0000000000133118
AUTHOR
Christophe Mavon
Well GeHP detector calibration for environmental measurements using reference materials
International audience; A well-type detector installed in the Modane underground Laboratory (LSM) can combine both low background and high detection efficiency and it is well suited for the analysis of small amounts of environmental samples. Reference materials such as IAEA-447 (moss-soil), IAEA-RG-Th1 and IAEA-RG-U1 were used for the detector calibration, owing to a chemical composition close to those of the environmental samples. Nevertheless , the matrix effects and the true coincidence summing effects must be corrected from the full energy peak efficiency (FEPE). The FEPE was performed for a wide range of energy by a semi-empirical method using Monte Carlo simulation (MCNP6), intended f…
Spatial distribution of air kerma rate and impact of accelerating voltage on the quality of an ultra soft X-ray beam generated by a cold cathode tube in air
Abstract Ultrasoft X-ray characteristic aluminum K alpha line (Al Kα with energy of 1.5 keV) is used in radiobiological experiments to study the effect of radiation on biological matter. A simple method to generate a continuous beam of those X-ray radiations is to bombarding an aluminum target with accelerated electrons using high voltage (HV). In this work, by varying the HV we study the characteristics of a photon beam generated by means of a cold cathode transmission X-ray tube. The anode is a thin (16 μm) aluminum foil supported by a copper grid. The spatial distribution of air kerma is measured using gafchromic films of HD-810 calibrated with a parallel plate free-air ionization chambe…
Complexation des acides aminés basiques arginine, histidine et lysine avec l’ADN plasmidique en solution aqueuse : participation à la capture de radicaux sous irradiation X à 1,5 keV
L’environnement chimique de l’ADN en situation biologique est complexe notam-ment en raison de la presence d’histones, proteines nucleaires, associees en quantite approximativement egales a l’ADN pour former la chromatine. Les histones possedent de nombreux radicaux basiques arginine et lysine charges positivement et dont la majorite se trouve sur les chaines emergentes, l’ADN presente quant a lui des charges negatives sur ses groupements phosphates localises tout au long de la double helice. Dans cette etude, la complexite de la structure de la chromatine nucleaire est dans un premier temps mimee en solution aqueuse par la formation de complexes entre un ADN plasmidique sonde et les trois …
Benzene monitoring by micro-machined sensors with SnO2 layer obtained by using micro-droplet deposition technique
International audience; SnO2 thin layers were deposited by the way of the micro-droplet technique. The sensor substrate consisted of a thin membrane developed on oxidised silicon wafer. The sensing layers were deposited by means of the micro-droplet technique into thin layers of about 100 nm. Such devices were tested for benzene detection. The obtained results showed a very high sensitivity for this chemical compound since 500 ppb were detected. The results presented in this paper were not focused on the reactional mechanism of benzene detection but rather on the development of a cheap and sensitive sensor using sol-gel and micro-droplet processes. Since these layers were elaborated using s…
Determination of mass attenuation coefficient by numerical absorption calibration with Monte-Carlo simulations at 59.54 keV
Abstract This study presents a numerical method in order to determine the mass attenuation coefficient of a sample with an unknown chemical composition at low energy. It is compared with two experimental methods: a graphic method and a transmission method. The method proposes to realise a numerical absorption calibration curve to process experimental results. Demineralised water with known mass attenuation coefficient ( 0.2066 cm 2 g − 1 at 59.54 keV) is chosen to confirm the method. 0.1964 ± 0.0350 cm 2 g − 1 is the average value determined by the numerical method, that is to say less than 5% relative deviation compared to more than 47% for the experimental methods.