AUTHOR

O. Vilitis

Determination of Contact Potential Difference by the Kelvin Probe (Part I) I. Basic Principles of Measurements

Abstract Determination of electric potential difference using the Kelvin probe, i.e. vibrating capacitor technique, is one of the most sensitive measuring procedures in surface physics. Periodic modulation of distance between electrodes leads to changes in capacitance, thereby causing current to flow through the external circuit. The procedure of contactless, non-destructive determination of contact potential difference between an electrically conductive vibrating reference electrode and an electrically conductive sample is based on precise control measurement of Kelvin current flowing through a capacitor. The present research is devoted to creation of a new low-cost miniaturised measuremen…

research product

Cylindrical Cell-Based Refractometers to Analyse Biomedical Liquids

Compact device of high sensitivity for measurement of the refractive indices of both stationary and flowing liquids has been developed. This device can be used to analyse a variety of biomedical liquids: urine, serum protein. The refractive index (RI) is determined by measuring the deviation of a laser beam passing through a cylindrical cell containing the test liquid. In order to significantly improve the resolution and stability of RI measurements, the repeated reflections and refractions of the light beam travelling through the cylindrical cell are employed.

research product

Determination of Contact Potential Difference by the Kelvin Probe (Part II) 2. Measurement System by Involving the Composite Bucking Voltage

Abstract The present research is devoted to creation of a new low-cost miniaturised measurement system for determination of potential difference in real time and with high measurement resolution. Furthermore, using the electrode of the reference probe, Kelvin method leads to both an indirect measurement of electronic work function or contact potential of the sample and measurement of a surface potential for insulator type samples. The bucking voltage in this system is composite and comprises a periodically variable component. The necessary steps for development of signal processing and tracking are described in detail.

research product

Measurement of Low Concentration of Nanosized Objects Suspended in a Liquid Medium

The new optical scheme of refractometer with temperature stabilisation 10-2 °C is developed, which allows measuring a refractive index of the sample with accuracy not worse than 10-5; dependence of refraction index on concentration of SiO2 nanoparticles in liquid suspension is obtained within the framework of the research.

research product

Cylindrical Cuvette Light Refraction Measurements Technology to Analyse Biomedical Liquids

Compact device of high sensitivity for measurement of the refractive indices for both stationary and flowing liquids has been developed. This device can be used to analyse a variety of biomedical liquids: urine, serum protein. The refractive index (RI) is determined by measuring the deviation of a laser beam passing through a cylindrical cuvette containing the test liquid. In order to significantly improve the resolution and stability of RI measurements, the repeated reflections and refractions of the light beam travelling through the cylindrical cuvette are employed.

research product