0000000000147187

AUTHOR

Paola Fattibene

Transferability of ASTM/NIST alanine–polyethylene recipe at ISS

Abstract Alanine–polyethylene solid state dosimeters were prepared at Istituto Superiore di Sanita (ISS) following the recipe proposed by National Institute of Standards and Technology (NIST) with the goal of testing its transferability. Dosimeters were prepared using 95% alanine and 5% polyethylene, by weight. They are rugged and of increased sensitivity, repeatability and reproducibility as respect to the ISS alanine-paraffin pellets. Reproducibility of about 1% was obtained at 10 Gy and at 3 Gy if one single pellet or a stack of five dosimeters were used, respectively.

research product

Is dust a suitable material for retrospective personal dosimetry?

This work investigates the feasibility of using silicates contained in dust for retrospective individual dosimetry in case of a radiation accident or a radiological attack involving people not wearing physical dosimeters. It is well known that minerals (silicates) can be used for dosimetry and dust already plays an important role in the field of food irradiation detection using luminescence techniques as described in the European Standards (EN 13751 and EN 1788). This paper explores the feasibility of conducting retrospective personal dosimetry on the basis of thermoluminescence analysis of silicates extracted from dust on objects that people usually wear (e.g. jewelry, watches, keys and co…

research product

Uncertainty on radiation doses estimated by biological and retrospective physical methods

International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…

research product

EPR dosimetry intercomparison using smart phone touch screen glass

International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…

research product

Planning a new international comparison on EPR dosimetry with tooth enamel: a EURADOS WG10 proposal

ntroduction L-a-alanine has aroused considerable interest for use in radiation ESR dosimetry. In this work, we examined the energy response of alanine ESR films in the low energy X-photon energy range between 1 keV and 40 keV. Dose measurements through a reference ionization chamber and a semiconductor detection system were also performed to complement ESR measurements. Methods Commercial alanine ESR films were used. All ESR signal measurements were also done using an XBand (9.7 GHz) Bruker spectrometer. The dosimeters were irradiated at the "Livio Scarsi" Laboratory (LAX) of the University of Palermo, where X-ray beams in the 1–40 keV energy range are produced using a Seifert SN60 tube. Re…

research product

REVIEW OF RETROSPECTIVE DOSIMETRY TECHNIQUES FOR EXTERNAL IONISING RADIATION EXPOSURES

The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic re…

research product

EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…

research product

The 4th international comparison on EPR dosimetry with tooth enamel

This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated s…

research product

Pulsed EPR analysis of tooth enamel samples exposed to UV and gamma-radiations

Abstract The electron paramagnetic resonance (EPR) spectroscopy is widely applied for retrospective dosimetric purposes by means of quantitative detection of radicals in tooth enamel and bone samples. In this work we report a study by cw and pulsed EPR on two samples of human tooth enamel respectively irradiated by UV (254 nm) and γ-exposed. The continuous wave (cw) EPR spectra have shown the usual presence in both samples of two types of CO 2 − radicals, with axial and orthorombic g tensors. We have obtained the electron spin echo detected EPR (ED-EPR) spectra at 80 K of the two samples, and we have shown that they are suitable to mark the difference between the effects produced by the dif…

research product

An EPR method for discriminating radiation beams in ammonium tartrate and tooth enamel

The radiation linear energy transfer (LET), which is the energy released by ionizing radiation per path unit, arouses great scientific interest because the biological damage produced by ionizing radiation in tissues is strictly related to LET. Radiation beams with different LETs will cause different spatial energy distribution and therefore different effects inside matter. In the last twenty years the EPR spectroscopy has become a valuable dosimetric tool. This technique allows absorbed dose measurements through the detection of free radicals produced by ionizing radiation in organic and/or inorganic compounds. In this work we have analyzed the possibility of using the acquisition of two co…

research product