Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detect…
Measuring the14C content in liquid scintillators
We are going to perform a series of measurements where the 14C/12 C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10-18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyhasalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyhasalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic 1…
Calibration strategy of the JUNO experiment
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination. [Figure not available: see fulltext.]
Measuring the 14C content in liquid scintillators
We are going to perform a series of measurements where the 14C/12C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10−18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyh¨asalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyh¨asalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic …
Towards 14C-free liquid scintillator
A series of measurements has been started where the 14C concentration is determined from several liquid scintillator samples. A dedicated setup has been designed and constructed with the aim of measuring concentrations smaller than 10−18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia, and in the new Callio Lab in the Pyhäsalmi mine, Finland. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic 14C concentration in the liquid is extremely low. In the Borexino CTF detector the concentration of 2 × 10−18 has been achieved being the lowest value ever measured. In principle, the older the oil or gas source that…
A New Low Background Laboratory in the Pyhäsalmi Mine : Towards 14C free liquid scintillator for low energy neutrino experiments
A new low background laboratory in Pyhäsalmi mine in the Central Finland has been put into operation in the beginning of 2017. The laboratory operates at the depth of 1436 m (~4100 meters of water equivalent). In this paper, we present description of the laboratory’s existing facility and background conditions. In the laboratory, a series of measurements has been started where the 14C concentration is determined from several liquid scintillator samples. A dedicated setup has been designed and constructed with the aim of measuring the 14C/12C ratio smaller than 10-18 . peerReviewed