0000000000329494

AUTHOR

Gabriele Miccoli

One-stage laser-microtextured implants immediately placed in the inter-radicular septum of molar fresh extraction sockets associated with GBR technique. A case series study

Background The outcome of one-stage trans-mucosal immediate implants with simultaneous guided bone regeneration (GBR) technique has become highly predictable. Furthermore, when this approach is performed to place one-stage implants into the inter-radicular septum of fresh extraction sockets in the molar region, the risk of incorrect emergence profile and off-angle loading is reduced. The aim of the present study was to clinically evaluate the horizontal hard and soft tissue changes, and radiographically the vertical socket walls remodeling, and the early peri-implant marginal bone loss (EMBL) following the placement of immediate one-stage implants in the inter-radicular septum of molar fres…

research product

Full arch fixed prostheses vs. full arch telescopic-retained retrievable prostheses both supported by implants and natural tooth abutments in periodontally treated patients : results at 15 years

Background The clinical outcome of full arch fixed prostheses vs. full arch telescopic-retained retrievable prostheses supported by implants and natural tooth abutments in periodontally treated patients has been reported by few studies, with controversial results. The objective of this study was to evaluate long-term (15 years) complications of abutment teeth and dental implants in periodontally treated patients, rehabilitated with full arch telescopic-retained retrievable prostheses (TRP)s vs. full arch fixed prostheses (FP)s supported by teeth and implants. Material and methods After active periodontal therapy (non-surgical and surgical), and implant placement (replacement of hopeless tee…

research product

Symmetry of root and root canal morphology of mandibular incisors: A cone-beam computed tomography study

Background Aim of this study was to analyze the root canal configuration in mandibular central and lateral incisors in vivo using cone-beam computed tomography (CBCT) imaging. Material and methods A total of 487 mandibular central incisors and 491 mandibular lateral incisors from 250 patients were examined using CBCT imaging, previously taken for diagnosis and treatment. The number of roots, root canal system configuration, presence of apical confluences, distance between confluences and radiographic root end, symmetry between left and right elements were recorded and statistically analyzed. Results All the examined teeth presented only one root. No significant differences were found betwee…

research product

A comparative study of mechanical resistance of two reciprocating files

Background To evaluate the cyclic fatigue resistance of two different Nickel-Titanium instruments, Reziflow (Komet, Brasseler GmbH & Co., Lemgo, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods Two groups of 20 different NiTi endodontic instruments of identical tip size of 0.25 mm were tested; Reziflow and Wave-One Gold primary. Cyclic fatigue testing was performed in a stainless steel simulated root canal manufactured by reproducing the instrument’s size and taper. A simulated root canal with a 90 degrees angle of curvature and 5 mm radius of curvature was constructed for the instruments tested. The centre of the curvature was 5 mm from the tip …

research product

Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year

Background The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading. Material and Methods Thirty patients underwent to placement of a non-submerged implants with a laser-microtextured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured c…

research product