showing 7 related works from this author

D.RE.A.M.: A software for uncertainties analysis in retrospective dosimetry

2018

Accidental exposures to ionising radiations are nowadays managed with assistance from biological and physical retrospective dosimetry which are able to provide individual estimates of dose absorbed by victims. The aim of this work is to describe the development of biodosimetry analysis software within the "EURADOS Working Group 10—Retrospective dosimetry" Task group 10.6. Methods The software has been developed in Python code language that is easy to learn, read, use and extensible (it is possible to add new modules). It can implement C/C++/Fortran, Java functions. It is embeddable in applications and is open source. It is extremely portable to Unix/Linux, Windows, Mac operating systems. Th…

retrospective dosimetry uncertainties analysis software pythonSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Uncertainty on radiation doses estimated by biological and retrospective physical methods

2018

International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…

medicine.medical_specialtyRadiology Nuclear Medicine and Imaging[SDV]Life Sciences [q-bio]Public Health and Health CareRadiation DosageRisk Assessment030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation MonitoringRadiation IonizingmedicineDosimetryHumansStatistical analysisMedical physicsRadiometryUncertainty analysisMathematicsRadiationRadiological and Ultrasound TechnologyPhysicsUncertaintyPublic Health Environmental and Occupational HealthGeneral Medicineretrospective dosimetry biodosimetry physical dosimetry uncertainityEuropeChemistryWork (electrical)030220 oncology & carcinogenesisRadiation monitoringBody BurdenRisk assessmentWhole bodyMathematicsHuman
researchProduct

EPR dosimetry intercomparison using smart phone touch screen glass

2014

International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…

medicine.medical_specialtySmart phoneMass casualty eventStatistics as TopicBiophysicsEPR dosimetry[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]EPR Dosimetry Elecron Paramagnetic Resonance in phone touch screen glass.01 natural sciencesRetrospective dosimetry030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTest material0103 physical sciencesmedicineHumansDosimetryMedical physicsRadiometryGeneral Environmental Science010302 applied physicsRadiationDosimeterbusiness.industryElectron Spin Resonance SpectroscopyRadiological emergencySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Critical levelHomogeneousCalibrationEpr dosimetryGlassbusinessNuclear medicine[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingCell Phone
researchProduct

Planning a new international comparison on EPR dosimetry with tooth enamel: a EURADOS WG10 proposal

2018

ntroduction L-a-alanine has aroused considerable interest for use in radiation ESR dosimetry. In this work, we examined the energy response of alanine ESR films in the low energy X-photon energy range between 1 keV and 40 keV. Dose measurements through a reference ionization chamber and a semiconductor detection system were also performed to complement ESR measurements. Methods Commercial alanine ESR films were used. All ESR signal measurements were also done using an XBand (9.7 GHz) Bruker spectrometer. The dosimeters were irradiated at the "Livio Scarsi" Laboratory (LAX) of the University of Palermo, where X-ray beams in the 1–40 keV energy range are produced using a Seifert SN60 tube. Re…

EPR ; dosimetry ; toothSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)EPR dosimetry EURADOS
researchProduct

REVIEW OF RETROSPECTIVE DOSIMETRY TECHNIQUES FOR EXTERNAL IONISING RADIATION EXPOSURES

2011

The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic re…

medicine.medical_specialtyProtein biomarkersOptically stimulated luminescence[SDV]Life Sciences [q-bio]Radiation DosageRisk AssessmentRetrospective dosimetry030218 nuclear medicine & medical imagingIonizing radiation03 medical and health sciences0302 clinical medicineRadiation MonitoringRadiation IonizingHumansMedicineDosimetryRadiology Nuclear Medicine and imagingMedical physicsRadiometryRetrospective StudiesRadiationRadiological and Ultrasound Technologybusiness.industryPublic Health Environmental and Occupational HealthGeneral MedicineIntegrated approach030220 oncology & carcinogenesisBody BurdenRadiation monitoringbusinessIonising radiation exposureRadiation Accidents
researchProduct

EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD

2004

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…

inorganic chemicalsSafety ManagementMaterials scienceQuality Assurance Health CareRadiation DosageRisk AssessmentSensitivity and Specificitylaw.inventionRadiation Protectionstomatognathic systemlawNuclear ReactorsRisk FactorsmedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronIrradiationElectron paramagnetic resonanceSpectroscopyRadiometryNeutronsObserver VariationRadiationRadiological and Ultrasound Technologybusiness.industryRadiochemistryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyReproducibility of ResultsGeneral MedicineReference StandardsTooth enamelEPR DOSIMETRY MIXED NEUTRON AND GAMMA RADIATION FIELDstomatognathic diseasesmedicine.anatomical_structureCriticalityGamma RaysAbsorbed doseBody BurdenFranceNuclear medicinebusinessRadioactive Hazard ReleaseRelative Biological Effectiveness
researchProduct

The 4th international comparison on EPR dosimetry with tooth enamel

2011

This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated s…

Detection limitMolarRadiationChemistryCalibration curvebusiness.industryTooth enamelKermamedicine.anatomical_structurestomatognathic systemCalibrationmedicineEpr dosimetryDosimetryNuclear medicinebusinessInstrumentationRadiation Measurements
researchProduct