S. Capra
Digital pulse-shape analysis with a TRACE early silicon prototype
[EN] A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination. K.; 2014 Elsevier B.V. All rights reserved
The GALILEO γ-ray array at the Legnaro National Laboratories
Abstract GALILEO, a new 4 π high-resolution γ -detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital read-out chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy γ -ray transitions. In this work, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.
Conceptual design of the TRACE detector readout using a compact, dead time-less analog memory ASIC
[EN] The new TRacking Array for light Charged particle Ejectiles (TRACE) detector system requires monitorization and sampling of all pulses in a large number of channels with very strict space and power consumption restrictions for the front-end electronics and cabling. Its readout system is to be based on analog memory ASICs with 64 channels each that sample a View the MathML source window of the waveform of any valid pulses at 200 MHz while discarding any other signals and are read out at 50 MHz with external ADC digitization. For this purpose, a new, compact analog memory architecture is described that allows pulse capture with zero dead time in any channel while vastly reducing the tota…
Design of an integrated low-noise, low-power charge sensitive preamplifier for γ and particle spectroscopy with solid state detectors
The design of an integrated charge-sensitive preamplifier suitable for γ-ray spectroscopy is presented. It is fully integrated, except for the feedback resistor, and can drive directly a 50Ω cable with its low impedance output stage. It is designed in AMS 0.35µm technology and its small dimensions and low power consumption (10 mW) are optimized for multi-channel applications. It works both with germanium and silicon detectors for a large range of values of electrode and feedback capacitances. Its wide bandwidth ensures a risetime of 10 ns or less in most configurations. This characteristic makes the preamplifier suitable not only for high resolution spectroscopy but also for pulse-shape ana…