0000000000336047
AUTHOR
M. Zimmermann
Natural Forest Management in Neotropical Mountain Rain Forests — An Ecological Experiment
In tropical forests, the first step in the destruction cycle is usually the over-exploitation of high value timber, leading not only to extinction of the extracted species (Silva Matos and Bovi 2002) but also to the conversion of the forests into pastures in many cases (Wunder 1996b). In many highlands of Ecuador the productivity of the pastures is depleted due to the invasion of bracken fern (see Chapter 28 in this volume), which finally leads again to the conversion of primary forests by local farmers (Paulsch et al. 2001; Hartig and Beck 2003). This process usually is accompanied by loss of biodiversity (Brooks et al. 200 I), increased erosion, changes of hydrology (Bruijnzel 2004), and …
Abstract of the 68th Meeting (Spring Meeting) 6–9 March 1990, Heidelberg
SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study
Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…
Early outcomes and complications following cardiac surgery in patients testing positive for coronavirus disease 2019: An international cohort study
The outbreak of severe acute respiratory syndromecoronavirus-2, the cause of coronavirus disease 2019 (COVID-19) in December 2019 represented a global emergency accounting for more than 2.5 million deaths worldwide.1 It has had an unprecedented influence on cardiac surgery internationally, resulting in cautious delivery of surgery and restructuring of services.2 Understanding the influence of COVID-19 on patients after cardiac surgery is based on assumptions from other surgical specialties and single-center studies. The COVIDSurg Collaborative conducted a multicenter cohort study, including 1128 patients, across 235 hospitals, from 24 countries demonstrating perioperative COVID-19 infection…
Machine learning risk prediction of mortality for patients undergoing surgery with perioperative SARS-CoV-2: the COVIDSurg mortality score
The British journal of surgery 108(11), 1274-1292 (2021). doi:10.1093/bjs/znab183
Performance of the large scale HV-CMOS pixel sensor MuPix8
The Mu3e experiment is searching for the charged lepton flavour violating decay $ ��^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers of $50\, ��\text{m}$ thin High Voltage Monolithic Active Pixel Sensors (HV-MAPS) placed in a $1\,\text{T}$ magnetic field. The measurement of the trajectories of the decay particles allows for a precise vertex and momentum reconstruction. Additional layers of fast scintillating fibre and tile detec…
MuPix8 — Large area monolithic HVCMOS pixel detector for the Mu3e experiment
Abstract The requirements of the ultra thin pixel detectors for the Mu3e experiment at PSI can be achieved by the HVCMOS technology, which allows the design of fast monolithic detectors. The latest nearly full size prototype, MuPix8, has a size of about 1 × 2 cm 2 . The pixel readout circuitry was fully redesigned in comparison to the previous MuPix versions. MuPix8’s readout electronics implement a new concept with two comparators and two different operation modes. One mode uses two threshold voltages for time walk correction, the other is a ramp-ADC. First tests show a detection efficiency of 99.6% for 4 GeV electrons.