0000000000179967
AUTHOR
Agustín Pascual-moscardó
Correction: Mechanical properties of provisional dental materials: A systematic review and meta-analysis.
Provisional restorations represent an important phase during the rehabilitation process, knowledge of the mechanical properties of the available materials allows us to predict their clinical performance. At present, there is no systematic review, which supports the clinicians’ criteria, in the selection of a specific material over another for a particular clinical situation. The purpose of this systematic review and meta-analysis was to assess and compare the mechanical properties of dimethacrylates and monomethacrylates used in fabricating direct provisional restorations, in terms of flexural strength, fracture toughness and hardness. This review followed the PRISMA guidelines. The searche…
Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch
Abstract Statement of problem The accuracy of digital scanners is acceptable for scanning a complete dental arch. However, whether that accuracy is sufficient for only 1 tooth within the dental scan of a complete dental arch is unclear. Purpose The purpose of this in vitro study was to evaluate and compare the accuracy of 4 intraoral scanners on a complete dental arch and on prepared teeth digitally isolated from the digital scan in terms of trueness and precision. Material and methods A model of a complete dental arch with tooth preparations was scanned 40 times with each of the 4 digital scanners. Their accuracy was evaluated by using 3-dimensional (3D) software to compare the test models…
Effect of retention design of artificial teeth and implant-supported titanium CAD-CAM structures on fracture resistance
Background For implant-supported hybrid prostheses, high mastication forces and reduced acrylic resin thickness over a metal substructure often cause failures arising from tooth or resin fractures. To assay fracture resistance of artificial teeth and resin in implant-supported hybrid prostheses in relation to the titanium structure and retention design supporting teeth. Material and Methods 40 specimens bearing incisors were divided into four groups according to the titanium structure supporting the teeth and the type of load force applied: Group I (Control; n=10): Application of static loading to ten incisors set over a metal structure with internal retention. Group II (Control; n=10): App…
In vivo evaluation of three-dimensional of volumetric changes using a CAD/CAM chair-side system : technical procedure
An intraoral digital scanner in combination with specialized three-dimensional surface analysis software monitors volumetric changes to soft tissues or dental restorations. This technology can evaluate the success of a specific technique or medium- or long-term clinical outcomes in both clinical and research situations. This article describes how this technology was used to provide immediate chair-side data analysis without the help of specialized laboratory support. Key words:Intraoral scanner, CAD-CAM, best fit-method, surface tessellation language.
Mechanical properties of provisional dental materials: A systematic review and meta-analysis
Provisional restorations represent an important phase during the rehabilitation process, knowledge of the mechanical properties of the available materials allows us to predict their clinical performance. At present, there is no systematic review, which supports the clinicians' criteria, in the selection of a specific material over another for a particular clinical situation. The purpose of this systematic review and meta-analysis was to assess and compare the mechanical properties of dimethacrylates and monomethacrylates used in fabricating direct provisional restorations, in terms of flexural strength, fracture toughness and hardness. This review followed the PRISMA guidelines. The searche…
A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally invasive approach.
Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…
Accuracy of four digital scanners according to scanning strategy in complete-arch impressions.
STATEMENT OF PROBLEM:Although there are specific and general digital scanning guidelines depending on the system used, it is important to have the necessary flexibility in the acquisition of three-dimensional (3D) images to adapt to any clinical situation without affecting accuracy. PURPOSE:The purpose of this in vitro study was to identify and compare the scanning strategy with the greatest accuracy, in terms of trueness and precision, of four intraoral scanners in the impression of a complete dental arch. MATERIAL AND METHODS:Four digital scanners were evaluated with a 3D measuring software, using a highly accurate reference model obtained from an industrial scanner as a comparator. Four …
¿Son los adhesivos dentinarios una opción válida para el tratamiento de la sensibilidad cervical dentinaria?
espanolEl objetivo de este trabajo es evaluar la capacidad in vitro de sellar tubulos dentinarios y reducir la permeabilidad dentinaria que tienen catorce productos propuestos para el tratamiento de la sensibilidad cervical dentinaria (SCD) y evaluar el efecto que la humedad y el cepillado tienen sobre ellos. Material y metodo: 140 discos de dentina (obtenidos de 3o molares humanos recien extraidos) se dividen en catorce grupos de 10 discos que se montan en un sistema de perfusion basado en la maquina de Pashley que mantiene una presion positiva sobre las discos. Cada disco se graba con acido ortofosforico al 35% y su permeabilidad se mide en una hora, este valor se considera el de referenc…
Effect of 2% Chlorhexidine Following Acid Etching on Microtensile Bond Strength of Resin Restorations: A Meta-Analysis.
Background and Objectives: The aim of this systematic review was to examine the effect of 2% chlorhexidine following acid etching on the microtensile bond strength of resin restorations for different follow-up times. Materials and Methods: A thorough search of PubMed, Scopus, and Embase databases were conducted. In vitro experimental studies or in vivo studies published up to December 2018 with an experimental group treated with a 2% chlorhexidine solution following acid etching and a control group were included, wherein the final restoration used a resin composite in both the groups. Results: Twenty-one articles were identified for qualitative analysis and 18 for meta-analysis. The differe…
Volumetric variation of peri-implant soft tissues in convergent collar implants and crowns using the biologically oriented preparation technique (BOPT)
Background To evaluate the changes in the peri-implant soft tissues of convergent collar implants with biologically oriented preparation technique (BOPT) crowns, 10 months after loading. Material and Methods A pilot study was carried out from January 2016 to October 2017 involving 14 patients with one or two implants in the posterior mandibular sector. A total of 32 convergent collar implants were placed using a non-submerged protocol. Three months later the provisional cemented crowns were fitted using the BOPT approach with the finish line 1-1.5 mm below the gingival margin, simulating coronal emergence of a natural tooth. The soft tissue changes were measured with an intraoral scanner at…
Influencia de la microabrasión en la fuerza de unión a esmalte de diferentes sistemas adhesivos
Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions
Background The scanner does not measure the dental surface continually. Instead, it generates a point cloud, and these points are then joined to form the scanned object. This approximation will depend on the number of points generated (resolution), which can lead to low accuracy (trueness and precision) when fewer points are obtained. The purpose of this study is to determine the resolution of four intraoral digital imaging systems and to demonstrate the relationship between accuracy and resolution of the intraoral scanner in impressions of a complete dental arch. Material and methods A master cast of the complete maxillary arch was prepared with different dental preparations. Using four di…