0000000000379274

AUTHOR

Andrea Kronfeld

showing 14 related works from this author

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

Intrahematomal Ultrasound Enhances RtPA-Fibrinolysis in a Porcine Model of Intracerebral Hemorrhage

2021

Catheter-based ultrasound-thrombolysis has been successfully used in a small clinical trial in order to enhance recombinant tissue plasminogen activator (rtPA)-fibrinolysis, for the treatment of spontaneous intracerebral hemorrhages (ICHs). The aim of this study was to investigate the ultra-early effects of ultrasound on hematoma and the surrounding brain tissue in a porcine ICH-model. To achieve this, 21 pigs with a right frontal ICH were randomly assigned to four groups: (1) drainage (n = 3), (2) drainage + rtPA (n = 6), (3) drainage + ultrasound (n = 6), and (4) drainage + ultrasound + rtPA (n = 6). The hematoma volume assessment was performed using cranial MRI before and after the treat…

medicine.medical_treatmentlcsh:Medicine030204 cardiovascular system & hematologyArticle03 medical and health sciences0302 clinical medicineHematomaEdemartPA-fibrinolysisFibrinolysismedicineminimally invasive therapycardiovascular diseasesIntracerebral hemorrhagebusiness.industryUltrasoundlcsh:RGeneral Medicinemedicine.diseaseintracerebral hemorrhageCatheterImmunohistochemistrymedicine.symptombusinessNuclear medicinePerfusion030217 neurology & neurosurgeryultrasound-thrombolysisJournal of Clinical Medicine
researchProduct

Identification of High-Risk Atypical Meningiomas According to Semantic and Radiomic Features

2020

Up to 60% of atypical meningiomas (World Health Organization (WHO) grade II) reoccur within 5 years after resection. However, no clear radiological criteria exist to identify tumors with higher risk of relapse. In this study, we aimed to assess the association of certain radiomic and semantic features of atypical meningiomas in MRI with tumor recurrence. We identified patients operated on primary atypical meningiomas in our department from 2007 to 2017. An analysis of 13 quantitatively defined radiomic and 11 qualitatively defined semantic criteria was performed based on preoperative MRI scans. Imaging characteristics were assessed along with clinical and survival data. The analysis include…

Cancer Researchmedicine.medical_specialtyMultivariate analysisTumor resectionlcsh:RC254-282survivalArticleWorld healthResection03 medical and health sciences0302 clinical medicineatypical meningiomamedicineUnivariate analysisbusiness.industryHazard ratiopredictionOdds ratiolcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogensConfidence intervalOncologyradiomics030220 oncology & carcinogenesisRadiologybusiness030217 neurology & neurosurgeryCancers
researchProduct

Longitudinal imaging and evaluation of SAH-associated cerebral large artery vasospasm in mice using micro-CT and angiography

2019

Longitudinal in vivo imaging studies characterizing subarachnoid hemorrhage (SAH)-induced large artery vasospasm (LAV) in mice are lacking. We developed a SAH-scoring system to assess SAH severity in mice using micro CT and longitudinally analysed LAV by intravenous digital subtraction angiography (i.v. DSA). Thirty female C57Bl/6J-mice (7 sham, 23 SAH) were implanted with central venous ports for repetitive contrast agent administration. SAH was induced by filament perforation. LAV was assessed up to 14 days after induction of SAH by i.v. DSA. SAH-score and neuroscore showed a highly significant positive correlation (rsp = 0.803, p < 0.001). SAH-score and survival showed a negative sig…

medicine.medical_specialtySubarachnoid hemorrhageBiopsy030204 cardiovascular system & hematologySeverity of Illness IndexMice03 medical and health sciences0302 clinical medicineCerebral vasospasmIn vivomedicineAnimalsVasospasm Intracranialcardiovascular diseasesMicro ctmedicine.diagnostic_testbusiness.industryLarge arteryVasospasmOriginal ArticlesX-Ray MicrotomographyCerebral ArteriesSubarachnoid Hemorrhagemedicine.diseaseImmunohistochemistrynervous system diseasesCerebral AngiographyDisease Models AnimalNeurologyAngiographyFemaleNeurology (clinical)RadiologyCardiology and Cardiovascular MedicinebusinessBiomarkers030217 neurology & neurosurgeryPreclinical imagingJournal of Cerebral Blood Flow & Metabolism
researchProduct

JCB887052 Supplemetal Material - Supplemental material for Longitudinal imaging and evaluation of SAH-associated cerebral large artery vasospasm in m…

2019

Supplemental material, JCB887052 Supplemetal Material for Longitudinal imaging and evaluation of SAH-associated cerebral large artery vasospasm in mice using micro-CT and angiography by Vanessa Weyer, Máté E Maros, Andrea Kronfeld, Stefanie Kirschner, Christoph Groden, Clemens Sommer, Yasemin Tanyildizi, Martin Kramer and Marc A Brockmann in Journal of Cerebral Blood Flow & Metabolism

110320 Radiology and Organ ImagingFOS: Clinical medicineFOS: Biological sciencesMedicineCell Biology110305 Emergency Medicine110306 EndocrinologyBiochemistry69999 Biological Sciences not elsewhere classified110904 Neurology and Neuromuscular DiseasesNeuroscience
researchProduct

Cortex-wide BOLD fMRI activity reflects locally-recorded slow oscillation-associated calcium waves.

2017

When a person is in a deep non-dreaming sleep, neurons in their brain alternate slowly between periods of silence and periods of activity. This gives rise to low-frequency brain rhythms called slow waves, which are thought to help stabilize memories. Slow wave activity can be detected on multiple scales, from the pattern of electrical impulses sent by an individual neuron to the collective activity of the brain’s entire outer layer, the cortex. But does slow wave activity in an individual group of neurons in the cortex affect the activity of the rest of the brain? To find out, Schwalm, Schmid, Wachsmuth et al. took advantage of the fact that slow waves also occur under general anesthesia, a…

0301 basic medicinegenetic structuresQH301-705.5Scienceresting-state functional connectivityThalamusslow waves ; BOLD fMRI ; calcium recordingsBiologybehavioral disciplines and activitiesGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineRhythmslow wavesThalamusCortex (anatomy)medicineOscillation (cell signaling)Premovement neuronal activityAnimalsddc:610Calcium SignalingBOLD fMRIBiology (General)Functional MRICerebral CortexGeneral Immunology and MicrobiologyGeneral NeuroscienceQRGeneral MedicineHuman brainAnatomyMagnetic Resonance ImagingRatscalcium recordings030104 developmental biologymedicine.anatomical_structurenervous systemCerebral cortexMedicineRatNeuronInsightNeuroscience030217 neurology & neurosurgerypsychological phenomena and processesNeuroscienceeLife
researchProduct

Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal f…

2007

Purpose To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-TurboFLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. Materials and Methods In blood- and tissue-equivalent phantoms the relationship between signal intensity (SI) and contrast-medium concentration was evaluated for the three pulse sequences. In volunteers, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normalized upslopes (N…

AdultMaleImage qualityContrast MediaImage processingSensitivity and SpecificityMyocardial perfusion imagingHeart RateImage Processing Computer-AssistedImage noiseHumansMedicineRadiology Nuclear Medicine and imagingmedicine.diagnostic_testEcho-Planar ImagingPhantoms ImagingPulse (signal processing)business.industryMyocardiumReproducibility of ResultsLinearityMagnetic resonance imagingMagnetic Resonance ImagingPerfusionLinear rangeFemalebusinessNuclear medicineBiomedical engineeringJournal of Magnetic Resonance Imaging
researchProduct

Pharmacokinetics of the cannabinoid receptor ligand [18 F]MK-9470 in the rat brain - Evaluation of models using microPET

2018

PURPOSE The positron emission tomography ligand [18 F]MK-9470 is an inverse agonist that binds reversibly and with high affinity to the cannabinoid type 1 receptor. Due to its slow brain kinetics, care is required in the definition of its dissociation rates from the receptor. The goal of this study was to investigate pharmacokinetic analysis methods using an arterial input function. METHODS Five Sprague-Dawley rats received injections of 13 to 25 MBq of [18 F]MK-9470 and were scanned over a period of 90 min. Arterial blood samples were collected throughout the scan. Data were analyzed using four different compartmental models: a reversible one-tissue model, reversible two tissue models with…

Volume of distributionmedicine.diagnostic_testGeneral MedicineMK-9470030218 nuclear medicine & medical imaging03 medical and health scienceschemistry.chemical_compound0302 clinical medicineNuclear magnetic resonanceStandard errorchemistryGoodness of fitPharmacokineticsPositron emission tomographymedicineInverse agonistAkaike information criterion030217 neurology & neurosurgeryMedical Physics
researchProduct

Evaluation of MRI and cannabinoid type 1 receptor PET templates constructed using DARTEL for spatial normalization of rat brains

2015

Purpose: Image registration is one prerequisite for the analysis of brain regions in magnetic-resonance-imaging (MRI) or positron-emission-tomography (PET) studies. Diffeomorphic anatomical registration through exponentiated Lie algebra (DARTEL) is a nonlinear, diffeomorphic algorithm for image registration and construction of image templates. The goal of this small animal study was (1) the evaluation of a MRI and calculation of several cannabinoid type 1 (CB1) receptor PET templates constructed using DARTEL and (2) the analysis of the image registration accuracy of MR and PET images to their DARTEL templates with reference to analytical and iterative PET reconstruction algorithms. Methods:…

medicine.diagnostic_testComputer sciencebusiness.industryImage registrationMagnetic resonance imagingPattern recognitionImage processingGeneral MedicineIterative reconstructionScintigraphyRegularization (mathematics)White mattermedicine.anatomical_structurePositron emission tomographyOrdered subset expectation maximizationSpatial normalizationmedicineMaximum a posteriori estimationTomographyArtificial intelligencebusinessNuclear medicineMedical Physics
researchProduct

Modeling Vestibular Compensation: Neural Plasticity Upon Thalamic Lesion.

2020

The present study in rats was conducted to identify brain regions affected by the interruption of vestibular transmission and to explore selected aspects of their functional connections. We analyzed, by positron emission tomography (PET), the regional cerebral glucose metabolism (rCGM) of cortical, and subcortical cerebral regions processing vestibular signals after an experimental lesion of the left laterodorsal thalamic nucleus, a relay station for vestibular input en route to the cortical circuitry. PET scans upon galvanic vestibular stimulation (GVS) were conducted in each animal prior to lesion and at post-lesion days (PLD) 1, 3, 7, and 20, and voxel-wise statistical analysis of rCGM a…

Thalamusneuronal tracingSensory systemSomatosensory systemInsular cortexlcsh:RC346-429Lesionlesion03 medical and health sciences0302 clinical medicinethalamusMedicinePET-imagingimmunofluorescenceGalvanic vestibular stimulationlcsh:Neurology. Diseases of the nervous system030304 developmental biologyOriginal ResearchVestibular system0303 health sciencesbusiness.industrymedicine.anatomical_structureNeurologyCerebral cortexcerebral cortexNeurology (clinical)medicine.symptombusinessNeuroscience030217 neurology & neurosurgeryFrontiers in neurology
researchProduct

Resection of C6 gliomas in rats with the aid of the waterjet technique

2016

While clinically the safety and efficacy of waterjet resection of brain tumors have been shown, evidence that waterjet dissection improves tumor resection radicality in comparison with conventional techniques is still missing. In the present study, resection radicality and tumor-free long-term survival of both techniques were evaluated in a C6-glioma model.Fifty-thousand C6-glioma cells were stereotactically transplanted in the left frontal lobe of 100 male Sprague-Dawley rats. After MRI-scanning for evaluation of tumor extension, microsurgical tumor resection was performed with conventional techniques (n=50) or with the waterjet dissector at pressures of 6bar (n=50). Twenty-five animals of…

MaleSurgical resultsmedicine.medical_specialtyTumor resectionLeft frontal lobeDirect transferNeurosurgical ProceduresResectionRats Sprague-Dawley03 medical and health sciences0302 clinical medicineAnimalsMedicinePostoperative outcomeConventional techniqueBrain Neoplasmsbusiness.industryGliomaGeneral MedicineRatsSurgeryDisease Models AnimalDissection030220 oncology & carcinogenesisSurgeryNeurology (clinical)business030217 neurology & neurosurgeryClinical Neurology and Neurosurgery
researchProduct

Towards a glioma model for surgical technique evaluation in the rat.

2013

Evaluation of new surgical techniques in animal models is frequently challenging. This article describes the pitfalls, peculiarities and the final best applicable model for evaluating surgical techniques for glioma resection.The C6 glioma cell line and the Sprague-Dawley rat strain were selected. Fifty-thousand glioma cells were stereotactically transplanted in the left hemisphere of 137 male adult rats. Evaluation of solid tumour formation, tumour growth and scheduling of surgical resection was performed by MR scanning at 1, 2, and 4 weeks after transplantation and 3 and 6 months after tumour resection. Microsurgical tumour resection was performed with conventional techniques or with the w…

Malemedicine.medical_specialtyMicrosurgeryCell Transplantationmedicine.medical_treatmentTumor resectionNeurosurgical ProceduresResectionRats Sprague-DawleyGliomaCell Line TumormedicineTumor Cells CulturedAnimalsSolid tumourmedicine.diagnostic_testbusiness.industryBrain NeoplasmsMagnetic resonance imagingGeneral MedicineGliomaMicrosurgerymedicine.diseaseMagnetic Resonance ImagingSurgeryRatsTransplantationDisease Models AnimalSurgeryNeurology (clinical)businessComplicationBritish journal of neurosurgery
researchProduct

Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data.

2010

Objective Partial volume effects caused by limited spatial resolution of conventional positron emission tomography (PET) scanners result in an underestimation of the activity concentration in small tumours. The aim of the study was to evaluate the feasibility of small animal tumour imaging with the clinical PET scanner ECAT EXACT after partial volume correction based on MRI calculations. The same tumour model was examined additionally with the small animal PET system, microPET focus 120. Methods Before the ECAT EXACT studies recovery coefficients for different sphere volumes were generated with phantom experiments. For the following in-vivo study DS-sarcoma cells were implanted on both hind…

MaleScannerFocus (geometry)Partial volumeImaging phantomRats Sprague-DawleySmall animalNeoplasmsmedicineAnimalsRadiology Nuclear Medicine and imagingGamma countermedicine.diagnostic_testbusiness.industryPhantoms ImagingMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingRatsTumor BurdenPositron emission tomographyPositron-Emission TomographyLinear ModelsFeasibility StudiesNuclear medicinebusinessArtifactsNuclear medicine communications
researchProduct

Author response: Cortex-wide BOLD fMRI activity reflects locally-recorded slow oscillation-associated calcium waves

2017

0301 basic medicinePhysics03 medical and health sciences030104 developmental biologymedicine.anatomical_structureCortex (anatomy)Oscillation (cell signaling)medicineBold fmriCalcium WavesNeuroscience
researchProduct