0000000000165655

AUTHOR

Jukka S. Jurvelin

showing 10 related works from this author

Volumetric changes of articular cartilage during stress relaxation in unconfined compression

2000

The time-dependent lateral expansion and load relaxation of cartilage cylinders subjected to unconfined compression were simultaneously recorded. These measurements were used to (1) test the assumption of incompressibility for articular cartilage, (2) measure the Poisson's ratio of articular cartilage in compression and (3) investigate the relationship between stress relaxation and volumetric change. Mechanical tests were performed on fetal, calf, and adult humeral head articular cartilage. The instantaneous Poisson's ratio of adult cartilage was 0.49+/-0.08 (mean+S.D.), thus confirming the assumption of incompressibility for this tissue. The instantaneous Poisson's ratio was significantly …

Cartilage ArticularAgingTime FactorsMaterials scienceBiomedical EngineeringBiophysicsArticular cartilageIn Vitro TechniquesLateral expansionPoisson distributionStress (mechanics)symbols.namesakeFetusPressuremedicineStress relaxationAnimalsOrthopedics and Sports MedicineCartilageRehabilitationAnatomyHumerusCompression (physics)Poisson's ratioBiomechanical Phenomenamedicine.anatomical_structureAnimals NewbornsymbolsCattleStress MechanicalBiomedical engineeringJournal of Biomechanics
researchProduct

Bone mineral density of the proximal femur after hip resurfacing arthroplasty: 1-year follow-up study

2011

Abstract Background Hip resurfacing arthroplasty (HRA) is considered a bone-preserving procedure and may eliminate proximal femoral stress shielding and osteolysis. However, in addition to implant-related stress-shielding factors, various patient-related factors may also have an effect on bone mineral density (BMD) of the proximal femur in patients with HRA. Thus, we studied the effects of stem-neck angle, demographic variables, and physical functioning on the BMD of the proximal femur in a one-year follow-up. Methods Thirty three patients (9 females and 24 males) with a mean (SD) age of 55 (9) years were included in the study. BMD was measured two days and 3, 6, and 12 months postoperative…

MaleTime Factorslcsh:Diseases of the musculoskeletal systemBone densityArthroplasty Replacement Hipmedicine.medical_treatmentdual energy X-ray absorptiometry02 engineering and technologySeverity of Illness IndexOsteoarthritis HipAbsorptiometry Photon0302 clinical medicineBone DensityOrthopedics and Sports MedicineFemurProspective StudiesFinlandstress shielding2. Zero hungerBone mineral030222 orthopedicsmedicine.diagnostic_teststem-neck angleMiddle AgedStress shieldingHip resurfacingREPLACEMENTTreatment Outcomemedicine.anatomical_structureFemaleResearch Articlebone remodeling dual energy X-ray absorptiometrymusculoskeletal diseasesmedicine.medical_specialtyeducation0206 medical engineering03 medical and health sciencesFemoral headPOSTERIOR APPROACHRheumatologymedicineHumansFemurPRESERVATIONbone remodelingNECKDual-energy X-ray absorptiometrybusiness.industry3126 Surgery anesthesiology intensive care radiology020601 biomedical engineeringArthroplastySurgeryLogistic Models5-YEARMODESABSORPTIOMETRYFEMORAL-HEADlcsh:RC925-935businessNuclear medicineFollow-Up StudiesBMC Musculoskeletal Disorders
researchProduct

Quantification of Bone Density of the Proximal Femur After Hip Resurfacing Arthroplasty—Comparison of Different DXA Acquisition Modes

2010

Total hip arthroplasty (THA) is a traditional operative procedure in the treatment of osteoarthritis. The hip resurfacing arthroplasty (HRA) provides an alternative to the THA for young active patients. HRA is a bone-preserving procedure eliminating the problem of proximal femoral stress shielding and osteolysis associated to THA. Unfortunately, there is no standardized methodology to monitor the quality of bone after HRA. In this study, areal bone mineral density (BMD) in the operated hip (10 regions of interests [ROIs] of 34 volunteered HRA patients) was measured using Lunar Prodigy dual-energy X-ray absorptiometry, and the agreement of a standard (dual femur) and an orthopedic (orthopedi…

Malemusculoskeletal diseasesmedicine.medical_specialtyOsteolysisBone densityArthroplasty Replacement HipEndocrinology Diabetes and Metabolismmedicine.medical_treatment030209 endocrinology & metabolismOsteoarthritis HipStatistics Nonparametric03 medical and health sciencesAbsorptiometry Photon0302 clinical medicineBone DensitymedicineHumansRadiology Nuclear Medicine and imagingOrthopedics and Sports MedicineFemurFemurBone mineral030222 orthopedicsbusiness.industryReproducibility of ResultsMiddle AgedStress shieldingmedicine.diseaseArthroplastyHip resurfacingOrthopedic surgeryFemaleRadiologyNuclear medicinebusinessJournal of Clinical Densitometry
researchProduct

Influence of Different DXA Acquisition Modes on Monitoring the Changes in Bone Mineral Density After Hip Resurfacing Arthroplasty

2011

Dual-energy X-ray absorptiometry (DXA) is a technique enabling the measurement of bone mineral density (BMD) around prostheses after hip resurfacing arthroplasty (HRA). In this study, we evaluated the consistency of different DXA acquisition modes with 33 patients who had undergone HRA. Patients were scanned with DXA immediately after surgery and at 3-, 6-, and 12-mo time points. All the patients were scanned with dual femur and orthopedic hip acquisition modes and analyzed using 10-region ROI model. With both acquisition modes, a statistically significant decrease (p0.05, Wilcoxon's test) in BMD at 3mo was revealed in 3 ROIs, located to upper and lateral upper femur. Both acquisition modes…

Malemusculoskeletal diseasesmedicine.medical_specialtyRotationArthroplasty Replacement HipEndocrinology Diabetes and Metabolismmedicine.medical_treatmentStatistics NonparametricBone remodeling03 medical and health sciencesAbsorptiometry Photon0302 clinical medicineBone DensitymedicineHumansRadiology Nuclear Medicine and imagingOrthopedics and Sports MedicineFemurFemurFemoral neck030203 arthritis & rheumatologyBone mineral030222 orthopedicsProximal femurbusiness.industryta3141Middle Agedmusculoskeletal systemHip resurfacingArthroplastymedicine.anatomical_structureOrthopedic surgeryFemaleHip JointRadiologybusinessNuclear medicineJournal of Clinical Densitometry
researchProduct

NMR relaxation times of trabecular bone—reproducibility, relationships to tissue structure and effects of sample freezing

2010

Nuclear magnetic resonance (NMR) spectroscopy provides a potential tool for non-invasive evaluation of the trabecular bone structure. The objective of this study was to determine the reproducibility of the NMR relaxation parameters (T(2), Carr-Purcel-T(2), T(1ρ)) for fat and water and relate those to the structural parameters obtained by micro-computed tomography (μCT). Especially, we aimed to evaluate the effect of freezing on the relaxation parameters. For storing bone samples, freezing is the standard procedure during which the biochemical and cellular organization of the bone marrow may be affected. Bovine trabecular bone samples were stored at -20 °C for 7 days and measured by NMR spec…

ReproducibilityMagnetic Resonance SpectroscopyTime FactorsRotationTibiaRadiological and Ultrasound TechnologyChemistryCoefficient of variationRelaxation (NMR)Reproducibility of ResultsWaterX-Ray MicrotomographyNuclear magnetic resonance spectroscopyTrabecular boneNuclear magnetic resonancemedicine.anatomical_structureAdipose TissueRelaxation rateFreezingmedicineAnimalsCattleRadiology Nuclear Medicine and imagingBone marrowSpectroscopyPhysics in Medicine and Biology
researchProduct

Importance of Patella, Quadriceps Forces, and Depthwise Cartilage Structure on Knee Joint Motion and Cartilage Response During Gait

2015

In finite-element (FE) models of the knee joint, patella is often omitted. We investigated the importance of patella and quadriceps forces on the knee joint motion by creating an FE model of the subject's knee. In addition, depthwise strains and stresses in patellar cartilage with different tissue properties were determined. An FE model was created from subject's magnetic resonance images. Knee rotations, moments, and translational forces during gait were recorded in a motion laboratory and used as an input for the model. Three material models were implemented into the patellar cartilage: (1) homogeneous model, (2) inhomogeneous (arcadelike fibrils), and (3) random fibrils at the superficia…

AdultCartilage ArticularMalemusculoskeletal diseasesquadricepsMaterials science0206 medical engineeringShear forceBiomedical Engineering02 engineering and technologyOsteoarthritisKnee Jointmedicine.disease_causegaitModels BiologicalQuadriceps MuscleWeight-bearingWeight-Bearingknee joint03 medical and health sciences0302 clinical medicineTensile StrengthPhysiology (medical)Collagen networkfinite-element modelsmedicineHumansComputer SimulationRange of Motion Articularta315Orthodonticsta114Cartilage030229 sport sciencesmusculoskeletal systemmedicine.disease020601 biomedical engineeringmedicine.anatomical_structurepatellaPatellaStress MechanicalRange of motionhuman activitiesMuscle ContractionJournal of Biomechanical Engineering
researchProduct

Changes in collagen cross-linking of articular cartilage are revealed by spectral reflectance imaging

2012

Excessive cross-linking of collagen during aging may contribute to degeneration of articular cartilage. Traditionally, the amount of cross-links is derived by using destructive high-performance liquid chromatography (HPLC). However, a sensitive, non-destructive method could help to evaluate tissue integrity, including cross-links. We increased collagen cross-linking in bovine articular cartilage by controlled threose incubation. During the incubation, optical spectral reflectance images of the samples were captured and related to HPLC results using regression analysis. Significant correlations with reflectance and cross-links were observed. When further developed the optical method may enab…

chemistry.chemical_compoundCollagen cross linkingThreoseChemistryIn vivoArticular cartilageReflectivityOptical reflectionBiomedical engineering2012 25th IEEE International Symposium on Computer-Based Medical Systems (CBMS)
researchProduct

Computed tomography detects changes in contrast agent diffusion after collagen cross-linking typical to natural aging of articular cartilage

2011

SummaryObjectiveThe effect of threose-induced collagen cross-linking on the mechanical and diffusive properties of cartilage was investigated in vitro. In particular, we investigated the potential of Contrast Enhanced Computed Tomography (CECT) to detect changes in articular cartilage after increased collagen cross-linking, which is an age-related phenomenon.MethodsOsteochondral plugs (Ø=6.0mm, n=28) were prepared from intact bovine patellae (n=7). Two of the four adjacent samples, prepared from each patella, were treated with threose to increase the collagen cross-linking, while the other two specimen served as paired controls. One sample pair was mechanically tested and then mechanically …

Cartilage ArticularAging0206 medical engineeringBiomedical EngineeringContrast MediaMineralogy02 engineering and technologyOsteoarthritisArginineDiffusion03 medical and health scienceschemistry.chemical_compound0302 clinical medicineRheumatologyCollagen networkIoxaglic AcidmedicineAnimalsOrthopedics and Sports MedicineAmino AcidsPentosidineComputed tomography030203 arthritis & rheumatologyPyridinolinebiologyThreoseChemistryLysineCartilageCartilage agingDelayed Gadolinium Enhanced Magnetic Resonance Imaging of CartilagePatellamedicine.diseaseCartilage injury020601 biomedical engineeringHindlimbContrast agentmedicine.anatomical_structureProteoglycanCase-Control Studiesbiology.proteinCattleCollagenTetrosesTomography X-Ray ComputedCross-linkingBiomedical engineeringOsteoarthritis and Cartilage
researchProduct

Nondestructive fluorescence-based quantification of threose-induced collagen cross-linking in bovine articular cartilage.

2012

Extensive collagen cross-linking affects the mechanical competence of articular cartilage: it can make the cartilage stiffer and more brittle. The concentrations of the best known cross-links, pyridinoline and pentosidine, can be accurately determined by destructive high-performance liquid chromatography (HPLC). We explore a nondestructive evaluation of cross-linking by using the intrinsic fluorescence of the intact cartilage. Articular cartilage samples from bovine knee joints were incubated in threose solution for 40 and 100 h to increase the collagen cross-linking. Control samples without threose were also prepared. Excitation-emission matrices at wavelengths of 220 to 950 nm were acquir…

Cartilage Articularmedicine.medical_specialtyCollagen cross linkingBiomedical EngineeringArticular cartilageIn Vitro Techniquesta3111Biomaterialschemistry.chemical_compoundmedicineAnimalsStatistical analysisThreoseCartilagefood and beveragesmusculoskeletal systemFluorescenceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryCross-Linking ReagentsSpectrometry Fluorescencemedicine.anatomical_structurechemistryBiophysicsCattleCollagenTetrosesJournal of biomedical optics
researchProduct

Diffusion of ionic and non-ionic contrast agents in articular cartilage with increased cross-linking--contribution of steric and electrostatic effect…

2013

Abstract Objective To investigate the effect of threose-induced collagen cross-linking on diffusion of ionic and non-ionic contrast agents in articular cartilage. Design Osteochondral plugs (O=6mm) were prepared from bovine patellae and divided into two groups according to the contrast agent to be used in contrast enhanced computed tomography (CECT) imaging: (I) anionic ioxaglate and (II) non-ionic iodixanol. The groups I and II contained 7 and 6 sample pairs, respectively. One of the paired samples served as a reference while the other was treated with threose to induce collagen cross-linking. The equilibrium partitioning of the contrast agents was imaged after 24h of immersion. Fixed char…

Steric effectsCartilage ArticularStatic ElectricityBiomedical EngineeringBiophysicsIonic bondingContrast Mediata3111Diffusionchemistry.chemical_compoundmedicineAnimalsPentosidineta315PyridinolinebiologyThreoseCartilageta3141Iodixanolmedicine.anatomical_structureProteoglycanchemistrybiology.proteinBiophysicsCattleCollagenTomography X-Ray ComputedBiomedical engineeringmedicine.drugMedical engineeringphysics
researchProduct