0000000000198935

AUTHOR

O. Kiselev

Coulomb dissociation of 27P

International audience; In this work the astrophysical 26Si(p,γ)27P reaction is studied using the Coulomb dissociation technique. We performed a 27P Coulomb Dissociation experiment at GSI, Darmstadt (28 May-5 June 2007) using the ALADIN-LAND setup which allows complete-kinematic studies. A secondary 27P beam at 498 AMeV impinging a 515mg/cm2 Pb target was used. The relative energy of the outgoing system (26Si+p) is measured obtaining the resonant states of the 27P. Preliminary results show four resonant states measured at 0.36±0.07, 0.88±0.09, 1.5±0.2, 2.3±0.3 MeV and evidence of a higher state at around 3.1 MeV. The preliminary total cross section obtained for relative energies between 0 a…

research product

Comparison of electromagnetic and nuclear dissociation of Ne-17

8 pags., 10 figs., 3 tabs.

research product

Development of an array of calorimetric low-temperature detectors for heavy ion physics

Abstract Calorimetric low-temperature detectors have been investigated for several applications in heavy ion physics within the last 15 years. The detectors used consist of sapphire absorbers of 2×3×0.33 mm 3 and superconducting aluminum transition edge sensors operated at T ≈1.5 K. To fully exploit the potential of such detectors for heavy ion physics, a detector array is developed. For this purpose, a specially adapted 4 He bath cryostat with a base temperature of 1.2 K, which allows an active detector area of 30×80 mm 2 , was constructed. As different detectors have different transition temperatures, each detector pixel has to be adjusted to its specific working point and temperature sta…

research product

First application of calorimetric low-temperature detectors in accelerator mass spectrometry

Abstract For the first time, calorimetric low-temperature detectors were applied in accelerator mass spectrometry, a well-known method for determination of very small isotope ratios with high sensitivity. The aim of the experiment was to determine with high accuracy the isotope ratio of 236U/238U for several samples of natural uranium, 236U being known as a sensitive monitor for neutron flux. Measurements were performed at the VERA tandem accelerator at Vienna, Austria. The detectors consist of sapphire absorbers and superconducting transition edge thermometers operated at T≈ 1.5 K. The relative energy resolution obtained for 17.39 MeV 238U is ΔE/E=4–9×10−3, depending on the experimental co…

research product

Noise analysis for calorimetric low-temperature detectors for heavy ions

The energy resolution of calorimetric low-temperature detectors for heavy ions has been analyzed. It is shown that the contribution of base line noise is small. The energy resolution is determined by intrinsic fluctuations of the detector signal. An incomplete energy thermalization during the stopping process of the heavy ion, the dependence of signal shape on impact position and fluctuations of the Al-TES thermometer response are considered as main sources of detector line broadening. Test measurements with 5 MeV α-particles are presented.

research product

Measurement of the Dipole Polarizability of the Unstable Neutron-Rich NucleusNi68

The E1 strength distribution in Ni68 has been investigated using Coulomb excitation in inverse kinematics at the RB3-LAND setup and by measuring the invariant mass in the one- and two-neutron decay channels. The giant dipole resonance and a low-lying peak (pygmy dipole resonance) have been observed at 17.1(2) and 9.55(17) MeV, respectively. The measured dipole polarizability is compared to relativistic random phase approximation calculations yielding a neutron-skin thickness of 0.17(2) fm. A method and analysis applicable to neutron-rich nuclei has been developed, allowing for a precise determination of neutron skins in nuclei as a function of neutron excess.

research product

Resonance State inH7

The existence of the $^{7}\mathrm{H}$ nuclear system was investigated via a one-proton transfer reaction with a $^{8}\mathrm{He}$ beam at $15.4\mathrm{A}\text{ }\text{ }\mathrm{MeV}$ and a $^{12}\mathrm{C}$ gas target. The experimental setup was based on the active-target MAYA which allowed a complete reconstruction of the reaction kinematics. The existence of the $^{7}\mathrm{H}$ was confirmed with the identification of seven events where the system was formed with a resonance energy of ${0.57}_{\ensuremath{-}0.21}^{+0.42}\text{ }\text{ }\mathrm{MeV}$ above the $^{3}\mathrm{H}+4n$ threshold and a resonance width of ${0.09}_{\ensuremath{-}0.06}^{+0.94}\text{ }\text{ }\mathrm{MeV}$. This stu…

research product

Precise determination of the 1s Lamb Shift in hydrogen-like heavy ions at the ESR storage ring using microcalorimeters

The precise determination of the energy of the Lyman α1 and α2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. To improve the precision of such experiments, the new detector concept of microcalorimeters, which detect the temperature change of an absorber after an incoming particle or photon has deposited its energy as heat, is now exploited. The microcalorimeters for x-rays used in these experiments consist of arrays of silicon thermometers and x-ray absorbers made of high-Z material. With such detectors, a relative energy resolution of about 1 per mille is obtained in the energy regime of 50–100 keV. Two successful measu…

research product

Study of the $^{15}$O(2p, γ )$^{17}$Ne cross section by Coulomb dissociation of $^{17}$Ne for the rp process of nucleosynthesis

Acta physica Polonica / B 45(2), 229 - 234 (2014). doi:10.5506/APhysPolB.45.229

research product

Target dependence in the study of collective modes in stable and exotic Ni nuclei

The appearance of the pygmy-dipole-resonance is a recently observed phenomenon that can be related to neutron-matter properties. Its study can be a tool to determine the nuclear symmetry-energy parameters and thus can contribute constraining neutron star models. We present the ( γ,n ) cross sections for different Ni isotopes obtained from a measurement in inverse kinematics at about 500 MeV/u in the LAND reaction setup at GSI. The question of the disentanglement of the Coulomb and nuclear contributions is addressed.

research product

High-precision X-ray spectroscopy of highly-charged ions at the experimental storage ring using silicon microcalorimeters

Abstract X-ray spectroscopy on highly charged heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. One limitation of the current accuracy of such experiments is the energy resolution of available X-ray detectors for energies up to 100 keV. To improve this accuracy, a novel detector concept, namely the concept of microcalorimeters, is exploited for this kind of measurements. The microcalorimeters used in the present experiments consist of silicon thermometers, ensuring a high dynamic range, and of absorbers made of high-Z material to provide high X-ray absorption efficiency. Recently, besides an earlier used detector, a new compact detector design, h…

research product

Experimental study of the 15O(2p, γ)17Ne cross section by Coulomb Dissociation for the rp process

6th Nuclear Physics in Astrophysics Conference (NPA), Lisbon, Portugal, 19 May 2013 - 24 May 2013; Journal of physics / Conference Series 665, 012046 (2016). doi:10.1088/1742-6596/665/1/012046

research product

Coulomb dissociation of 27P: A reaction of astrophysical interest

The ground-state decay of 26Al(0+) (T 1/2=1.05× 106) has a shorter life-time than the Universe. The presence of this element in the Galaxy was measured via g-ray spectroscopy, showing that the nucleosynthesis of this element is an ongoing process in stars. The proton-capture reaction 26Si(p,γ) 27P competes with the production of 26Al(0+) by β-decay. Coulomb dissociation of 27P has been suggested as an indirect method to measure radiative-proton capture when the direct reaction is not feasible. Such an experiment was performed at GSI with a secondary 27P beam produced by fragmenting a 36Ar primary beam at 500 A MeV. Two main observables are preliminarily presented in this work: the reaction …

research product

Production and Characterization of the $^{7}$H Resonance

Détecteur MAYA; International audience; The 7H resonance was produced via one-proton transfer reaction between a 8He beam at 15.4A MeV and a 12C gas target. The experimental setup was based on the active-target MAYA which allowed a complete reconstruction of the reaction kinematics. The characterization of the identified 7H events resulted in a resonance energy of 600 keV above the 3H+4n threshold and a resonance width of 100 keV. This study represents the first unambiguous proof of the existence of the 7H state.

research product

Precise determination of the 1s Lamb shift in hydrogen-like lead and gold using microcalorimeters

Quantum electrodynamics in very strong Coulomb fields is one scope which has not yet been tested experimentally with suffcient accuracy to really determine whether the perturbative approach is valid. One sensitive test is the determination of the 1s Lamb Shift in highly-charged very heavy ions. The 1s Lamb Shift of hydrogen-like lead (Pb81+) and gold (Au78+) has been determined using the novel detector concept of silicon microcalorimeters for the detection of hard X-rays. The results of (260 +- 22) eV for lead and (208 +- 13) eV for gold are within error bars in good agreement with theoretical predictions. For hydrogen-like lead, this represents the most accurate determination of the 1s Lam…

research product

Coulomb dissociation of P 27 at 500 MeV/u

J. Marganiec et al. ; 15 págs.; 14 figs.; 6 tabs.

research product

Proton-proton correlations observed in two-proton decay of $^{19}$Mg and $^{16}$Ne

Proton-proton correlations were observed for the two-proton decays of the ground states of $^{19}$Mg and $^{16}$Ne. The trajectories of the respective decay products, $^{17}$Ne+p+p and $^{14}$O+p+p, were measured by using a tracking technique with microstrip detectors. These data were used to reconstruct the angular correlations of fragments projected on planes transverse to the precursor momenta. The measured three-particle correlations reflect a genuine three-body decay mechanism and allowed us to obtain spectroscopic information on the precursors with valence protons in the $sd$ shell.

research product

High-precision x-ray spectroscopy of highly charged ions with microcalorimeters

The precise determination of the energy of the Lyman α1 and α2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. To improve the experimental precision, the new detector concept of microcalorimeters is now exploited for such measurements. Such detectors consist of compensated-doped silicon thermistors and Pb or Sn absorbers to obtain high quantum efficiency in the energy range of 40–70 keV, where the Doppler-shifted Lyman lines are located. For the first time, a microcalorimeter was applied in an experiment to precisely determine the transition energy of the Lyman lines of lead ions at the experimental storage ring at GSI. T…

research product

Mass measurements of As, Se, and Br nuclei, and their implication on the proton-neutron interaction strength toward the N=Z line

Mass measurements of the $^{69}$As, $^{70,71}$Se and $^{71}$Br isotopes, produced via fragmentation of a $^{124}$Xe primary beam at the FRS at GSI, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with an unprecedented mass resolving power of almost 1,000,000. For the $^{69}$As isotope, this is the first direct mass measurement. A mass uncertainty of 22 keV was achieved with only 10 events. For the $^{70}$Se isotope, a mass uncertainty of 2.6 keV was obtained, corresponding to a relative accuracy of $\delta$m/m = 4.0$\times 10^{-8}$, with less than 500 events. The masses of the $^{71}$Se and $^{71}$Br isotopes were measured…

research product