0000000000324926

AUTHOR

J. Korner

The influence of bone allograft processing on osteoblast attachment and function

In order to assess the influence of eight different sterilisation and disinfection methods for bone allografts on adhesion, proliferation, and differentiation of human bone marrow stromal cells (BMSC), cells were grown in culture and then plated onto pieces of human bone allografts. Following processing methods were tested: autoclavation (AUT), low-temperature-plasma sterilisation of demineralised allografts (D-LTP), ethylene oxide sterilisation (EtO), fresh frozen bone (FFB), 80 degrees C-thermodisinfection (80 degrees C), gamma-irradiation (Gamma), chemical solvent disinfection (CSD), and Barrycidal-disinfection (BAR). The seeding efficiency was determined after one hour to detect the num…

research product

Osteosynthese am proximalen Humerus mittels winkelstabiler Platte oder Doppelplatte: eine vergleichende biomechanische Untersuchung / Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study

Internal fixation of fractures of the proximal humerus needs a high stability of fixation to avoid secondary loss of fixation. This is especially important in osteoporotic bone. In an experimental study, the biomechanical properties of the angle-fixed Philos plate (internal fixator) and a double-plate osteosynthesis using two one-third tubular plates were assessed. The fracture model was an unstable three-part fracture (AO type B2). Eight pairs of human cadaveric humeri were submitted to axial load and torque. In the first part of the study, it was assessed to which degree the original stiffness of the humeri could be restored after the osteotomy by the osteosynthesis procedure. Subsequentl…

research product

Three-dimensional distribution of trabecular bone density and cortical thickness in the distal humerus

One major barrier to osteosynthesis in distal humeral fractures is poor bone quality. This study was an attempt to measure the bone quality in the distal humerus.We measured the distribution of total bone mineral density (BMD), trabecular BMD (tBMD), and cortical thickness (CTh) in the distal humerus using peripheral quantitive computed tomography. Four slices in the infracondylar, supracondylar, and distal disphyseal regions of 25 human cadaver humeri were investigated.Total BMD decreased continuously from the distal diaphysis to the trochlea. Within the infracondylar region, the capitellum was the region of lowest tBMD and CTh (P.001). Measurements in anterior regions were higher than in …

research product

A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

OBJECTIVES To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN Basic science study. SETTING Experimental in vitro study. PATIENTS/PARTICIPANTS Forty fresh-frozen human distal humeri specimens. INTERVENTION Four matched groups with 10 humeri each, median age 74 years (46-95), were created using similar bone mineral density values. Two standard configurations of double-plate osteosynthesis (dorsal or 90 degrees configuration) with either conventional reconstruction plates or locking compression plates were studied for biomechanical properti…

research product

Primäre Ellenbogenprothese bei distalen Humerustrümmerfrakturen

The use of hip- and shoulder arthroplasty in elderly patients for grossly displaced intraarticular fractures is being more and more accepted. Total elbow replacement (TER) has not been considered as an option for the treatment of extensively comminuted fractures of the distal humerus because surgeons feel the outcome is not predictable after TER generally. On the basis of a Medline literature research of this issue and the documented results based on the improvement of the designs of the implants, operative technique and the selection of patients, TER has a definite role in the treatment of some fractures of the distal humerus. We retrospectively reviewed forty-nine acute distal humeral fra…

research product

Sind winkelstabile Plattensysteme mit elastischen Eigenschaften für die Stabilisierung der Oberarmkopffraktur vorteilhaft? / Eine in-vitro biomechanische Untersuchung

AbstractWinkelstabile Platten werden mit zunehmender Häufigkeit zur Stabilisierung von Oberarmkopfbrüchen verwendet. Rigide Implantate führen bei osteoporotischen Knochenverhältnissen u. U. aber häufiger zum Versagen. Um den Effekt der Implantatelastizität zu beurteilen wurden in einer in-vitro Studie die biomechanischen Eigenschaften eines rigiden und eines elastischen winkelstabilen Plattensystems vergleichend analysiert. An 8 Humeruspaaren wurde eine instabile subkapitale Fraktur simuliert. Die Proben wurden axial- und torsions-belastet. Analysiert wurden die Steifigkeit, das Setzverhalten unter Dauerlast und die Versagensbelastung.Das elastische Plattensystem kennzeichnete sich durch ei…

research product

Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior Stability? A Comparative Biomechanical In Vitro Study

Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…

research product