0000000000214716
AUTHOR
Claus-peter H. Ernst
Business Intelligence in the Database Marketing – A Case Study of a German Insurance Company
Friendly, Humorous, Incompetent? On the Influence of Emoticons on Interpersonal Perception in the Workplace
Reduction of Polymerization Shrinkage Stress and Marginal Microleakage Using Soft-Start Polymerization
Purpose: This study evaluated the influence of a soft-start light-curing exposure on polymerization shrinkage stress and marginal integrity of adhesive restorations. Materials and Methods: Six resin-based composites (Pertac II, Tetric Ceram, Definite, Surefil, Solitaire, and Visio-Molar) were adhesively bonded to a cylindrical cavity (n = 9 per material/light) in a photoelastic material. Visible light-curing was applied using either the standard polymerization mode (800 mW/cm2 exposure duration 40 s) of the curing light (Elipar TriLight, 3M ESPE) or the exponential mode from the same device (ramp-curing: 150 mW/cm2 to 800 mW/cm2 within the first 15 s of a total curing time of 40 s). Polymer…
Individual Rank and Response: Survey-Based Evidence on the Effects of Rank-Based Performance Feedback
Determination of polymerization shrinkage stress by means of a photoelastic investigation
This study examined the polymerization stress of different established composite resins (Tetric Ceram, Vivadent; EsthetX, Surefil, Dentsply/DeTrey; Clearfil AP-X, Clearfil Photo Posterior, Kuraray; Prodigy Condensable, sds Kerr; Filtek P 60, 3M ESPE; Solitaire 2, Heraeus-Kulzer) by means of a photo-elastic investigation and investigated six new, experimental composite resins, which have been claimed to exhibit less polymerization shrinkage (InTen-S, Vivadent; K 112, K 051, Dentsply/DeTrey; Compox, Pluto, Hermes 3M ESPE).Cylindrical cavities (phi 5 mm) in Araldit B epoxide resin plates (40 x 40 x 3 mm3) were pretreated with the Rocatec system to ensure bonding of the composite resin. Ten com…
Minimal exposure time of different LED-curing devices
Abstract Objectives The purpose of the study was to investigate the shortest possible exposure time of different LED-curing devices for five different resin composites in a clinically relevant in vitro-model, where a 7 mm distance from the light guide tip to the bottom side of the cavity was compiled. Methods Resin composite samples (Tetric EvoCeram A3, Filtek Supreme XT A3B, Premise A3, CeramX Mono M5, QuiXfil) were filled in three increments of 2 mm thickness each in stainless steel moulds (O = 5 mm, h = 6 mm, n = 9). The samples were incrementally exposed to different blue LED-curing devices (Bluephase, Bluephase C8, Bluephase 16i/Ivoclar Vivadent, L.E.Demetron II/sds Kerr, Elipar Free…
Gender Stereotyping’s Influence on the Perceived Competence of Siri and Co.
Marginal integrity of class V restorations: SEM versus dye penetration.
To perform an in vitro investigation on the marginal integrity of different adhesives (Optibond FL, Scotchbond 1XT, Clearfil SE Bond, Adper Prompt L-Pop, S(3) Bond, iBond exp., Adper Prompt L-Pop) in combination with Tetric Ceram as well as an experimental silorane-restorative (Hermes, Hermes Bond; 3M ESPE) using SEM and dye penetration (2% methylene blue) in a comparative manner.Standardized class V-cavities (3 mm x 1.5 mm) were prepared in 70 extracted human teeth (n=10). The adhesives were applied according to manufacturers' instructions. The cavities were restored with three increments. After finishing and polishing (Sof-Lex discs) and thermocycling (5000x, 5/55 degrees C), replicas wer…
In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents
Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…
POSITIONING SELF-ETCHING ADHESIVES: VERSUS OR IN ADDITION TO PHOSPHORIC ACID ETCHING?
Two-year clinical performance of a packable posterior composite with and without a flowable composite liner
The aim of the study was to evaluate the clinical performance of a packable fine hybrid dental composite (Prodigy Condensable) and the influence of the additional application of a flowable resin composite (Revolution, SDS Kerr) layer on marginal integrity after 2 years in stress-bearing posterior cavities according to the Ryge criteria. In 50 patients (40.5+/-17.5 years of age), 116 class II fillings (metal matrix system, glass ionomer-cement-base in 36%, rubberdam isolation in 70%) were placed, with at least two restorations per patient. The adhesive Optibond Solo Plus was used for all the restorations. In one of the two fillings in each patient, an additional layer of the flowable composi…
Retentive strengths of cast gold crowns using glass ionomer, compomer, or resin cement
The retention forces of a newly developed compomer cement (Dyract Cem), a glass ionomer cement (Ketac Cem Aplicap), and a resin cement (F21) were examined.Cemented cast gold crowns were removed along the path of insertion with a Zwick universal testing device. The impact of both a cured and a noncured additional bonding layer that were applied to the inner surface of the crowns was examined across the Dyract Cem group.The mean adhesive strength was measured at 2.36 +/- 0.69 N/mm2 in the Ketac Cem group, at 0.60 +/- 0.28 N/mm2 in the F21 group, and at 1.85 +/- 0.94 N/mm2 in the Dyract Cem group, respectively. The application of an additional bonding layer to the inner surface of the crowns d…
OPTIONS FOR DENTIN BONDING
The Effects of Different Emoticons on the Perception of Emails in the Workplace
Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns
Abstract Statement of problem Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity. Purpose The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of …