0000000000194767

AUTHOR

Francisco Javier Ampudia-blasco

0000-0003-0221-0901

Enfermedad cardiovascular en la diabetes mellitus

research product

Sequential Intensification of Metformin Treatment in Type 2 Diabetes With Liraglutide Followed by Randomized Addition of Basal Insulin Prompted by A1C Targets

OBJECTIVE We evaluated the addition of liraglutide to metformin in type 2 diabetes followed by intensification with basal insulin (detemir) if glycated hemoglobin (A1C) ≥7%. RESEARCH DESIGN AND METHODS In 988 participants from North America and Europe uncontrolled on metformin ± sulfonylurea, sulfonylurea was discontinued and liraglutide 1.8 mg/day added for 12 weeks (run-in). Subsequently, those with A1C ≥7% were randomized 1:1 to 26 weeks’ open-label addition of insulin detemir to metformin + liraglutide (n = 162) or continuation without insulin detemir (n = 161). Patients achieving A1C <7% continued unchanged treatment (observational arm). The primary end point was A1C change bet…

research product

Riesgo cardiovascular en sujetos con alta probabilidad de síndrome metabólico y resistencia a la insulina. Estudio DESIRE

Introduccion y objetivos El sindrome metabolico agrupa alteraciones estrechamente relacionadas. El objetivo principal de este estudio es conocer la frecuencia del sindrome metabolico y de la resistencia a la insulina, y su papel como indicadores de riesgo cardiovascular en poblacion adulta asignada a consultas de Atencion Primaria en Espana. Metodos Sujetos ≥ 45 anos con glucemia basal ≥ 90 mg/dl y perimetro de cintura ≥ 94 cm (hombres) u 80 cm (mujeres). Se utilizaron los criterios del ATP III modificados para identificar el sindrome metabolico y el indice HOMA > 3,29 para la resistencia a la insulina. El riesgo cardiovascular se estimo mediante los modelos Framingham y SCORE. Resultados S…

research product

Time-in-range for monitoring glucose control: Is it time for a change?

The HbA1c value has been the gold standard for evaluating glucose control for decades. However, it has limitations such as the lack of information on glycemic variability or the risk of hypoglycemia. The increasing use of continuous glucose monitoring has provided patients and healthcare professionals with a range of useful metrics for the management of diabetes. Among them, Time in Range (TIR) is a simple and intuitive metric that gives information regarding the quality of glucose control. It is defined as the time spent in an individual's target glucose range. TIR is strongly correlated with HbA1c, and it has been linked to the risk of developing microvascular and macrovascular complicati…

research product

Real‐world evidence of the effectiveness on glycaemic control of early simultaneous versus later sequential initiation of basal insulin and glucagon‐like peptide‐1 receptor agonists

Abstract Aim To assess the impact of the timing of initiating both basal insulin and glucagon‐like peptide‐1 receptor agonists (GLP‐1 RAs) on reaching glycaemic control targets over 6 and 12 months in people with type 2 diabetes (T2D) uncontrolled on oral antihyperglycaemic drugs with an HbA1c of 9% or higher. Methods This retrospective cohort study assessed the impact of the timing of initiating both basal insulin and GLP‐1 RA therapies on reaching glycaemic targets (HbA1c < 7% and <8%, and ≥1% and ≥2% HbA1c reduction) over 12 months in people with markedly uncontrolled T2D (HbA1c ≥ 9%) on oral antihyperglycaemic drugs identified on the Optum Humedica database (electronic medical records; …

research product

Old and new basal insulin formulations: understanding pharmacodynamics is still relevant in clinical practice.

Long-acting insulin analogues have been developed to mimic the physiology of basal insulin secretion more closely than human insulin formulations (Neutral Protamine Hagedorn, NPH). However, the clinical evidence in favour of analogues is still controversial. Although their major benefit as compared with NPH is a reduction in the hypoglycaemia risk, some cost/effectiveness analyses have not been favourable to analogues, largely because of their higher price. Nevertheless, these new formulations have conquered the insulin market. Human insulin represents currently no more than 20% of market share. Despite (in fact because of) the widespread use of insulin analogues it remains critical to anal…

research product

Biosimilars and Novel Insulins.

Background Insulin therapy is the mainstay of treatment for type 1 diabetes and may be necessary in type 2 diabetes. Current insulin analogues present a more physiological profile, are effective, and with less risk of hypoglycemia, but they are expensive. Biosimilar insulins should offer the advantages of insulin analogues at reduced costs. In addition, current rapid-acting insulin analogues are not fast enough to control excessive postprandial glucose excursions in many patients. Areas of uncertainty Biosimilar insulins demonstrated that are safe and effective, but interchangeability and automatic substitution remain an issue. Ultrafast-acting insulins should reduce postprandial hyperglyce…

research product

Rapid-Acting Insulin Analogues in Basal-Bolus Regimens in Type 1 Diabetes Mellitus

ABSTRACT Objective To compare rapid-acting insulin analogues with regular human insulin in terms of hemoglobin A1c, hypoglycemia, and insulin dose when used in a basal-bolus regimen in patients with type 1 diabetes mellitus. Methods MEDLINE and congress proceedings were searched for randomized controlled trials comparing pran- dial insulins in a basal-bolus regimen in adults or children/ adolescents with type 1 diabetes. Studies in pregnancy, ob- servational studies, studies that compared premixed insulin or continuous subcutaneous insulin infusion/insulin pumps, and studies where the basal insulin was also changed were excluded. Only studies reporting baseline-endpoint change in insulin do…

research product

Plasma Insulin Levels and Hypoglycemia Affect Subcutaneous Interstitial Glucose Concentration

[EN] Background: Continuous glucose monitoring (CGM) accuracy during hypoglycemia is suboptimal. This might be partly explained by insulin or hypoglycemia-induced changes in the plasma interstitial subcutaneous (SC) fluid glucose gradient. The aim of the present study was to assess the role of plasma insulin (PI) and hypoglycemia itself in the plasma and interstitial SC fluid glucose concentration in patients with type 1 diabetes mellitus. Methods: Eleven subjects with type 1 diabetes (age 36.59.1 years, HbA(1c) 7.90.4% [62.8 +/- 2.02mmol/mol]; mean +/- standard deviation) were evaluated under hyperinsulinemic euglycemia and hypoglycemia. Each subject underwent two randomized crossover clam…

research product

Characteristics of patients with type 2 diabetes mellitus newly treated with GLP-1 receptor agonists (CHADIG Study): a cross-sectional multicentre study in Spain

Ajuda rebuda: GlaxoSmithKline Several glucagon-like peptide-1 (GLP-1) receptor agonists (GLP-1Ra) have been made recently available in Spain for type 2 diabetes mellitus (DM2) treatment. There are no published data on the clinical and sociodemographic profile of patients initiating treatment with GLP-1Ra in Spain. Our objective was to understand these patients' characteristics in a real-world clinical practice setting. Design. Cross-sectional observational study. Setting. Spanish specialist outpatient clinics.Participants 403 adults with DM2 initiating GLP-1Ra treatment were included. Primary and secondary outcome measures Sociodemographic and DM2-related clinical data, including treatment …

research product

40(th) EASD Annual Meeting of the European Association for the Study of Diabetes : Munich, Germany, 5-9 September 2004

research product

A cross-sectional survey among patients and prescribers on insulin dosing irregularities and impact of mild (self-treated) hypoglycemia episodes in Spanish patients with type 2 diabetes as compared to other European patients.

In Spain, data suggest that 13.8% of adults have diabetes. Two important aspects in diabetes management are mild hypoglycemic episodes and poor treatment adherence. This study assesses the impact of missed insulin doses and prevalence of mistimed and reduced insulin doses and mild hypoglycemia in patients with type 2 diabetes treated with basal insulin analogues in Spain, and compares the data collected to pooled data from 8 other European countries (OECs).GAPP2 was an international, online, cross-sectional study of diabetic patients aged ≥40 years treated with long-acting insulin analogues and their healthcare professionals. Patients and healthcare professionals were recruited from online …

research product

Clinical Approach to Flash Glucose Monitoring: An Expert Recommendation

The flash glucose monitoring (FGM) system FreeStyle Libre® is a device that measures interstitial glucose in a very simple way and indicates direction and speed of glucose change. This allows persons with diabetes to prevent hypoglycemic and hyperglycemic events. Scientific evidence indicates that the system can improve glycemic control and quality of life. To obtain the maximum benefit, it is necessary to properly handle glucose values and trends. Due to the generalization of the system use, the purpose of the document is to provide recommendations for the optimal use of the device, not only in the management of glucose values and trends but also in the prevention of hypoglycemia, actuati…

research product

Real-time estimation of plasma insulin concentration from continuous glucose monitor measurements

Continuous glucose monitors can measure interstitial glucose concentration in real time for closed-loop glucose control systems, known as artificial pancreas. These control systems use an insulin feedback to maintain plasma glucose concentration within a narrow and safe range, and thus to avoid health complications. As it is not possible to measure plasma insulin concentration in real time, insulin models have been used in literature to estimate them. Nevertheless, the significant interand intra-patient variability of insulin absorption jeopardizes the accuracy of these estimations. In order to reduce these limitations, our objective is to perform a real-time estimation of plasma insulin co…

research product

An Analysis of “No Effect of Insulin Pen with Memory Function on Glycemic Control in a Patient Cohort with Poorly Controlled Type 1 Diabetes: A Randomized Open-Label Study”

Missing meal bolus and nonadherence is an important barrier to achieving glycemic goals in type 1 diabetes (T1DM). In this issue of Journal of Diabetes Science and Technology, Danne and coauthors reported the results of a 24-week randomized-controlled study designed to evaluate if using an insulin pen with memory function, the HumaPen® Memoir™, might improve injection compliance and, therefore, overall glycemic control in T1DM. Patients treated with the pen device with memory function improved, albeit nonsignificantly, their mean HbA1c by 0.43%. Among the reasons to justify why this study was not positive, the most important is the high proportion of adult patients included in the study (87…

research product

Futuro de las glitazonas

research product