0000000000248932

AUTHOR

Claus Peter Heussel

Functional Evaluation of Emphysema Using Diffusion-Weighted 3Helium-Magnetic Resonance Imaging, High-Resolution Computed Tomography, and Lung Function Tests

Purpose: To assess the emphysematous enlargement of distal air-spaces and concomitant large and small airway disease using diffusion-weighted 3 Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT). Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls. Patients were assessed by 3 Helium-MRI (apparent diffusion coefficient [ADC]), HRCT (mean lung density [MLD], emphysema index [El]), and LFT. Results: Transplanted lungs: mean ADC = 0.17 cm 2 /s, MLD = -848 H, El = 22%. Emphysematous lungs: mean ADC = 0.…

research product

Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement

OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beg…

research product

Influence of pixel size on quantification of airway wall thickness in computed tomography.

Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …

research product

Volumetry of Ventilated Airspaces by 3He MRI

To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…

research product

Phase II dose escalation study of caspofungin for invasive Aspergillosis.

ABSTRACT Our objective was to evaluate the maximum tolerated dose of caspofungin for invasive aspergillosis (IA). The safety and pharmacokinetics of escalating dosages of caspofungin were investigated in IA. Eight patients each received caspofungin 70, 100, 150, or 200 mg once a day (QD). Dose-limiting toxicity (DLT) was defined as the same non-hematological treatment-related adverse event of grade ≥4 in 2 of 8 patients or ≥3 in 4 of 8 patients in a cohort. A total of 46 patients (median age, 61 years; 21 female; 89% with hematological malignancies) received caspofungin (9, 8, 9, and 20 patients in the 70-, 100-, 150-, and 200-mg cohorts) for a median of 24.5 days. Plasma pharmacokinetics w…

research product

Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification.

Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (me…

research product

Segmentation and Navigation Support of Clinical Data Sets to Simulate the Bronchoscopy and Rhinoscopy

A training and simulation system for therapy planning is developed based on patient specific imaging data. A real endoscope is used for navigation through the virtual patient. For this purpose sensors were built in the endoscope in order to track the translation, rotation and the angle of the distal end. Pre-processing (segmentation, tissue characterization) speeds-up the volume rendering up to real-time. Collision detection enables a realistic fly through the virtual patient.

research product

Automatic detection and quantification of ground-glass opacities on high-resolution CT using multiple neural networks: comparison with a density mask.

We compared multiple neural networks with a density mask for the automatic detection and quantification of ground-glass opacities on high-resolution CT under clinical conditions.Eighty-four patients (54 men and 30 women; age range, 18-82 years; mean age, 49 years) with a total of 99 consecutive high-resolution CT scans were enrolled in the study. The neural network was designed to detect ground-glass opacities with high sensitivity and to omit air-tissue interfaces to increase specificity. The results of the neural network were compared with those of a density mask (thresholds, -750/-300 H), with a radiologist serving as the gold standard.The neural network classified 6% of the total lung a…

research product

Mikrostruktur der Lunge: Untersuchung mittels Diffusionsmessung von hochpolarisiertem 3Helium

Imaging methods to study the lung are traditionally based on x-ray or on radioactive contrast agents. Conventional magnetic resonance imaging (MRI) has only limited applications for lung imaging because of the low tissue density of protons concentration of hydrogen atoms, which are usually the basis for the imaging. The introduction of hyperpolarized noble gases as a contrast agent in MRI has opened new possibilities for lung diagnosis. The present paper describes this new technique. Diffusion-weighted MRI for assessment of the lung microstructure is presented here as an example of the new possibilities of functional imaging. Studies to determine the sensitivity of the diffusion measurement…

research product