0000000000266238

AUTHOR

H. Kaltenborn

showing 5 related works from this author

Zur Frage der Darmkontrastierung in der abdominellen Computertomographie

1992

In 56 patients undergoing abdominal CT the gastrointestinal tract was defined by negative contrast instead of the conventional positive contrast from an iodine containing contrast medium. The contrast material was a 2 1/2% mannitol solution and was used for filling the rectum. Filling of the gastrointestinal tract was of similar quality to that obtained with positive contrast media. The number of artifacts due to high contrast boundaries was slightly greater with the negative contrast than it would have been with positive contrast. Differentiation of the gastrointestinal tract from other abdominal organs was equally good for both methods. The negative contrast method was poor in diagnosing …

Gastrointestinal tractPathologymedicine.medical_specialtybusiness.industrymedia_common.quotation_subjectAbdominal ctRectumBarium mealContrast mediumNegative contrastmedicine.anatomical_structurePositive contrastMedicineContrast (vision)Radiology Nuclear Medicine and imagingbusinessNuclear medicinemedia_commonRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Radiologische Verlaufskontrolle der Thoraxorgane beim Intensivpflegepatienten

1991

Correlation between chest radiographs and clinical indicators was studied in 212 patients in intensive care. 1. There was good correlation between raised pulmonary artery pressure and radiological signs of left heart insufficiency, but not with the value of central venous pressure. 2. Fever and leukocytosis nearly always precede radiological evidence of pneumonia; their persistence does not necessarily indicate persistent pneumonia. 3. Pneumonias, effusions, atelectases and emboli are more common on the right. 4. More than 70% of central venous catheters were incorrectly placed; most commonly, the catheter was placed too low. Life-threatening complications occurred in 1.3%.

medicine.medical_specialtybusiness.industryRadiographyCentral venous pressuremedicine.diseaserespiratory tract diseasesSurgeryCatheterPneumoniaIntensive careRadiological weaponmedicine.arteryPulmonary arterymedicineRadiology Nuclear Medicine and imagingRadiologyLeukocytosismedicine.symptombusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Gadolinium-DTPA (Magnevist®) als Kontrastmittel für die Galaktographie

1995

business.industryMedicineRadiology Nuclear Medicine and imagingbusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Eine Nierenfunktionsanalyse durch die Computertomographie

1992

The CT clearance in a number of urological patients (39 patients, 25 with normal renal function) was studied by means of an "area under curve" (AUC) method, using a region of interest. 31 patients were given meglumine ioxithalamate and 8 patients Iopamidol as a contrast medium. Both for total and partial function there was highly significant correlation with isotope clearance with good reproducibility. The difference in the pharmacokinetics of the contrast media affected the absolute clearance values.

Reproducibilitymedicine.diagnostic_testbusiness.industryRenal functionComputed tomographyIopamidolNormal renal functionContrast mediumPharmacokineticsRegion of interestmedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicinemedicine.drugRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Kontrastmittel-Kurzinfusion oder -Bolusinjektion bei der i.v. Urographie

1993

The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the …

Kidneymedicine.diagnostic_testbusiness.industryComputed tomographyCollection systemContrast mediumBolus (medicine)medicine.anatomical_structureContrast injectionmedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicinePyelogramBolus injectionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct