0000000000206018

AUTHOR

M. Müller

showing 8 related works from this author

Multisensory vestibular cortex activated by otolith stimulation (fMRI)

2007

medicine.anatomical_structureNeurologyPhysiology (medical)medicineStimulationAnatomyNeurology (clinical)BiologyVestibular cortexNeuroscienceSensory SystemsOtolithClinical Neurophysiology
researchProduct

Cytoplasmic microvesicles in chromophobe cell renal carcinoma demonstrated by freeze fracture

1987

In the chromophobe cell type of renal carcinoma, cytoplasmic microvesicles (frequently with "inner vesicles") demonstrable by transmission electron microscopy are one of the most important diagnostic features. The present paper reports on these microvesicles in freeze fracture replicas. Their diameter is mainly between 140 and 300 micron, but smaller and very much larger vesicles may also occur. The vesicle membrane is devoid of, or contains only scanty intramembranous particles. Cytoplasmic invaginations, probably the precursors of "inner vesicles" can also be detected. Connections with the agranular endoplasmic reticulum, mitochondria or other cell components could not be documented. Larg…

CytoplasmPathologymedicine.medical_specialtyKidneyVesicleCellChromophobe cellVacuoleBiologyMitochondrionKidney NeoplasmsMicrovesiclesmedicine.anatomical_structureCytoplasmmedicineFreeze FracturingHumansCarcinoma Renal CellVirchows Archiv B Cell Pathology Including Molecular Pathology
researchProduct

Technical design of the phase I Mu3e experiment

2021

Nuclear instruments & methods in physics research / A 1014, 165679 (2021). doi:10.1016/j.nima.2021.165679

Nuclear and High Energy PhysicsParticle physicsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsflavor: violation [lepton]FOS: Physical sciencesElectron7. Clean energy01 natural sciences530muon: decayTechnical designMuon decaysHigh Energy Physics - Experimentdesign [detector]High Energy Physics - Experiment (hep-ex)decay [muon]Scintillating tilesPositronsemiconductor detector: pixelScintillating fibres0103 physical sciencesscintillation counter: fibreddc:530tracking detector010306 general physicsInstrumentationEngineering & allied operationsactivity reportdetector: designPhysicspixel [semiconductor detector]MuonPixel010308 nuclear & particles physicsDetectorMonolithic pixel detectorlepton: flavor: violationInstrumentation and Detectors (physics.ins-det)fibre [scintillation counter]sensitivityLepton flavour violationBeamlineHigh Energy Physics::Experimentddc:620performanceLepton
researchProduct

Akute Gefäßverschlüsse — interdisziplinäres Therapiespektrum

1995

Unter dem speziellen Gesichtspunkt der Verbesserung der Behandlungsergebnisse des akuten Ischamie-Syndroms der unteren Extremitaten erfolgte eine retrospektive Analyse von 344 Patienten. Eine arterielle Embolie lag in 46,4%, eine akute Thrombose in 32,7%, den akuten Verschlussen zugrunde. In 20,9% war eine eindeutige Zuordnung der Verschlusursache nicht moglich. Das Zeitintervall zwischen Symptom und Beginn der Therapie betrug bei den Embolien in 29% und bei den Thrombosen in 41% mehr als zwolf Stunden. In 67% wurde eine transfemorale indirekte Thrombembolektomie durchgefuhrt. Durch den Einsatz neuerer risikoarmer Behandlungsmethoden (Aspirationsembolektomie, Lyse und PTA etc.) last sich da…

researchProduct

The Mu3e Data Acquisition

2020

The Mu3e experiment aims to find or exclude the lepton flavour violating decay $\mu^+\to e^+e^-e^+$ with a sensitivity of one in 10$^{16}$ muon decays. The first phase of the experiment is currently under construction at the Paul Scherrer Institute (PSI, Switzerland), where beams with up to 10$^8$ muons per second are available. The detector will consist of an ultra-thin pixel tracker made from High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), complemented by scintillating tiles and fibres for precise timing measurements. The experiment produces about 100 Gbit/s of zero-suppressed data which are transported to a filter farm using a network of FPGAs and fast optical links. On the filte…

Nuclear and High Energy PhysicsParticle physicsPhysics - Instrumentation and DetectorsMesonPhysics::Instrumentation and Detectorsdata acquisitionfibre: opticalFOS: Physical scienceshigh energy physics instrumentationprinted circuits7. Clean energycomputer: networkOptical fiber communicationData acquisitionsemiconductor detector: pixelOptical switchesmultiprocessor: graphicshardwareSensitivity (control systems)muon+: decay[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Electrical and Electronic EngineeringGeneralLiterature_REFERENCE(e.g.dictionariesencyclopediasglossaries)scintillation counterFPGAClocksPhysicsData acquisition (DAQ)MuonPixelMesonsDetectorlepton: flavor: violationField programmable gate arraysDetectorsInstrumentation and Detectors (physics.ins-det)sensitivityNuclear Energy and EngineeringFilter (video)field programmable gate arrays (FPGAs)Data acquisition (DAQ); field programmable gate arrays (FPGAs); high energy physics instrumentation; printed circuitselectronics: readoutHigh Energy Physics::ExperimentLeptonelectronics: design
researchProduct

Isotope dilution inductively coupled plasma quadrupole mass spectrometry in connection with a chromatographic separation for ultra trace determinatio…

2000

An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt,…

Radioisotope Dilution TechniqueAnalytical chemistrychemistry.chemical_elementDustIsotope dilutionChromatography Ion ExchangeMass spectrometrySensitivity and SpecificityBiochemistryMass SpectrometryRutheniumSoilchemistry.chemical_compoundchemistryMetals HeavyAqua regiaEnvironmental PollutantsIridiumInductively coupled plasmaPlatinumPlatinumVehicle EmissionsPalladiumFresenius' Journal of Analytical Chemistry
researchProduct

Eosinophil granule proteins in serum and urine of patients with helminth infections and atopic dermatitis.

2001

Eosinophil cationic protein (ECP) and eosinophil-derived neurotoxin (EPX) are cytotoxic molecules involved in helminth infections and allergic reactions. Hitherto most clinical chemical studies have been concerned with the analysis of serum ECP in allergic diseases. The aim of this study was to examine whether serum as well as urine levels of these proteins are useful clinical chemical parameters in helminthiases and allergic diseases such as atopic dermatitis. Comparing these diseases under the same methodological conditions, levels of ECP and EPX were generally higher in helminthiases than in atopic dermatitis and non-helminth, non-allergic diseases. The highest levels of both proteins oc…

AdultMaleAllergyAdolescentHelminthiasisHelminthiasisEosinophil-derived neurotoxinSchistosomiasisEosinophil-Derived NeurotoxinBiologyDermatitis AtopicAtopyRibonucleasesPredictive Value of Testsparasitic diseasesmedicineEosinophiliaHumansEosinophil cationic proteinPublic Health Environmental and Occupational HealthProteinsAtopic dermatitisBlood ProteinsEosinophil Granule ProteinsMiddle Agedmedicine.diseaseInfectious DiseasesCase-Control StudiesImmunologyParasitologyFemalemedicine.symptomTropical medicineinternational health : TMIH
researchProduct

Performance of the large scale HV-CMOS pixel sensor MuPix8

2019

The Mu3e experiment is searching for the charged lepton flavour violating decay $ ��^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers of $50\, ��\text{m}$ thin High Voltage Monolithic Active Pixel Sensors (HV-MAPS) placed in a $1\,\text{T}$ magnetic field. The measurement of the trajectories of the decay particles allows for a precise vertex and momentum reconstruction. Additional layers of fast scintillating fibre and tile detec…

PhysicsMuonPhysics - Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)01 natural sciencesParticle detector030218 nuclear medicine & medical imagingSemiconductor detectorMomentum03 medical and health sciencesParticle decay0302 clinical medicineOpticsCMOS0103 physical sciencesHigh Energy Physics::ExperimentbusinessInstrumentationMathematical PhysicsLepton
researchProduct