Development of a 3D CZT Spectrometer System with Digital Readout for Hard X/Gamma-Ray Astronomy

2019

We report on the development and of a complete X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimensions (3D) and a digital electronics acquisition chain. The prototype is made by packing four linear modules, each composed of one 3D CZT sensors. Each sensors is realized using a single spectroscopic graded CZT crystal of about 20×20×5 mm3. An electrode structure consisting of 12 collecting anodes with a pitch of 1.6 mm and 3 drift strips between each pair of anodes for 48 strips (0.15 mm wide) on the anodic side was adopted. The cathode is made of 10 strips with a pitch of 2 mm and orthogonal to anode side strips. Since the reading of the …

Materials scienceSTRIPSCZT detectorsensorscomputer.software_genre01 natural scienceslaw.invention010309 opticsOpticslaw0103 physical sciencesDigital Readout010303 astronomy & astrophysicsImage resolutionDigital electronicsX-ray and gamma ray detectorsSpectrometerbusiness.industryFirmwareSettore FIS/01 - Fisica SperimentaleDetectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CathodeAnode3D CZTbusinesscomputer2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System

2012

In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…

digital pulse processingmammographyAnalytical chemistrylcsh:Chemical technologyBiochemistryArticleAnalytical ChemistryCdTe detectorsCdTe detectorOpticsmedicineCadmium CompoundsMammographylcsh:TP1-1185Computer SimulationElectrical and Electronic EngineeringInstrumentationPhysicsDosimetermedicine.diagnostic_testbusiness.industryAttenuationSpectrum AnalysisX-RaysDetectorSettore FIS/01 - Fisica Sperimentalehigh photon counting rateCdTe detectors Digital Pulse Processing MammographySignal Processing Computer-AssistedAtomic and Molecular Physics and OpticsPhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Full width at half maximumX-ray spectroscopy; high photon counting rate; CdTe detectors; digital pulse processing; mammographyIonization chamberX-ray spectroscopyTelluriumbusinessHalf-value layerSensors; Volume 12; Issue 6; Pages: 8390-8404
researchProduct

Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications

2009

Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact and reliable detection systems. In this paper, we review the current status of research in the development of CdTe and CdZnTe detectors by a comprehensive survey on the material properties, the device characteristics, the different techniques for improving the overall detector…

compound semiconductorsSiliconcompound semiconductorchemistry.chemical_elementNanotechnologyGermaniumReviewlcsh:Chemical technologyBiochemistryAnalytical Chemistrychemistry.chemical_compoundX-ray and gamma ray spectroscopylcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationcompound semiconductors; CdTe and CdZnTe detectors; X-ray and gamma ray spectroscopyPhysicsSpectrometerbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleWide-bandgap semiconductorCdTe and CdZnTe detectorCdTe and CdZnTe detectorsSemiconductor radiation detectorsAtomic and Molecular Physics and OpticsCadmium telluride photovoltaicsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc telluridechemistryOptoelectronicsbusiness
researchProduct

CdTe Detectors

2014

Cadmium telluride (CdTe) compound semiconductors for x-ray detectors have experienced a rather rapid development in the last few years, due to their appealing performance. In this chapter we review the physical properties of semiconductor detectors for x-ray and γ ray spectroscopy. In particular, we focus on compound semiconductor detectors. We also review the principles of operation of both the semiconductor detectors and the electronic chains, with special emphasis on the digital techniques. CdTe detectors’ characteristics and performance enhancements are discussed in depth. Finally, we present some original results on CdTe detectors for medical applications.

Materials sciencePhysics::Instrumentation and DetectorsCondensed Matter::Otherbusiness.industryPhysics::Medical PhysicsDetectorSettore FIS/01 - Fisica SperimentaleCdte detectorCadmium telluride photovoltaicsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Semiconductor detectorCondensed Matter::Materials ScienceOptoelectronicsCompound semiconductorHigh Energy Physics::ExperimentbusinessSpectroscopyCdTe semiconductor detectors X-ray spectroscopy digital pulse processing medical applications
researchProduct

Portable CdTe detection system for mammographic X-ray spectroscopy

2006

This paper describes a portable apparatus to be utilized in mammographic X-ray spectroscopy under clinical conditions. The system, based on a CdTe solid-state detector, is able to directly measure mammographic X-ray tube spectra. Good system response to monoenergetic photons was measured using X-ray and γ-ray calibration sources (109Cd and 241Am). The measured molybdenum X-ray spectra, in agreement with simulated spectra, show the good spectral capability of the system also at high photon fluence rates, as typical of clinical mammography. Low tailing, no secondary X-ray escape and low pile-up distortions in the measured spectra indicate that this portable system is suitable for mammographic…

SPECTRA
researchProduct

Development of a 3D CZT detector prototype for Laue Lens telescope

2010

We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (similar to 19x8 mm(2) area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode side is segmented in 64 strips, that divide the crystal in 8 independent sensor (pixel), each composed by one collecting strip and 7 (one in common) adjacent drift strips. The drift strips are biased by a voltage divider, whereas the anode strips are held at ground. Furthermore, the cathode is divided in 4 horizontal strips for the reconstruction of the third interaction position coord…

CDTE DETECTORSPhysicsPhysics::Instrumentation and Detectorsbusiness.industryDetectorVoltage dividerGamma ray spectroscopySTRIPSCZT detectorCZT detectors 3D detectors Laue lensCathodeParticle detectorlaw.inventionAnodeLens (optics)TelescopeOpticsHard X- and soft gamma-ray astronomy3D imagingDrift striplawCDZNTEbusiness
researchProduct

Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.

2020

In the last two decades, great efforts have been made in the development of 3D cadmium–zinc–telluride (CZT) detectors operating at room temperature for gamma-ray spectroscopic imaging. This work presents the spectroscopic performance of new high-resolution CZT drift strip detectors, recently developed at IMEM-CNR of Parma (Italy) in collaboration with due2lab (Italy). The detectors (19.4 mm × 19.4 mm × 6 mm) are organized into collecting anode strips (pitch of 1.6 mm) and drift strips (pitch of 0.4 mm) which are negatively biased to optimize electron charge collection. The cathode is divided into strips orthogonal to the anode strips with a pitch of 2 mm. Dedicated pulse processing analysis…

Nuclear and High Energy PhysicsMaterials sciencePhysics::Instrumentation and Detectors030303 biophysics3D CdZnTe detectorsSTRIPS01 natural sciencesElectric chargelaw.invention03 medical and health scienceschemistry.chemical_compounddrift strip detectorslaw0103 physical sciencesInstrumentation0303 health sciencesRadiation010308 nuclear & particles physicsbusiness.industryDetectorElectrostatic inductionSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CathodeCadmium zinc tellurideAnodeFull width at half maximumX-ray and gamma-ray detectorschemistryX-ray and gamma-ray detectors; 3D CdZnTe detectors; drift strip detectors; spectroscopic X-ray and gamma-ray imagingOptoelectronicsbusinessspectroscopic X-ray and gamma-ray imagingJournal of synchrotron radiation