoted to the development of CdTe and CdZnTe (CZT) detectors for a large variety of applications such as medical, industrial, and space research. We present the spectroscopic properties of some CZT crystals grown by the standard vertical Bridgman method and by the boron oxide encapsulated vertical Bridgman method, which has been recently implemented at IMEM-CNR (Parma, Italy). In this technique, the crystal is grown in an open quartz crucible fully encapsulated by a thin layer of liquid boron oxide. This method prevents contact between the crystal and the crucible, thereby allowing larger single grains with a lower dislocation density to be obta…
A deep study of the high–energy transient sky
This is an open access article. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds t…
Charge Transport Properties in CZT Detectors Grown by the Vertical Bridgman Technique
Great efforts are being presently devoted to the development of CdTe and CdZnTe detectors for a large variety of applications, such as medical, industrial, and space research. We present the spectroscopic properties of some CZT crystals grown by the standard vertical Bridgman method and by the boron oxide encapsulated vertical Bridgman method, which has been recently implemented at IMEM-CNR (Parma, Italy). By this technique the crystal is grown in an open quartz crucible fully encapsulated by a thin layer of liquid boron oxide. This method prevents contact between the crystal and the crucible thereby allowing larger single grains with a lower dislocation density to be obtained. Several mono…
High performance 3D CZT spectro-imager for BNCT-SPECT: preliminary characterization
The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell…
Measurements with a hybrid detector prototype composed of a MOS CCD and a CZT spectrometer
The scientific objectives of the future X-ray astronomy instruments require new type of focusing telescopes able to extend the observational range starting from 0.1 keV at least up to 100 keV to solve crucial question concerning the nature of the high energy emission. A challenging technology to extend the classical grazing incidence range to higher energy is today offered by the development of multilayer optics that are effective as X-ray concentrators between few keV up to 100 keV. A useful arrangement for this type of mission concept can foresee the soft (e.g. 0.1-10 keV) X-ray optics nested and coaxial with the hard-X mirrors. The focal plane of the telescope shall operate on a very wid…
A CdTe position sensitive spectrometer for hard X- and soft γ-ray polarimetry
Coded Imager and Polarimeter for High Energy Radiation (CIPHER) is a hard X- and soft gamma- ray spectroscopic and polarimetric coded mask telescope based on an array of Cadmium telluride microspectrometers. The position sensitive detector (PSD) will be arranged in 4 modules of 32 x 32 crystals, each of 2 x 2 mm(2) cross-section and 10 mm thickness giving a total active area of about 160 cm(2), operating over a wide energy range (similar to10 keV to 1 MeV). Each PSD module is obtained by aligning 32 linear arrays of micro-detectors each also containing the integrated analog front end electronics on a thin ceramic layer. The CIPHER instrument will be proposed for a balloon experiment, both i…
New Results on High-Resolution 3-D CZT Drift Strip Detectors
Intense research activities have been carry out in the development of room temperature gamma ray spectroscopic imagers, aiming to compete with the excellent energy resolution of high-purity germanium (HPGe) detectors (0.3 % FWHM at 662 keV) obtained after cryogenic cooling. Cadmium-zinc-telluride (CZT) detectors equipped with pixel, strip and virtual Frisch-grid electrode structures represented an appealing solution for room temperature measurements. In this work, we present the performance of new high-resolution CZT drift strip detectors (19.4 x 19.4 x 6 mm3), recently fabricated at IMEM-CNR of Parma (Italy) in collaboration with due2lab company (Reggio Emilia, Italy). The detectors, worki…
Characterization of a CZT focal plane small prototype for hard X-ray telescope
The promise of good energy and spatial resolution coupled with high efficiency and room temperature operation has fuelled a large international effort to develop cadmium zinc telluride (CZT) for hard X-ray applications. We are involved on the development of a hard X-ray telescope based on multilayer optics and focal plane detector operative in the 10-80 keV energy range. This telescope requires a high efficiency focal plane providing both fine spatial resolution and spectroscopy with a compact and robust design. This paper reports preliminary results on the characterization both in spectroscopic and spatial response of two small pixellated CZT detectors (10times10times1 mm3 and 10times10tim…
Development of a 3D CZT detector prototype for Laue Lens telescope
We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (similar to 19x8 mm(2) area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode side is segmented in 64 strips, that divide the crystal in 8 independent sensor (pixel), each composed by one collecting strip and 7 (one in common) adjacent drift strips. The drift strips are biased by a voltage divider, whereas the anode strips are held at ground. Furthermore, the cathode is divided in 4 horizontal strips for the reconstruction of the third interaction position coord…
Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.
In the last two decades, great efforts have been made in the development of 3D cadmium–zinc–telluride (CZT) detectors operating at room temperature for gamma-ray spectroscopic imaging. This work presents the spectroscopic performance of new high-resolution CZT drift strip detectors, recently developed at IMEM-CNR of Parma (Italy) in collaboration with due2lab (Italy). The detectors (19.4 mm × 19.4 mm × 6 mm) are organized into collecting anode strips (pitch of 1.6 mm) and drift strips (pitch of 0.4 mm) which are negatively biased to optimize electron charge collection. The cathode is divided into strips orthogonal to the anode strips with a pitch of 2 mm. Dedicated pulse processing analysis…