0000000000135633
AUTHOR
ÁLvaro Zubizarreta-macho
Efficacy of removing Thermafil and GuttaCore from straight root canal systems using a novel non-surgical root canal re-treatment system : a micro-computed tomography analysis
The present study aims to evaluate the effectiveness of an XP-endo non-surgical root canal re-treatment system in removing both GuttaCore and Thermafil gutta-percha carrier-based root canal filling materials from straight root canal systems using micro-computed tomography (micro-CT) analysis. The study was performed on 20 single-rooted upper teeth, which were randomly allocated into the following study groups: Group A, Thermafil and AH Plus sealer (n = 10)
Prosthetically‐Driven Full‐Mouth Implant‐Supported Prostheses Using Guided Surgical Implant Planning with Composite Resin Markers: A Case Report
This report describes a prosthetically-driven implant planning method, guided by the alignment procedures between the cone beam computed tomography, intraoral digital scans, and digitized maxillary and mandibular interim complete dentures using intraoral composite resin markers as a common reference. The markers were attached to the keratinized oral mucosa of the edentulous ridges using cyanoacrylate and kept in place during the digitizing procedures. The technique provides a simpler and more economical alternative to conventional prosthetically-driven static implant planning methods.
Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study
Aim: To analyze the accuracy capability of two computer-aided navigation procedures for dental implant placement. Materials and Methods: A total of 40 dental implants were selected, which were randomly distributed into two study groups, namely, group A, consisting of those implants that were placed using a computer-aided static navigation system (n = 20) (guided implant (GI)) and group B, consisting of those implants that were placed using a computer-aided dynamic navigation system (n = 20) (navigation implant (NI)). The placement of the implants from group A was performed using surgical templates that were designed using 3D implant-planning software based on preoperative cone-beam computed…
Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Part I: Hard Tissues
Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading. Materials and Methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant b…
Effect of Computer-Aided Navigation Techniques on the Accuracy of Endodontic Access Cavities: A Systematic Review and Meta-Analysis
Simple Summary The endodontic access cavity is an essential step in the root canal treatment allowing the access and location of the root canal system. The inaccuracy during the endodontic access cavitie can lead to intraoperative complications such as missed root canals or root perforations, and hence affect the prognosis of the root canal treatment. The development of computer-aided static and dynamic navigation techniques has improved the accuracy of endodontic access cavities and root canal location; however, it is necessary a comparative analysis to clarify which of the computer-aided navigation system is more accurate. This systematic review and meta-analysis aims to clarify the root …
The Efficacy of Rotary, Reciprocating, and Combined Non-Surgical Endodontic Retreatment Techniques in Removing a Carrier-Based Root Canal Filling Material from Straight Root Canal Systems: A Micro-Computed Tomography Analysis
The aim of this study is to analyze and compare the efficacy of three non-surgical endodontic retreatment techniques in removing a carrier-based root canal filling material from straight root canal systems. The study was performed on 99 single-rooted extracted teeth using the ProTaper Gold endodontic rotary system up to the F2 file (Dentsply Maillefer, Baillagues, Switzerland), which were sealed with GuttaCore (Dentsply Maillefer, Ballaigues, Switzerland) and AH plus epoxy resin sealer (Dentsply DeTrey, Konstanz, Germany) and randomly assigned to the following non-surgical retreatment techniques: ProTaper Retreatment endodontic rotary instruments (D1&ndash
The influence of NiTi alloy on the cyclic fatigue resistance of endodontic files
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41)
An analysis in vivo of intracanal bacterial load before and after chemo-mechanical preparation: A comparative analysis of two irrigants and two activation techniques
Background: The goals of this randomized double-blind trial were to assess the antimicrobial activity in vivo of Sodium hypochlorite (NaOCl) vs. chlorhexidine gluconate (CHX) used in combination either with EndoActivator® or IRRI S® files in patients with apical periodontitis. Material and Methods: A total of 120 patients with apical periodontitis (in single or multiple root canals) were randomly assigned to the four irrigation protocols outlined below: Group A: 5.25% sodium hypochlorite (NaOCl) + EndoActivator®; Group B: 5.25% NaOCl + IRRI S® files; Group C: 2% chlorhexidine gluconate (CHX) + EndoActivator®; Group D: 2% CHX + IRRI S® files. Paper points were used to collect microbiological…
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The aim of this study was to analyze the effect of the taper and apical diameter of nickel&ndash
Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparations
The aim of this comparative study is to analyze the influence of drilling technique on the radiographic, thermographic, and geomorphometric effects of dental implant drills and osteotomy site preparations. One hundred and twenty osteotomy site preparations were performed on sixty epoxy resin samples using three unused dental implant drill systems and four drilling techniques performed with a random distribution into the following study groups: Group A: drilling technique performed at 800 rpm with irrigation (n = 30)
Endodontic re-treatment and restorative treatment of a dens invaginatus type II through new technologies
Background The complex anatomy of dens invaginatus makes access cavity to root canal system difficult, which has an impact on the prognosis of these teeth. A novel technique, based on new technologies, is proposed to make access cavity conservative and guided with minimal dental structure lost. Material and Methods This case report shows the root canal retreatment and the endodontic surgery of a dens invaginatus type II in a left lateral upper incisor previously treated which was affected by a chronic apical abscess and an apical fracture. A Cone Beam Computed Tomography was performed to better diagnosis the dental anatomy. An intraoral scan was performed to get a digital 3D model. A comput…
Efficacy of Computer-Aided Static Navigation Technique on the Accuracy of Endodontic Microsurgery. A Systematic Review and Meta-Analysis
The aim of this systematic review and meta-analysis was to analyze the efficacy of the computer-aided static navigation technique on the accuracy of root apex location in endodontic microsurgery. Material and Methods: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated the apex location rate of the computer-aided static navigation techniques applied to endodontic microsurgery. A total of four databases were consulted in the literature search: Pubmed-Medline, Scopus, Cochrane, and Web of Science. After eliminating duplicated articles and applying the inclusio…
Comparative Analysis of Peri-Implant Bone Loss in Extra-Short, Short, and Conventional Implants. A 3-Year Retrospective Study
Objective: To evaluate the influence of implant length on marginal bone loss, comparing implants of 4 mm, 6 mm, and >
Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Procedure for Endodontic Access Cavities: An In Vitro Study
: Purpose: To analyze the accuracy of two computer-aided navigation techniques to guide the performance of endodontic access cavities compared with the conventional access procedure. Materials and Methods: A total of 30 single-rooted anterior teeth were selected, which were randomly distributed into three study groups: Group A&mdash
Comparative Analysis of Root Canal Dentin Removal Capacity of Two NiTi Endodontic Reciprocating Systems for the Root Canal Treatment of Primary Molar Teeth. An In Vitro Study
The objective of the present study was to evaluate and compare the dentin removal capacity of Endogal Kids and Reciproc Blue NiTi alloy endodontic reciprocating systems for root canal treatments in primary second molar teeth via a micro-computed tomography (micro-CT) scan. Materials and Methods: Sixty root canal systems in fifteen primary second molar teeth were chosen and classified into one of the following study groups: A: EK3 Endogal Kids (n = 30) (EDG) and B. R25 Reciproc Blue (n = 30) (RB). Preoperative and postoperative micro-CT scans were uploaded into image processing software to analyze the changes in the volume of root canal dentin using a mathematical algorithm that enabled prog…
Novel Digital Measurement Technique to Analyze the Palatine Suture Expansion after Palatine Rapid Maxillary Expansion Technique
The aim of the study was to validate a novel digital measurement method to quantify the volume of the midpalatal suture after rapid maxillary expansion (RME). Material and methods: Eight patients with maxillary skeletal transverse deficiency were submitted to palatine suture expansion using the McNamara orthodontic appliance during a period of nine months. After 30 days of treatment, all patients were exposed postoperatively to a cone-beam computed tomography (CBCT) scan. Afterwards, the scans were uploaded into the three-dimensional orthodontic-planning software to allow the volumetric assessment of the palatine suture expansion through palatine rapid maxillary expansion using a McNamara a…
Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model
Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodont…
A Novel Digital Technique for Measuring the Accuracy of an Indirect Bonding Technique Using Fixed Buccal Multibracket Appliances
The aim of this study was to analyze the accuracy and predictability of the indirect bonding technique of fixed buccal multibracket appliances using a customized iterative closest point algorithm. Materials and Methods: A total of 340 fixed buccal multibracket appliances were virtually planned and bonded on 34 experimental anatomically based acrylic resin models by using orthodontic templates designed and manufactured to indirectly bond the fixed buccal multibracket appliances. Afterwards, the models were submitted to a three-dimensional impression technique by an intraoral scanner, and the standard tessellation language digital files from the virtual planning and the digital impression wer…
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10)
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
Survival Rate and Prosthetic and Sinus Complications of Zygomatic Dental Implants for the Rehabilitation of the Atrophic Edentulous Maxilla: A Systematic Review and Meta-Analysis
Simple Summary Zygomatic dental implants have been proposed as an alternative to atrophic total edentulous maxillae rehabilitation with the necessity of bone grafting procedures. However, surgical, prosthetic, and maxillary sinus complications have been associated with this surgical procedure. Therefore, it is necessary to produce a systematic review and meta-analysis that provides evidence associated with the prognosis when using zygomatic dental implants as an alternative to atrophic total edentulous maxillae rehabilitation. Abstract The aim of this systematic review and meta-analysis was to analyze and compare the survival rate and prosthetic and sinus complications of zygomatic dental i…
What can we do with a dental avulsion? A multidisciplinary Clinical Protocol
Purpose The aim of this case report was to explain a multidisciplinary and conservative approach carrying out the replantation of an avulsed closed apex central incisor stored in dry conditions for a 16-hour period from the moment of trauma. Case report This report describes a case of a 28 year-old male who suffered contusion of the upper lip, avulsion of right upper central incisor, enamel cracks after trauma of left upper central incisor and upper left lateral incisor crown fracture due to an accident. Avulsed tooth was dry stored and it was replanted 16h after the trauma. The root was disinfected and the necrotic periodontal tissue removed, the endodontic treatment was done before replan…
Peri-Implant Behavior of Tissue Level Dental Implants with a Convergent Neck
Introduction: The aim of this retrospective study was to analyze the radiographic peri-implant bone loss of bone level implants and tissue level implants with a convergent neck in screw-retained single crowns and in screw-retained fixed partial prostheses, after two years of functional loading. Materials and methods: The sample was divided into two groups according to their type: Group I: supracrestal implants with convergent transmucosal neck
Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files
This article belongs to the Special Issue Innovations in Endodontic Dentistry.
A comparison of the marginal adaptation of composite overlays fabricated with silicone and an intraoral scanner
Background Intraoral scanners have been developing during last years. The aim of this study was to know if digital impressions achieve a marginal adaptation in overlays as well as conventional impressions with silicone. Material and methods Sixty-two extracted molars were selected. The samples were prepared for MOD overlays. The teeth were divided into two groups (n=31). Group 1: impressions were made with silicone (Express™ Impression, 3M ESPE) and overlays were manufactured with Sinfony composite (3M ESPE) by the laboratory technician. Group 2: impressions were taken with the scanner True Definition (TD, 3M ESPE) and under Lava Ultimate CAD/CAM Restorative composite (3M ESPE) were produce…
Failure Rate, Marginal Bone Loss, and Pink Esthetic with Socket-Shield Technique for Immediate Dental Implant Placement in the Esthetic Zone. A Systematic Review and Meta-Analysis
Simple Summary The socket-shield technique has been proposed for preserving the bone ridge and surrounding soft tissues with immediate implantation in the extraction socket, maintaining the buccal wall fragment of the dental root. However, the socket-shield technique has not been compared with the conventional technique for immediate dental implant placement in the esthetic zone regarding the failure rate, marginal bone loss, and pink esthetic. Therefore, it is necessary to develop a systematic review and meta-analysis that provides evidence associated with the prognosis when using the socket-shield technique compared to the conventional technique. Abstract Aim: To compare the failure rate,…