0000000000207774

AUTHOR

José Martínez Calatayud

showing 4 related works from this author

Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals

2007

Abstract A review is presented on the state of the art of the chemiluminescence analysis of pharmaceuticals by the two most relevant automated controlled-flow methodologies—flow-injection analysis (FIA) and sequential-injection analysis (SIA). The current chemiluminometric applications of FIA and SIA in pharmaceutical analysis are discussed with special emphasis on the analytical figures of merit and sample matrix characteristics. The review involving 211 references and covering papers published between 2001 and 2006 is divided into several sections according to the fundamental types of chemiluminescence systems employed.

Sequential injection analysisbusiness.industryChemistryClinical BiochemistryAnalytical chemistryPharmaceutical ScienceAnalytical Chemistrylaw.inventionPharmaceutical PreparationslawFlow Injection AnalysisLuminescent MeasurementsDrug DiscoveryProcess engineeringbusinessOxidation-ReductionSpectroscopyChemiluminescenceJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Sequential injection analysis (SIA)-chemiluminescence determination of indomethacin using tris[(2,2'-bipyridyl)]ruthenium(III) as reagent and its app…

2006

Abstract Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin ( I ) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy) 3 3+ ) in the presence of acetate. The Ru(bipy) 3 3+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy) 3 2+ ) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy) 3 …

IndomethacinAnalytical chemistrychemistry.chemical_elementBiochemistryDosage formAnalytical Chemistrylaw.inventionlawSpectrophotometrymedicineOrganometallic CompoundsEnvironmental ChemistrySpectroscopyChemiluminescenceDetection limitDosage FormsAqueous solutionmedicine.diagnostic_testMolecular StructureReproducibility of ResultsRutheniumStandard curvechemistryReagentCalibrationFlow Injection AnalysisLuminescent MeasurementsSolventsNuclear chemistryAnalytica chimica acta
researchProduct

FIA-Fluorimetric assembly for the determination of noradrenaline hydrochloride by a solid-phase reactor with immobilized hexacyanoferrate(III)

1997

An FIA assembly provided with immobilized hexacyanoferrate(III) is proposed for the fluorimetric determination of noradrenaline hydrochloride. The oxidative reagent is immobilized by means of a strong anion-exchange resin. The FIA manifold is very simple and the calibration graph is linear over the range 0.5–75mgl−1 noradrenaline hydrochloride with an r.s.d of 0.88% (17 replicates) and a sample throughput of 84h−1. Foreign compounds such as NaCl, sucrose, lactose and sodium sulfate caused no significant errors. The procedure is applied to the determination of noradrenaline in a medicinal formulation.

chemistry.chemical_compoundChromatographychemistryHydrochlorideCalibration curveReagentSodium sulfateFluorescence spectrometryQuantitative analysis (chemistry)Dosage formFluorescence spectroscopyAnalytical ChemistryMikrochimica Acta
researchProduct

Determination of Phenylephrine Hydrochloride by Flow Injection Analysis with Chemiluminescence Detection

2001

Abstract A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80°C. The calibration graph is linear over the range 0.03–8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ppm) of 1.1% and sample throughput of 134/h. The influence of 38 different foreign compounds was tested, and the method was applied to the determination of phenylephrine hydrochloride in 8 different pharmaceutical formulations.

PharmacologyFlow injection analysisChromatographyChemistryCalibration curveAnalytical chemistryPhenylephrine HydrochlorideDosage formAnalytical Chemistrylaw.inventionPotassium permanganatechemistry.chemical_compoundlawmedicineEnvironmental ChemistryAgronomy and Crop SciencePhenylephrineQuantitative analysis (chemistry)Food Sciencemedicine.drugChemiluminescenceJournal of AOAC INTERNATIONAL
researchProduct