0000000000240787

AUTHOR

Luis García-ibáñez

showing 2 related works from this author

Advantages of binaural hearing provided through bimodal stimulation via a cochlear implant and a conventional hearing aid: a 6-month comparative stud…

2005

Our study data demonstrate the additional benefit derived from continued use of a contralateral hearing aid (HA) post-cochlear implantation for speech recognition ability in quiet and in noise. Postoperative bimodal stimulation is recommended for all subjects who show some speech recognition ability in the contralateral ear as it may offer binaural listening advantages in various listening situations encountered in everyday life.To assess the benefits derived from bimodal stimulation for experienced HA users implanted with a cochlear implant (CI) (score=20% in disyllabic test). The correlation between pre- and postoperative performance on speech perception measures was examined to determine…

Sound localizationHearing aidAdultmedicine.medical_specialtySpeech perceptionHearing lossmedicine.medical_treatmentHearing Loss SensorineuralAudiologyMonauralHearing AidsHearingCochlear implantotorhinolaryngologic diseasesmedicineHumansProspective StudiesAgedmedicine.diagnostic_testbusiness.industryAuditory ThresholdGeneral MedicineMiddle AgedCochlear ImplantsOtorhinolaryngologySpeech PerceptionAudiometry Pure-Tonemedicine.symptomAudiometrybusinessAudiometry SpeechNoiseBinaural recordingFollow-Up StudiesActa oto-laryngologica
researchProduct

Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipient…

2010

Abstract: The Nucleus CI24RE Freedom device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 μV. However, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C …

AdultPulse repetition frequencyLinguistics and Languagemedicine.medical_specialty3616 Speech and HearingLoudness Perceptionmedia_common.quotation_subjectAction PotentialsDifferential Threshold610 Medicine & health10045 Clinic for OtorhinolaryngologyStimulus (physiology)AudiologyCurvatureLanguage and LinguisticsLoudnessAutomationYoung AdultSpeech and HearingPerceptionmedicineHumansComfort levels1203 Language and LinguisticsAgedmedia_commonMathematicsPrincipal Component AnalysisAuditory ThresholdMiddle AgedElectric Stimulation3310 Linguistics and LanguageCochlear Implantsmedicine.anatomical_structurePulse rateAuditory PerceptionHuman medicineNoiseNucleus
researchProduct