0000000000363184

AUTHOR

Beatriz Pardal-peláez

Influence of short implants geometry on primary stability.

Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…

research product

Implant loss and crestal bone loss in early loading versus delayed and immediate loading in edentulous mandibles. A systematic review and meta-analysis

Background Information about the risk of early loss and crestal bone loss of dental implants which have been loaded early is scant if compared with data available for those conventionally or immediately loaded. A meta-analysis of early loss and crestal bone loss in immediate or delayed loaded full mandibular denture retaining dental implants has been recently published. It is interesting to evaluate also the risks of early versus immediate and delayed loading in complete mandibular restorations. The purpose of this systematic review and meta-analysis was to study early (EL) versus immediate (IL) and delayed loading (DL) protocols in edentulous mandibles to determine whether differences exis…

research product

Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review

Background To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. Material and methods A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external connection implants were subjected to cyclic loads to determine the degree of loosening of the abutment screws after loading. Results The reviewed studies tested distinct implant connections (mostly externally hexed, and morse taper) subjected to diverse cycles (from 16667 to 1 million), with loads ran…

research product