Modifications in Ventricular Fibrillation and Capture Capacity Induced by a Linear Radiofrequency Lesion
[EN] Introduction and objectives: An analysis was made of the effects of a radiofrequency-induced linear lesion during ventricular fibrillation and the capacity to capture myocardium through high-frequency pacing. Methods: Using multiple epicardial electrodes, ventricular fibrillation was recorded in 22 isolated perfused rabbit hearts, analyzing the activation maps upon applying trains of stimuli at 3 different frequencies close to that of the arrhythmia: a) at baseline; b) after radio-frequency ablation to induce a lesion of the left ventricular free wall (length=10 [1] mm), and c) after lengthening the lesion (length=23 [2] mm). Results: Following lesion induction, the regularity of the r…
Modificaciones de la fibrilación ventricular y de la capacidad de captura inducidas por una lesión lineal con radiofrecuencia
Resumen Introduccion y objetivos Analizar los efectos, en la fibrilacion ventricular y en la capacidad de capturar al miocardio mediante estimulacion a frecuencias rapidas, de una lesion lineal producida con radiofrecuencia. Metodos En 22 corazones de conejo aislados y perfundidos, se utilizaron electrodos multiples epicardicos para registrar la fibrilacion ventricular. Se analizaron los mapas de activacion al aplicar trenes de estimulos a tres frecuencias distintas, cercanas a las de la arritmia, en tres situaciones: a) basalmente; b) tras producir con radiofrecuencia una lesion en la pared libre del ventriculo izquierdo (longitud, 10 ± 1 mm), y c) tras ampliar su extension (longitud, 23 ±…
A novel multielectrode for epicardial recording with temperature control based in Peltier cells
Electrophysiological parameters of the myocardium are influenced by temperature. Working with experimental models of isolated heart, the analysis of modulating effect exerted by local changes of temperature can provide some information about the mechanisms of certain arrhythmias and their electrophysiological bases, such as ventricular fibrillation. Conventional multiple electrodes do not seem to be appropriate, being necessary the development of specific devices. The design and implementation of a device adapted to these requirements is presented in this paper. This is a multi-electrode able to reproduce located and controlled conditions of hypothermia and hyperthermia, in a determined are…
2D Isochronal Correlation Method to Detect Pacing Capture during Ventricular Fibrillation
During ventricular fibrillation (VF), a portion of myocardial tissue can be captured by pacing at a rate near the fibrillation rate. Interruption of ventricular fibrillation can be favored by achieving stable myocardial capture, lowering the energy required for electrical cardioversion. Existence of myocardial capture during electrical stimulation is determined by visual inspection of electrograms (EGM) by an experienced observer. The objective of this work is the development of a semi-automatic method for the detection of myocardial capture based on the 2D correlation of isochronal maps. In 4 isolated rabbit hearts VF was induced by ventricular pacing with an increasing rate. An array of 1…
Experimental study on the effects of physical training on the defibrillation threshold
Background: Chest compression artifacts during cardiopulmonary resuscitation (CPR) deteriorate the rhythm diagnosis of automated external defibrillators (AED). Cardiopulmonary resuscitation must therefore be interrupted for a reliable shock/no-shock decision. However, these hands-off intervals adversely affect the defibrillation success, and, in addition, pauses in chest compressions compromise circulation. An accurate diagnosis of the rhythmwhile performing CPR is therefore needed to minimize these hands-off intervals. Methods: The characteristics of the CPR artifact are very variable, and the artifact presents an important spectral overlap with human cardiac arrest rhythms. Consequently, …