0000000000185424
AUTHOR
P. Schwamb
A compact apparatus for mass selective resonance ionization spectroscopy in a buffer gas cell
Abstract An ultra-sensitive laser spectroscopic method for the investigation of transuranium nuclides has been developed based on resonance ionization in an argon buffer gas cell. This method has been combined with ion-guide extraction and mass selective direct detection of the resonantly ionized atoms. Using argon as a buffer gas, recoils of fusion reactions can be thermalized even at low pressure. The differential pumping system consists of only one roots pump and two turbo molecular pumps. The set-up has been tested with 243 Am evaporated from a filament located inside the optical gas cell. Resonance ionization is performed using a two-step excitation with an excimer-dye-laser combinatio…
First Observation of Atomic Levels for the Element Fermium (Z=100)
The atomic level structure of the element fermium was investigated for the first time using a sample of $2.7\ifmmode\times\else\texttimes\fi{}{10}^{10}$ atoms of the isotope $^{255}\mathrm{F}\mathrm{m}$ with a half-life of 20.1 h. The atoms were evaporated from a filament and stored in the argon buffer gas of an optical cell. Atomic levels were sought by the method of resonance ionization spectroscopy using an excimer-dye-laser combination. Two atomic levels were found at wave numbers $(25\text{ }099.8\ifmmode\pm\else\textpm\fi{}0.2)$ and $(25\text{ }111.8\ifmmode\pm\else\textpm\fi{}0.2)\text{ }\text{ }{\mathrm{c}\mathrm{m}}^{\ensuremath{-}1}$. Partial transition rates to the $5{f}^{12}7{s}…
Radiation detected resonance ionization spectroscopy on208Tl and242fAm
An ultra-sensitive laser spectroscopic method has been developed for the hyperfine spectroscopy of short-lived isotopes far off stability produced by heavy ion induced nuclear reactions at very weak intensity (> 1/s). It is based on resonance ionization spectroscopy in a buffer gas cell with radiation detection of the ionization process (RADRIS). As a first on-line application of RADRIS optical spectroscopy at242fAm fission isomers is in progress at the low target production rate of 10/s. The resonance ionization has been performed in two steps utilizing an excimer dye laser combination with a repetition rate of 300 Hz. The first resonant step proceeds through terms which correspond to wave…
Resonance ionization spectroscopy of fermium (Z=100)
Laser spectroscopy has been applied for the first time to measure resonant transition frequencies of fermium (Zs 100). A number of 2.7=10 atoms was electrodeposited on a Ta filament and covered with a 1 mm Ti layer. Fm 10
Resonance ionization spectroscopy in a buffer gas cell with radioactive decay detection, demonstrated usingTl208
An ultrasensitive laser spectroscopic method has been developed to perform hyperfine spectroscopy of heavy-ion-induced reaction products. It is based on resonance ionization in a buffer gas cell combined with radioactive decay detection. The feasibility has been demonstrated using the \ensuremath{\beta}-active ${\mathrm{isotope}}^{208}$ Tl. A sensitivity of 1.3\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}3}$ of the two-step resonance-ionization process via the n=17 Rydberg level has been determined, utilizing a pulsed excimer-dye-laser combination. The previously unknown nuclear magnetic moment \ensuremath{\mu}${(}^{208}$Tl) = 0.292(13)${\mathrm{\ensuremath{\mu}}}_{\mathi…
Isotope Shift Measurements for Superdeformed Fission Isomeric States
Optical isotope shift measurements have been performed for the ${}^{240,242}{\mathrm{Am}}^{f}$ fission isomers with low target production rates of $10{\mathrm{s}}^{\ensuremath{-}1}$ employing resonance ionization spectroscopy in a buffer gas cell. Isotope shift ratios ${\mathrm{IS}}^{240f,241}/{\mathrm{IS}}^{243,241}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}39.2(8)$ and ${\mathrm{IS}}^{242f,241}/{\mathrm{IS}}^{243,241}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}41.4(8)$ have been measured at the 500.02 nm transition. A difference in the nuclear mean charge radii $\ensuremath{\delta}〈{r}^{2}{〉}_{\mathrm{opt}}^{242f,241}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}5.34(2…
Isotope shift and hyperfine structure measurements at the242f Am fission isomer
Istope shift and hyperfine structure measurements have been performed for the242fAm fission isomer with target production rates of only a few per second. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with radioactive decay detection of the ionization process (RADRIS). A relative isotope shift ratioX exp=IS242f,241/ IS243,241=41.7±0.9 has been measured for the 500.02 nm transition corresponding to a nuclear parameter Λ242f,241=5.4±0.3 fm2. The analysis of the quadrupole moment based on the deformed Fermi-model of the nuclear charge distribution including second order corrections results inQ 20=38.2 ±1.4( −0.8 +0.4 )model eb. The measurement of the hyperf…
First observation of a resonance ionization signal on242mAm fission isomers
The feasibility of a hyperfine spectroscopy on242mAm fission isomers has been demonstrated at the low target production rate of 10/s. The experimental method employed is based on resonance ionization spectroscopy in a buffer gas cell with detection of the ionization process by means of the fission decay of the isomers. The resonance ionization has been performed in two steps, utilizing an excimer dye laser combination with a repetition rate of 300 Hz. The first resonant step proceeds through theJ=7/2 term at 21440.35 cm−1, which has been excited with the tuncable dye laser beam of a wavelength of 466.28 nm, the second non-resonant step is achieved with the 351 nm radiation of the excimer la…