Liga Ozolina-moll

Development of a non-invasive LED based device for adipose tissue thickness measurements in vivo

There are a number of techniques for body composition assessment in clinics and in field-surveys, but in all cases the applied methods have advantages and disadvantages. High precision imaging methods are available, though expensive and non-portable, however, the methods devised for the mass population, often suffer from the lack of precision. Therefore, the development of a safe, mobile, non-invasive, optical method that would be easy to perform, precise and low-cost, but also would offer an accurate assessment of subcutaneous adipose tissue (SAT) both in lean and in obese persons is required. Thereof, the diffuse optical spectroscopy is advantageous over the aforementioned techniques. A p…

research product

Evaluation of a multispectral diffuse optical spectroscopy device for assessment of cardiometabolic risk related alterations of body composition

Cardiometabolic diseases encompass a combination of conditions which lead to an increase in the risk of cardiovascular disease and diabetes. With the increasing percentage of the population becoming overweight, it is important to diagnose when the excess adipose tissue becomes malign. The development of a safe, mobile, non-invasive method that would be easy to perform, and low-cost, but also would offer an accurate assessment of subcutaneous adipose tissue (SAT) both in lean and in obese persons is required. A prototype device using an optical method for measurement of the SAT in vivo has been developed, it contains multiple LEDs with four wavelengths (660nm, 780nm, 870nm, 940nm) distribute…

research product

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

research product

Comparative Analysis of the Effects of Daily Eating Habits and Physical Activity on Anthropometric Parameters in Elementary School Children in Latvia: Pach Study

Growing incidence of obesity and related diseases in children poses new challenges and calls for a review of lifestyle habits. This study aimed to assess daily eating habits (EH) and physical activity (PA) levels and identify their association with obesity in 8&ndash

research product