PLS-UV spectrophotometric method for the simultaneous determination of paracetamol, acetylsalicylic acid and caffeine in pharmaceutical formulations
A simple and fast analytical procedure is proposed for the simultaneous determination of paracetamol, acetylsalicylic acid and caffeine in pharmaceuticals by means the partial least square treatment of the spectrophotometric absorbance data between 216 and 300 nm, taken at 5 nm intervals. The method involves the use of 8 standard mixtures of the three compounds assayed, considered at two concentration levels, and the measurement of the absorbance of samples in a 20% (v/v) ethanol in water solution previously filtered. In the analysis of real and synthetic samples precise and accurate values were obtained by the aforementioned procedure, providing in all cases variation coefficients and accu…
Clean method for the simultaneous determination of propyphenazone and caffeine in pharmaceuticals by flow injection Fourier transform infrared spectrometry.
A procedure is proposed for the simultaneous FTIR determination of propyphenazone (PFZ) and caffeine (CAF) in pharmaceuticals. The method involves the dissolution of the active principles in CHCl 3 , followed by filtration of sample solutions to remove the excipients. PFZ is then determined by absorbance measurements at 1595 cm - 1 , using a baseline established between 2000 and 890 cm - 1 , and CAF by using the first-derivative values at 1712 cm - 1 , using solutions of PFZ and CAF for external calibration. The method was applied in both the stopped-flow and flow-injection modes, providing precise and accurate results for the analysis of real samples. The incorporation of a distillation un…
Flow injection Fourier transform infrared determination of caffeine in coffee
Abstract A fully automatized procedure has been developed for the Fourier transform infrared (FT-IR) spectroscopic determination of caffeine in coffee samples. The method involves the on-line extraction of caffeine with CHCl3. Samples, weighed inside empty PTFE cartridges of 0.5 cm internal diameter (i.d.) and 1.5 ml volume, were humidified with four drops of 0.25 M NH3. The cartridge was installed in a flow manifold, in which samples were extracted in a closed-flow system with 1 ml CHCl3 during 6 min. Four hundred microliters of the extract were introduced in a microflow cell and absorbance measured as a function of time at 1659 cm−1, with a baseline established between 1900 and 830 cm−1, …