0000000000242383

AUTHOR

Virginia Bernabé-zafón

Capillary electrophoresis enhanced by automatic two-way background correction using cubic smoothing splines and multivariate data analysis applied to the characterisation of mixtures of surfactants

Mixtures of the surfactant classes coconut diethanolamide, cocamido propyl betaine and alkylbenzene sulfonate were separated by capillary electrophoresis in several media containing organic solvents and anionic solvophobic agents. Good resolution between both the surfactant classes and the homologues within the classes was achieved in a BGE containing 80 mM borate buffer of pH 8.5, 20% n-propanol and 40 mM sodium deoxycholate. Full resolution, assistance in peak assignment to the classes (including the recognition of solutes not belonging to the classes), and improvement of the signal-to-noise ratio was achieved by multivariate data analysis of the time-wavelength electropherograms. Cubic s…

research product

Enzyme class identification in cleaning products by hydrolysis followed by derivatization with o-phthaldialdehyde, HPLC and linear discriminant analysis.

The enzymes present in raw materials of the cleaning industry (enzyme industrial concentrates) and in household cleaners were isolated by precipitation with acetone and hydrolyzed with HCl. The resulting amino acids were derivatized with o-phthaldialdehyde, and the derivatives were separated by HPLC. The peaks of 14 amino acids were observed using a C18 column and a multi-segmented gradient of acetonitrile-water in the presence of a 5 mM citric/citrate buffer of pH 6.5. Using either normalized peak areas (divided by the sum of the peak areas of the chromatogram) or ratios of pairs of peak areas as predictor variables, linear discriminant analysis models, capable of predicting the enzyme cla…

research product

Comparison on photo-initiators for the preparation of methacrylate monolithic columns for capillary electrochromatography.

The synthesis of lauryl methacrylate monoliths for capillary electrochromatography by UV polymerization using several free-radical initiators (alpha,alpha'-azobisisobutyronitrile, 2,2-dimethoxy-2-phenylacetophenone, dibenzoyl peroxide (BPO) and lauroyl peroxide (LPO)) has been investigated. Using a 1,4-butanediol/1-propanol mixture as porogenic solvent, the influence of each initiator and its content on the morphological and electrochromatographical properties of beds was evaluated. Under their respective optimum content, satisfactory separations of a test mixture of PAHs with similar efficiencies (minimum plate heights of 8.0-12.7 microm obtained from Van Deemter plots) were achieved for t…

research product

Photo-polymerized lauryl methacrylate monolithic columns for CEC using lauroyl peroxide as initiator

Lauryl methacrylate (LMA)-ester based monolithic columns photo-polymerized using lauroyl peroxide (LPO) as initiator were prepared, and their morphological and CEC properties were studied. The composition of the polymerization mixture (i.e. ratios of monomers/porogenic solvents, 1,4-butanediol/1-propanol and LMA/crosslinker) was optimized. The morphological and chromatographic properties of LMA columns were evaluated by means of SEM pictures and van Deemter plots of PAHs, respectively. The polymerization mixture selected as optimal provided a fast separation of a mixture of PAHs with excellent efficiencies (minimum plate heights of 8.9-11.1 μm). Satisfactory column-to-column (RS D < 4.5%) a…

research product

On the determination of underivatised fatty alcohol ethoxylates by electrospray ionisation–mass spectrometry

Abstract The oligomers of fatty alcohol ethoxylates (FAEs) exhibit large sensitivity differences in mass spectrometry with electrospray ionisation (ESI–MS) and atmospheric pressure chemical ionization (APCI). Standards of the oligomers from m = 1 to 7 ethylene oxide units (EOs) and linear alkyl chains from n = 10 to 18 carbon atoms were infused to examine the relative sensitivities or response factors in several media. The response factors of the [M + H]+ and [M + Na]+ peaks in 9:1 acetonitrile/water and methanol/water media containing acid buffers increased following irregular patterns when n and m increased. In methanol/water the response factors depended on the parity of m, being larger …

research product

Study of the Fragmentation of D-Glucose and Alkylmonoglycosides in the Presence of Sodium Ions in an Ion-Trap Mass Spectrometer

Abstract Using electrospray ion-trap mass spectrometry, the fragmentation of D-glucose and alkylmonoglycopyranosides (alkyl-GPs) was studied. In the presence of Na+, B1 and 0,2A fragmentations were observed. The alkyl-GPs also showed a 2,5Afragmentation. A cluster containing no carbon atoms and adducts of this cluster with neutral molecules were observed. Standards of alkylmonoglycofuranosides (alkyl-GFs) were not available; however, their fragmentation was studied by high-performace liquid chromatography–mass spectrometry (HPLC-MS) and HPLC-MS2 using an industrial mixture of alkylpolyglycosides. The cluster and its adducts were more easily formed by the alkyl-GPs than by the alkyl-GFs, but…

research product

Chromium(VI) oxide oxidation of non-ethoxylated and ethoxylated alcohols for determination by electrospray ionization mass spectrometry

A new derivatization procedure to increase the sensitivity of electrospray ionization mass spectrometry (ESI-MS) to non-ethoxylated and ethoxylated alcohols was investigated. The analytes were oxidized with chromium(VI) oxide and the resulting carboxylic and ethoxy-carboxylic acids were isolated by extraction with ethyl acetate; the extracts were alkalinized and infused into the ESI-MS system working in the negative-ion mode. The yields of the combined oxidation-extraction were ca. 100% for non-ethoxylated fatty alcohols dissolved in acetone and they decreased moderately in samples containing increasing amounts of water (e.g., a 75% yield was obtained with 50% water). Ethoxylated alcohols w…

research product

Study of elution behaviour with gradient voltage in CEC using methacrylate monolithic columns.

A theoretical study on the retention behaviour and chromatographic performance of neutral solutes using a lauryl methacrylate-based monolithic column under voltage gradient mode in CEC was carried out. Through a flexible mathematical function based on a modified Gaussian model, the peak shape of compounds was firstly fitted under constant and gradient voltage. Using the peak shape parameters and retention time, the estimation of global chromatographic performance, efficiency and peak capacity under several voltage conditions was performed. The influence of voltage gradient on the separation efficiency is discussed and simple equations are presented to calculate retention and peak widths und…

research product

Sensitive determination of polycyclic aromatic hydrocarbons in water samples using monolithic capillary solid-phase extraction and on-line thermal desorption prior to gas chromatography-mass spectrometry.

A methacrylate-based monolithic capillary column has been evaluated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. For this purpose, the monolyte was in situ synthesized in a 6cm×0.32mm id fused-silica capillary. The microextraction unit was fitted to a micro-HPLC pump to pass 10mL of sample. The isolated pollutants were eluted by means of 10μL of methanol, the organic phase being directly collected in a specific interface that can be fitted to the injection port of the gas chromatograph without modification. The interface allows the on-line thermal desorption of the PAHs, avoiding the dilution and providing enough sensitivity to reach …

research product

Characterization of industrial alkylpolyphosphonates by infusion electrospray ionization-ion trap mass spectrometry with identification of the impurities by tandem capillary zone electrophoresis

Technical grade diethylene-triaminepentakis(methylenephosphonic acid) (I), dihexamethylene-triaminepentakis(methylenephosphonic acid) (II), ethylene-diaminetetrakis(methylenephosphonic acid) (III), hexamethylene-diaminetetrakis(methylenephosphonic acid) (IV), amino-tris(methylenephosphonic acid) (V), hydroxyethyl-aminobis(methylenephosphonic acid) (VI), 1-hydroxyethylidene-1,1-diphosphonic acid (VII), and 2-phosphonobutane-1,2,4-tricarboxylic acid (VIII) were characterized by ion trap mass spectrometry with electrospray ionization (ESI-ITMS). Using the negative ion mode and acid and alkaline media, peak series corresponding to the nominal compounds and to impurities with a lower number of p…

research product

Separation and determination of alkylglycosides by liquid chromatography with electrospray mass spectrometric detection

The separation of alkylpolyglycosides by liquid chromatography with electrospray mass spectrometric detection, using either an alkylamide or a cyanopropyl column, and acetonitrile/water mixtures as mobile phases, was developed. Using the alkylamide column and isocratic elution, the alpha- and beta-epimers and ring isomers (pyranosides and furanosides) of the alkylmonoglycosides were resolved. The ring isomers were also resolved in a much shorter time using the cyanopropyl column with gradient elution. Using these columns, the isomers of the alkyldiglycosides and alkyltriglycosides were also partially resolved. The equilibration time was much shorter with the cyanopropyl column, which was se…

research product

Rapid characterization of alkylpolyphosphonates by CZE with indirect photometric and mass spectrometric detection.

Methods for the rapid characterization of industrial alkylpolyphosphonates (APPs) by infusion MS and CZE with indirect photometric (IPD) and MS detection are described. Technical-grade APPs, including alkylaminepolyphosphonates with 3-5 phosphonate groups and different hydrocarbon skeletons, hydroxyethyl-amino-bis(methylenephosphonic acid), hydroxyethylidene-diphosphonic acid, and 2-phosphonobutane-1,2,4-tricarboxylic acid, were examined. A 10 mM solution of adenosine triphosphate disodium salt at pH 2.2 was used as BGE. The nominal compounds of the industrial APPs and their impurities were well resolved in less than 15 min. The peaks were identified by using extracted ion electropherograms…

research product

Characterization and quantitation of mixtures of alkyl ether sulfates and carboxylic acids by capillary electrophoresis with indirect photometric detection

The separation, characterization, and determination of mixtures of alkyl ether sulfates (AES) and fatty acids (C10-C16) in background electrolytes (BGEs) containing acetonitrile (ACN)-water mixtures is addressed. Due to inhibition of the ionization of the carboxylate groups, the migration time and the resolution between the fatty acids decreased when the water content of the BGE was reduced, but efficiency and resolution between the AES oligomers improved. The migration times increased and resolution improved by substituting 5% ACN by an equivalent amount of dioxane. A complete separation of the two surfactant classes, up to the AES oligomers with 8 ethylene oxide units (EOs) with respect t…

research product

Resolution of overlapped non-absorbing and absorbing solutes using either an absorption null-balance detection window or multivariate deconvolution applied to capillary electrophoresis of anionic surfactants.

Abstract Non-absorbing alkyl ether sulfates (AES) can be separated using anthraquinone-2-carboxylic acid (AQCA) as a probe; however, absorbing alkyl benzene sulfonates (ABS), if present, interfere indirect detection of most AES oligomers. Overcoming of this interference, as well as the simultaneous characterisation and evaluation of AES, fatty acids and ABS, was accomplished by using a diode-array detector and the procedures here discussed. First, it was shown that ABS can be made undetectable by using a 9 nm wide and 227 nm centred charge-absorptivity null-balance detection window (NBDW), where its contribution to the absorbance cancels the dilution effects that its presence induces on the…

research product

Comparison of thermal&amp;hyphen; and photo&amp;hyphen;polymerization of lauryl methacrylate monolithic columns for CEC

Lauryl methacrylate-based (LMA) monolithic columns for CEC, prepared using either thermal initiation or by UV-irradiation in the presence of AIBN have been compared. Thermal polymerization was carried out at 70 degrees C for 20 h. For UV initiation, the effects of the time exposure to UV light and irradiation energy were investigated. For each initiation process, the influence of composition of porogenic solvent (1,4-butanediol/1-propanol ratio) on the physical and electrochromatographic properties of the resulting monoliths was also evaluated. Photochemically lauryl methacrylate stationary phases initiated showed higher permeabilities and better efficiencies than those prepared by thermal …

research product