0000000000337254

AUTHOR

C. Schill

showing 15 related works from this author

Read-out electronics for fast photon detection with COMPASS RICH-1

2008

A new read-out electronics system has been developed for the fast photon detection of the central region of the COMPASS RICH-1. The project is based on multi-anode photomultipliers read out by the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1 TDC chip characterised by high time resolution. The system has been designed taking into account the high photon flux in the central region of the detector and the high rate requirement of the COMPASS experiment. The system is described in detail together with the measured performances. The new electronics system has been installed and used for the 2006 data taking; it entirely fulfils the expected performances.

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorChipParticle identificationOpticsCompassCOMPASS experimentElectronicsbusinessInstrumentationPhoton detection
researchProduct

The fast photon detection system of COMPASS RICH-1

2007

Abstract A fast photon detection system has been built for the upgrade of COMPASS RICH-1, the large size gaseous RICH detector in use at the COMPASS Experiment at the CERN SPS since 2001. The photon detectors of the central region have been replaced by a new system based on multi-anode photomultipliers coupled to individual fused silica lens telescopes and a fast readout electronics system, while in the outer region the existing MWPCs with CsI photocathodes have been equipped with a new readout system, based on the APV chip. RICH-1 has been successfully operated in its upgraded version during the 2006 run. We report on the upgrade design and construction, and on the preliminary characteriza…

PhotomultiplierNuclear and High Energy PhysicsPhotonMulti-anode photomultiplier tubesPhysics::Instrumentation and DetectorsUV lensesCOMPASS; Multi-anode photomultiplier tubes; Photon detection; RICH; UV lenses; Nuclear and High Energy Physics; InstrumentationCOMPASSlaw.inventionFAST-RICH; DEUTERON; READOUT; DESIGNOpticsDESIGNlawMulti-anode photomultiplier tubeCompassCOMPASS experimentRICHInstrumentationNuclear and High Energy PhysicPhysicsLarge Hadron Colliderbusiness.industryDetectorREADOUTDEUTERONLens (optics)UpgradePhoton detectionFAST-RICHUV lenseHigh Energy Physics::Experimentbusiness
researchProduct

Pattern recognition and PID for COMPASS RICH-1

2008

A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure and algorithms, and the detector characterization and PID results.

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhysics - Instrumentation and Detectorsbusiness.industryPhoton detectorDetectorPID controllerFOS: Physical sciencesPattern recognitionInstrumentation and Detectors (physics.ins-det)Photon yieldParticle identificationHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)CompassPattern recognition (psychology)Artificial intelligenceDetectors and Experimental TechniquesbusinessInstrumentation
researchProduct

Design and status of COMPASS FAST-RICH

2006

In the context of the upgrade of COMPASS RICH-1, we are developing a fast photodetection system for RICH counters, based on UV extended Multi-Anode PhotoMultiplier Tubes (MAPMT) and a custom, low dead-time electronic readout system. Photons are concentrated on the MAPMT photocathode by an optical system that preserves the position information. The ratio between the collection and the photosensitive surfaces is ∼7.5 in our design, larger than in previous applications. A new front-end electronics, based on a modified version of the MAD4 discriminator chip, is being realized to digitize the MAPMT signals. We report about the design of the photodetection system and of the associated electronic …

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryContext (language use)PhotodetectionChipPhotocathodeOpticsUpgradeCompassElectronicsbusinessInstrumentation
researchProduct

Particle identification with COMPASS RICH-1

2011

International audience; RICH-1 is a large size RICH detector in operation at the COMPASS experiment since 2001 and recently upgraded implementing a new photon detection system with increased performance.A dedicated software package has been developed to perform RICH-1 data reduction, pattern recognition and particle identification as well as a number of accessory tasks for detector studies.The software package, the algorithms implemented and the detector characterisation and performance are reported in detail.

Nuclear and High Energy PhysicsPhysics::Instrumentation and Detectors[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesCOMPASSParticle identificationParticle identificationCompass0103 physical sciencesCOMPASS experimentComputer vision010306 general physicsInstrumentationRICHPhysics010308 nuclear & particles physicsbusiness.industryDetectorSoftware packageParticle identification; COMPASS; Likelihood algorithmsPattern recognition (psychology)High Energy Physics::ExperimentArtificial intelligenceLikelihood algorithmsbusinessPhoton detectionData reduction
researchProduct

The fast readout system for the MAPMTs of COMPASS RICH-1

2007

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultiplie…

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhysics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsbusiness.industryDetectorPhoton fluxFOS: Physical sciencesReadout electronicsInstrumentation and Detectors (physics.ins-det)ChipParticle identificationUpgradeOpticsCompassDetectors and Experimental TechniquesbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Particle identification with the fast COMPASS RICH-1 detector

2009

International audience; A new photon detection system for the COMPASS RICH-1 detector has been designed and installed. In the central region, the project is based on multi-anode photo-multiplier technology accompanied by charge sensitive, high resolution and dead-time free time digitization. In the outer area, only the readout electronics for the existing photon detectors has been replaced. Details on the detector upgrade and its performance are presented.

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsPhoton detectorMulti-anode photo-multiplierComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONHigh resolution[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesCOMPASSParticle identificationTDCParticle identificationOpticsCompass0103 physical sciences010306 general physicsInstrumentationRICHPhysics010308 nuclear & particles physicsbusiness.industryDetectorCharge (physics)Front-end electronicsUpgradeCOMPASS; RICH; Multi-anode photo-multiplier; Particle identification; Front-end electronics; TDCHigh Energy Physics::ExperimentbusinessPhoton detectionFront-end electronic
researchProduct

The experience of building and operating COMPASS RICH-1

2010

COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at CERN SPS. It uses a 3 m long C(4)F(10) radiator, a 21 m(2) large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m(2). It is in operation since 2002 and its performance has increased in time thanks to progressive optimization and mostly to a major upgrade which was implemented in 2006. The main characteristics of COMPASS RICH-1 components are described and some specific aspects related to the radiator gas system, the mirror alig…

Nuclear and High Energy PhysicsCherenkov detectorPhysics::Instrumentation and Detectors[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]COMPASS01 natural sciencesParticle identificationParticle identificationlaw.inventionNuclear physicsCOMPASS; CsI; MAPMT; Photon detection; PID; RICH; Instrumentation; Nuclear and High Energy PhysicsOpticslawCompass0103 physical sciencesCOMPASS experimentCsI photoconverter010306 general physicsRICHInstrumentationEvent reconstructionPhysicsLarge Hadron ColliderSpectrometer010308 nuclear & particles physicsbusiness.industryPIDUpgradePhoton detectionMAPMTCsIParticle identification; COMPASS; RICH; MAPMT; CsI photoconverterHigh Energy Physics::Experimentbusiness
researchProduct

The COMPASS RICH-1 fast photon detection system

2008

Abstract A fast photon detection system has been built as a part of the upgrade of the COMPASS RICH-1 detector: it is based on 576 multi-anode photomultiplier tubes (MAPMTs) coupled to individual fused silica lens telescopes and fast readout electronics. This system has replaced the MWPCs with CsI photo-cathodes in the central region ( 1.3 m 2 , 25% of the total area) of the COMPASS RICH-1 photon detectors and has successfully been operated during the data taking in 2006 and 2007. We report about the fast photon detection system design, construction and commissioning, in particular about the design optimization and the validation tests of the lens telescopes. Preliminary values for the incr…

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhysics::Instrumentation and Detectorsbusiness.industryPhoton detectorDetectorlaw.inventionLens (optics)OpticsUpgradelawCompassSystems designOptoelectronicsHigh Energy Physics::ExperimentbusinessInstrumentationPhoton detectionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The characterisation of the multianode photomultiplier tubes for the RICH-1 upgrade project at COMPASS

2008

Abstract A major upgrade of the Cherenkov photon detection system of COMPASS RICH-1 has been performed and it has been in operation since the 2006 physics run. The inner part of the photon detector has been replaced by a different technology in order to measure Cherenkov photons at high photoelectron rates, up to several times 10 6 per second and per channel. Cherenkov photons from 200 to 750 nm are detected by 576 multianode photomultiplier tubes (MAPMTs) with 16 channels each, coupled to individual fused silica lens telescopes and fast, high sensitivity and high time resolution electronics read-out. To guarantee an optimal performance of the complete system, parameters like dark current, …

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhotonPhysics::Instrumentation and Detectorsbusiness.industryDetectorOpticsUpgradeCompassQuantum efficiencybusinessInstrumentationCherenkov radiationDark current
researchProduct

Study of Σ(1385) and Ξ(1321) hyperon and antihyperon production in deep inelastic muon scattering

2013

Large samples of \Lambda, \Sigma(1385) and \Xi(1321) hyperons produced in deep-inelastic muon scattering off a ^6LiD target were collected with the COMPASS experimental setup at CERN. The relative yields of \Sigma(1385)^+, \Sigma(1385)^-, \bar{\Sigma}(1385)^-, \bar{\Sigma}(1385)^+, \Xi(1321)^-, and \bar{\Xi}(1321)^+ hyperons decaying into \Lambda(\bar{\Lambda})\pi were measured. The heavy hyperon to \Lambda and heavy antihyperon to \bar{\Lambda} yield ratios were found to be in the range 3.8% to 5.6% with a relative uncertainty of about 10%. They were used to tune the parameters relevant for strange particle production of the LEPTO Monte Carlo generator.

disParticle physicsStrange quarkdis; hyperon productionPhysics and Astronomy (miscellaneous)diLambda01 natural sciencesCOMPASSHigh Energy Physics - Experimenthyperon production0103 physical sciencesCHARGED CURRENT INTERACTIONSCHARGED CURRENT INTERACTIONS; (LAMBDA)OVER-BAR POLARIZATION; COMPASS010306 general physicsNuclear ExperimentEngineering (miscellaneous)Nuclear ExperimentPhysicsMuon010308 nuclear & particles physicsGenerator (category theory)High Energy Physics::PhenomenologyHyperon(LAMBDA)OVER-BAR POLARIZATIONSigmaProduction (computer science)High Energy Physics::ExperimentParticle Physics - ExperimentBar (unit)
researchProduct

The COMPASS experiment at CERN

2007

The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both…

Nuclear and High Energy Physicsstraw tube detectorPhysics::Instrumentation and DetectorsProject commissioningFOS: Physical sciencesfixed-target experimentRICH detectorhadron structureHigh Energy Physics - ExperimenttargetMWPCNuclear physicsHigh Energy Physics - Experiment (hep-ex)CompassHadron spectroscopyCOMPASS experimentscintillating fibre detectorNuclear Experimentsilicon microstrip detectorsInstrumentationSilicon microstrip detectorsPhysicsLarge Hadron ColliderStructure functionMicroMegas detectorfront-end electronicsDAQmicromegas detectordrift chamberPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentpolarisedGEM detectorcalorimetryParticle Physics - Experimentpolarised DISNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Fast photon detection for COMPASS RICH-1

2007

A fast photon detection system has been built and assembled for the upgrade of COMPASS RICH-1. The system is based on multianode photomultipliers coupled to fused silica lenses to collect the light from a larger surface and to guide it to the photocathode, preserving the position information. The emphasis is on the fast response and high rate capability of the detectors and the associated electronics. The photon detection system is now ready and it will be employed in the 2006 COMPASS data taking. We report about the system design and construction.

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryUV lensesEmphasis (telecommunications)DetectorCOMPASSPhotocathodeOpticsUpgradePhoton detectionCompassCOMPASS; RICH; Multianode photomultiplier tubes; UV lenses; Photon detectionMultianode photomultiplier tubesSystems designElectronicsbusinessInstrumentationRICH
researchProduct

A highly integrated low-cost readout system for the COMPASS RICH-1 detector

2007

Particle identification at high multiplicities is a key feature of the COMPASS experiment at CERN's SPS. Hadrons up to 50 GeV/c are identified by a RICH detector with a large horizontal and vertical acceptance of plusmn250 mrad and plusmn180 mrad, respectively. The central region of the photon detector is equipped with multi-anode photomultiplier tubes, the remaining 75% of the total active area are covered by MWPCs with Csl photocathodes. In order to improve the performance of the detector at very high beam intensities, more than 62000 channels of a new analog readout system of the MWPCs, based on the APV25 chip, were developed and installed in 2006. The new system features good single pho…

PhysicsPhotomultiplierPhysics::Instrumentation and Detectorsbusiness.industryDetectorPhotodetectorDead timeParticle identificationNuclear physicsOpticsCompassNuclear electronicsCOMPASS experimentHigh Energy Physics::Experimentbusiness2007 IEEE Nuclear Science Symposium Conference Record
researchProduct

Measurement of the Charged-Pion Polarizability

2015

The COMPASS collaboration at CERN has investigated pion Compton scattering, $\pi^-\gamma\rightarrow \pi^-\gamma$, at centre-of-mass energy below 3.5 pion masses. The process is embedded in the reaction $\pi^-\mathrm{Ni}\rightarrow\pi^-\gamma\;\mathrm{Ni}$, which is initiated by 190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, $Q^2<0.0015$\,(GeV/$c$)$^2$. From a sample of 63\,000 events the pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\ 0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times 10^{-4}\,\mbox{fm}^3$ under the …

Particle physicsChiral perturbation theoryPhotonComputerSystemsOrganization_COMPUTERSYSTEMIMPLEMENTATIONStrong interactionComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONGeneral Physics and AstronomyFOS: Physical sciencesComputerApplications_COMPUTERSINOTHERSYSTEMSGeneralLiterature_MISCELLANEOUSHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)PionPolarizabilityNuclear Experiment (nucl-ex)Nuclear ExperimentNuclear ExperimentPhysicsChPTMuonCompton scatteringpolarisabilitypolarisability; ChPTComputingMethodologies_PATTERNRECOGNITIONHigh Energy Physics::ExperimentMagnetic dipoleParticle Physics - Experiment
researchProduct