Visual Comparison of an Artificial Pupil Contact Lens to Monovision

2012

PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual AcuityPupilVision MonocularOphthalmologymedicineHumansContrast (vision)media_commonMathematicsCross-Over StudiesPupilEquipment DesignPresbyopiaMiddle Agedeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment OutcomeFemaleSpatial frequencymedicine.symptomFollow-Up StudiesOptometryPhotopic visionOptometry and Vision Science
researchProduct

Effect of multizone refractive multifocal contact lenses on the Cirrus HD OCT retinal measurements

2011

Background Simultaneous vision multifocal contact lenses are widely used to alleviate the symptoms of presbyopia. These contact lenses create simultaneous retinal images due to the incoming light distribution being divided into two or more focuses. Our aim was to evaluate whether the multizone refractive multifocal contact lenses affect the measurements of the retinal nerve fibre layer (RNFL) and macular thickness using optical coherence tomography (OCT). Methods In this cross-over study, 30 eyes of 30 subjects with a mean age of 50.42 ± 7.82 years were fitted with multizone refractive multifocal contact lenses. Using the RNFL Thickness Analysis mode of the Cirrus HD (Carl Zeiss, Meditec, D…

MaleRetinal Ganglion Cellsmedicine.medical_specialtyMaterials sciencegenetic structuresContact LensesVisual AcuityRefraction Ocularchemistry.chemical_compoundNerve FibersOpticsOptical coherence tomographySignal strengthOphthalmologymedicineHumansÓpticaCross-Over Studiesmedicine.diagnostic_testbusiness.industryRetinalEquipment DesignPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractioneye diseasesContact lensOphthalmologychemistryOftalmologíaFemaleCirrussense organsTomographybusinessTomography Optical CoherenceOptometryClinical and Experimental Optometry
researchProduct

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2012

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…

MaleVisual acuitygenetic structuresDesenho de prótesesmedicine.medical_treatmentVisual AcuityEmmetropiaIntraocular lensProsthesis designMyopia/surgerylaw.inventionNear visionLens Implantation Intraocularlcsh:OphthalmologylawTonometry ocularMyopiaProspective StudiesLenses IntraocularLens crystalline/surgeryAcuidade visualGeneral MedicineMiddle AgedLens (optics)HyperopiaTreatment OutcomeFemalemedicine.symptomLens crystallinemedicine.medical_specialtyVisual acuityMiopiaRefractive lens exchangeProsthesis DesignStatistics NonparametricOphthalmologyLens CrystallinemedicineHumansHyperopia/physiopathologyHipermetropiaCristalinoAgedPhacoemulsificationbusiness.industryReproducibility of ResultsPhacoemulsificationPresbyopiamedicine.diseaseeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994OptometryImplantação de lentes intraocularessense organsbusinessArquivos Brasileiros de Oftalmologia
researchProduct

Efficacy and Safety of Mass Cataract Surgery Campaign in a Developing Country

2012

To determine the visual outcomes achieved in terms of efficacy and safety during a mass eye surgery campaign in a low-income developing country.Three hundred fifteen eyes of 305 patients underwent extracapsular cataract extraction with intraocular lens implantation in a prospective, analytical, experimental, and nonrandomized study on patients who underwent cataract surgery during the campaign that two Spanish nongovernmental organizations conducted in December 2008 in a district hospital in Bobo-Dioulasso (Burkina Faso).Mean age was 61.97 ± 14.39 years. The mean uncorrected distance visual acuity before surgery was 2.17 ± 0.7 (20/3000), which improved to 0.86 ± 0.64 logMAR (20/150) 3 month…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityDeveloping countryIntraocular lensCataract ExtractionCataractCataract extractionLens Implantation IntraocularBurkina FasomedicineHumansProspective StudiesEye surgeryProspective cohort studyDeveloping Countriesbusiness.industryFollow up studiesMiddle AgedCataract surgeryeye diseasesSurgeryOphthalmologyTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Impact of contact lens material and design on the ocular surface.

2018

BACKGROUND: To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. METHODS: The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. RESULTS: The nesofilcon A was shown to be the thinnest lens…

Lentes de contacto desechablesAdultMaleContact lens materialMaterials sciencegenetic structuresSurface PropertiesProsthesis Designcomplex mixturesHydrogel Polyethylene Glycol Dimethacrylatelaw.inventionCornea03 medical and health sciencesYoung Adult0302 clinical medicineCorneal edemalawMyopiaHumansDisposable EquipmentOsmolar Concentrationtechnology industry and agricultureEquipment DesignDaily wearContact Lenses HydrophilicColoideseye diseasesContact lensLens (optics)OphthalmologyTear meniscusTears030221 ophthalmology & optometryOftalmologíaDaily disposableFemalesense organsOcular surfaceConjunctiva030217 neurology & neurosurgeryOptometryBiomedical engineeringClinicalexperimental optometry
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Corneal thickness differences between sexes after oxybuprocaine eye drops.

2014

PURPOSE We aimed to analyze the corneal thickness (CT) values of female and male subjects before and after instillation of oxybuprocaine 0.4% anesthetic eye drops. METHODS The CT of 30 female subjects and 28 male subjects was measured using scanning-slit corneal topography (Orbscan Topography System II, Orbscan, Inc, Salt Lake City, UT). Measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 0.4% eye drops. RESULTS The difference between the baseline values and those obtained after anesthesia ranged as follows: male subjects: central, -26 to +24 μm; superior, -24 to +23 μm; inferior, -19 to +20 μm; nasal, -25 to +30 μm; and temporal, -21 to +20 μm; female…

AdultMalemedicine.medical_specialtyAdolescentSalt lakeCorneaYoung AdultSex FactorsOphthalmologymedicineHumansProspective StudiesOxybuprocaineAnesthetics LocalBaseline valuesmedicine.diagnostic_testbusiness.industryCorneal TopographyOrgan SizeCorneal topographyOphthalmologyAnestheticFemaleOphthalmic SolutionsbusinessProcaineOptometrymedicine.drugOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.

2011

Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…

MaleVisual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivitymedicineContrast (vision)HumansMathematicsmedia_commonAgedVision BinocularCross-Over StudiesColor VisionEquipment DesignPresbyopiaMiddle Agedeye diseasesStereoscopic acuityContact lensOphthalmologyStereopsisTreatment OutcomeOptometryFemalemedicine.symptomBinocular visionOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.

2011

Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisCataract ExtractionRefraction OcularBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses Intraocularmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyGeneral MedicineMultifocal intraocular lensMiddle AgedCorneal topographySubjective refractionRefractioneye diseasesOphthalmologyHyperopiaFemalesense organsbusinessEuropean journal of ophthalmology
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system

2014

Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…

AdultMaleChord (geometry)medicine.medical_specialtyCorneal Wavefront AberrationCorneal Pachymetrygenetic structuresIntraclass correlationScheimpflug principleDiagnostic Techniques OphthalmologicalAstigmatismRefraction OcularCorneaYoung AdultOpticsOphthalmologyPhotographymedicineHumansProspective StudiesCorneal pachymetryDioptreMathematicsObserver VariationWavefrontmedicine.diagnostic_testbusiness.industryReproducibility of ResultsRepeatabilitymedicine.diseaseHealthy Volunteerseye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Contrast sensitivity and color perception with orange and yellow intraocular lenses

2012

To evaluate contrast sensitivity function (CSF) and color vision after implantation of either orange or yellow-tinted intraocular lenses (IOLs).Fifty-six eyes of 28 cataract patients who had bilateral implantation of orange-tinted (PC440Y Orange, Ophtec), yellow-tinted (AcrySof Natural SN60AT, Alcon), or clear (AcrySof SA60AT, Alcon) IOLs were examined. Six months postoperatively, monocular CSF under photopic and mesopic (with and without glare) conditions were measured using the Functional Visual Analyzer. Color discrimination was determined with the Farnsworth-Munsell 100-Hue test.Patients implanted with orange-tinted, yellow-tinted, or clear IOLs displayed similar CSF values, with no sta…

Male0301 basic medicinemedicine.medical_specialtygenetic structuresColor visionmedicine.medical_treatmentMesopic VisionVisual AcuityOrange (colour)Prosthesis DesignColor discriminationContrast Sensitivity03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOphthalmologyHumansMedicineProsthesis designProspective StudiesAgedLenses IntraocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationeye diseasesOphthalmology030104 developmental biologyIntraocular lenses030221 ophthalmology & optometryFemalesense organsbusinessColor PerceptionEuropean Journal of Ophthalmology
researchProduct

Diurnal variations in visual performance for disposable contact lenses.

2013

The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …

AdultMaleVisual acuitygenetic structuresmedia_common.quotation_subjectVisual AcuityContrast SensitivityYoung AdultmedicineMyopiaContrast (vision)HumansDisposable EquipmentVision Ocularmedia_commonMathematicsContact Lenses Hydrophiliceye diseasesCircadian RhythmOphthalmologyOptometryDaily disposableFemalesense organsDisposable Equipmentmedicine.symptomOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2013

Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…

Malegenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensMyopia/surgerylaw.inventionLens Implantation Intraocularlcsh:OphthalmologylawMyopiaContrast (vision)Prospective StudiesDioptreMathematicsmedia_commonLenses Intraoculareducation.field_of_studyGeneral MedicineMiddle AgedFacoemulsificaciónLens (optics)HiperopiaHyperopiaFemalePhotopic visionmedicine.medical_specialtyMiopíaVisual acuitymedia_common.quotation_subjectPopulationCataract ExtractionContrast SensitivityVision MonocularOphthalmologyImplantación de lentes intraocularesmedicineHumansHyperopia/physiopathologyAgudeza visualeducationCristalinoAgedMonocularPhacoemulsificationDistance PerceptionLens cristalline/surgeryeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994Optometrysense organs
researchProduct

Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser

2011

PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…

Adultmedicine.medical_specialtyCorneal endotheliumgenetic structuresEndotheliummedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCell CountKeratomileusisRefraction OcularYoung AdultOphthalmologyMyopiamedicineHumansProspective StudiesDioptrebusiness.industryEndothelium CornealLASIKCorneal Endothelial Cell LossContact Lenses Hydrophiliceye diseasesSurgeryContact lensOphthalmologymedicine.anatomical_structureLens (anatomy)FemtosecondLasers ExcimerSurgerysense organsbusinessJournal of Refractive Surgery
researchProduct

Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…

2010

Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …

AdultMaleVisual acuityCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical FlapsYoung AdultPostoperative ComplicationsMicrokeratomeRefractive surgeryCorneamedicineMyopiaHumansProspective Studiesmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographyeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structurePrivate practiceOptometrySurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry

2012

PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…

Malemedicine.medical_specialtygenetic structuresContact LensesOpticsCLs upper limitsPattern standard deviationOphthalmologymedicineHumansMathematicsCross-Over Studiesbusiness.industryAutomated perimetryPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractive lensCrossover studyeye diseasesVisual fieldAbsolute deviationOphthalmologySensory ThresholdsVisual Field TestsFemaleVisual FieldsbusinessAlgorithmsEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

2011

Purpose To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Setting Private practice surgery center, Valencia, Spain. Design Cohort study. Methods Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. Results In the multifocal group, the mean binocular …

Malemedicine.medical_specialtygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVision DisordersVisual AcuityIntraocular lensProsthesis DesignCohort StudiesContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesmedicineContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)PhacoemulsificationMultifocal intraocular lensMiddle Agedeye diseasesSensory SystemsOphthalmologyPrivate practiceQuality of LifeOptometrySurgeryFemalesense organsbusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual performance of two simultaneous vision multifocal contact lenses

2012

Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…

AdultMaleVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual Acuitylaw.inventionContrast SensitivitylawmedicineHumansContrast (vision)media_commonVision BinocularCross-Over Studiesbusiness.industryIntermediate distanceBoth lensesPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyOptometryFemalemedicine.symptombusinessOptometryPhotopic visionOphthalmic and Physiological Optics
researchProduct

Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.

2011

Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…

Malemedicine.medical_specialtyOptics and PhotonicsVisual acuityMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMedicineContrast (vision)Humansmedia_commonAgedAged 80 and overLenses Intraocularbusiness.industryStrehl ratioGeneral MedicineMiddle AgedOphthalmologySpherical aberrationFemalemedicine.symptombusinessPhotopic visionEuropean journal of ophthalmology
researchProduct

Visual quality differences between orthokeratology and LASIK to compensate low-moderate myopia.

2013

PURPOSE: To assess the differences in visual performance between orthokeratology (ortho-k) and laser in situ keratomileusis (LASIK) for the treatment of low-to-moderate myopia. METHODS: An adaptive optics visual simulator (Imagine Eyes) was used to simulate the wavefront aberration patterns induced by ortho-k and LASIK for low and moderate myopia on 10 healthy eyes. Visual acuity (VA) at 100%, 50%, and 10% contrast levels and contrast sensitivity (CS) at 10, 20 and 25 cycles per degree (cpd) were then measured for 3- and 6-mm pupil sizes. RESULTS: Differences in VA for 3-mm pupil diameter were not found between ortho-k and LASIK. For 6-mm pupil size, LASIK provided significantly better VA v…

AdultMalemedicine.medical_specialtyVisual acuitymedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityKeratomileusisPupilCycles per degreeContrast SensitivityYoung AdultOphthalmologyMyopiaMedicineContrast (vision)Humansmedia_commonAnalysis of Variancebusiness.industryOrthokeratologyPupil sizeLASIKOphthalmologyFemalemedicine.symptombusinessOrthokeratologic ProceduresCornea
researchProduct

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

2011

Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmu…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentToric phakic intraocular lensNystagmusPhakic intraocular lenseye diseasesMyopic astigmatismOphthalmologyLeft eyeNystagmuslcsh:OphthalmologyOphthalmologic examinationlcsh:RE1-994OphthalmologyRefractive surgeryMedicineIn patientPublished: August 2011sense organsmedicine.symptomRefractive surgerybusinessCongenital nystagmusCase Reports in Ophthalmology
researchProduct

Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

2014

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…

AdultMalemedicine.medical_specialtyAnterior ChamberScheimpflug principlePupil diameterIrisVergenceDiagnostic Techniques OphthalmologicalPupilAnterior chamber angleNear visionAnterior chamber eyeYoung AdultOpticslcsh:OphthalmologyOphthalmologyPhotographyMedicineHumansskin and connective tissue diseasesPupilaAnterior chamberCâmara anteriorTécnicas medidas equipamentos de mediçãobusiness.industryAccommodation OcularPupilGeneral Medicineeye diseasesOphthalmologyAcomodação ocularlcsh:RE1-994Accommodation ocularTechniques measures measurement equipmentFemalesense organsbusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.

2019

To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…

MaleCorneal Wavefront AberrationPseudophakiaMesopic visionZernike polynomialsmedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPupillaw.inventionsymbols.namesakeLens Implantation IntraocularlawmedicineHumansProspective StudiesRetinoscopyMathematicsAgedPhacoemulsificationmedicine.diagnostic_testKeratometerAberrometryMiddle AgedMultifocal Intraocular LensesSensory SystemsOphthalmologyAutorefractorsymbolsOptometrySurgeryFemalePhotopic visionJournal of cataract and refractive surgery
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.

2014

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

Point spread functionAdultLaser de excimerPhakic Intraocular LensesVisual acuityVisual acuitymedicine.medical_treatmentKeratomileusis Laser In SituLentes intraoculares; Sensibilidade de contrasteVisual AcuityCeratomileuse assistida por excimer laser in situ/métodosKeratomileusisPhakic intraocular lensMyopia/surgeryPupilKeratomileusis laser in situ/methodsContrast SensitivityYoung Adultlcsh:OphthalmologyLens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansComputer SimulationContrast sensitivityAdaptive opticsSimulationPhysicsLasers excimer/therapeutic useAcuidade visualAberrometryAccommodation OcularGeneral MedicineOphthalmologyTreatment Outcomelcsh:RE1-994Lenses intraocularMiopia/cirurgiaOptometrySpatial frequencymedicine.symptomArquivos brasileiros de oftalmologia
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes

2011

Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…

AdultMalemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuitygenetic structuresCorneal Stromamedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical Flapslaw.inventionCohort StudiesYoung AdultlawRefractive surgeryOphthalmologyMyopiamedicineHumansDioptreRetrospective Studiesbusiness.industryLASIKMiddle AgedLaserAblationeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

2017

Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…

medicine.medical_specialtygenetic structuresSpherical equivalentMean differencelaw.invention03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical ResearchlawOphthalmologymedicineDioptreKeratometerbusiness.industry1733autorefractionvector analysisRepeatabilityMultifocal intraocular lensRefractioneye diseasesOphthalmologylcsh:RE1-994Autorefractor030221 ophthalmology & optometrymultifocal intraocular lensessense organsbusinessagreement030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Interchangeability among five devices that measure anterior eye distances.

2014

The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…

AdultMaleBiometrybusiness.industryAnterior ChamberMeasure (physics)Corneal TopographyReproducibility of ResultsEquipment DesignRefraction OcularRefractive ErrorsInterchangeabilityCorneaOphthalmologyYoung AdultOpticsOptometryMedicineHumansFemaleProspective StudiesbusinessOptometryFollow-Up StudiesClinicalexperimental optometry
researchProduct

Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions

2014

To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare.In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; BauschLomb], Acuvue Oasys for Presbyopia [AOP; JohnsonJohnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wear…

AdultMalegenetic structuresContact LensesComputer scienceCrossoverVisual AcuityGlareContrast SensitivityOpticsDouble-Blind MethodHumansLightingAnalysis of VarianceCross-Over Studiesbusiness.industryGlare (vision)PresbyopiaMiddle AgedCrossover studyeye diseasesOphthalmologyOptometryFemalesense organsbusinessEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

2014

Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…

Lenses IntraocularWavefrontPhysicsOptics and PhotonicsCorneal Wavefront Aberrationbusiness.industryZernike polynomialsAberrometryAstigmatismComa (optics)General MedicineModels TheoreticalOptical qualityOphthalmologyAlcon LaboratoriesSpherical aberrationsymbols.namesakeOpticsLens Implantation IntraocularIntraocular lensesAberrometrysymbolsHumansbusinessEuropean Journal of Ophthalmology
researchProduct

Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses

2021

Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…

Malemedicine.medical_specialtyPseudophakiaMesopic visionmedicine.medical_treatmentVisual AcuityUlls -- Acomodació i refraccióIntraocular lensRefraction OcularIntraocular lensesPupillaw.invention03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinelawOphthalmologymedicineHumansPostoperative PeriodProspective StudiesMathematicsAgedEye -- Accomodation and refractionVision BinocularIntraocular lensOpticsTrifocal diffractiveLents intraocularsHydrofilicRefractionSubjective refractionMultifocal Intraocular LensesSensory SystemsLens (optics)OphthalmologyRefractionAutorefractorPatient SatisfactionDifracció030221 ophthalmology & optometryFemale:Ciències de la visió [Àrees temàtiques de la UPC]Diffraction030217 neurology & neurosurgeryHydrofobicPhotopic visionFollow-Up Studies
researchProduct

Sensibilidad al contraste tras cirugía de cristalino transparente con lente intraocular multifocal asférica difractiva

2013

PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at t…

HiperopiaHyperopiaPhacoemulsificationVisual acuityMiopíaLens implantation intraocularImplantación de lentes intraocularesMyopiaAgudeza visualLens cristallineCristalinoFacoemulsificación
researchProduct

Impact of Lens Material on Objective Refraction in Eyes with Trifocal Diffractive Intraocular Lenses

2022

Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M (Zernike-coeffici…

researchProduct

Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

2018

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…

sense organsskin and connective tissue diseaseseye diseases
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

2018

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

genetic structureseye diseases
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator

2018

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

researchProduct