Extensive Assessment of Blood Glucose Monitoring During Postprandial Period and Its Impact on Closed-Loop Performance.
[EN] Background: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. Methods: We performed an extensive analysis of sensor¿s performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. Results: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2…
Estudio de receptor anómalo suprarrenal en sujetos con síndrome de Cushing ACTH-independiente e hiperplasia nodular suprarrenal
Resumen Introduccion El sindrome de Cushing ACTH-independiente (SCAI) supone el 15-20% de los casos de sindrome de Cushing, de los cuales Material y metodos Estudio descriptivo multicentrico de una serie de 15 casos de SCAI con hiperplasia nodular suprarrenal (periodo de estudio: 2002-2016). En ellos se hizo el despistaje de receptor anomalo, mediante pruebas de estimulacion, considerando patologico un aumento de cortisol plasmatico ≥ del 25% respecto al valor basal. Resultados De los 15 casos, 13 fueron mujeres, con una edad media al diagnostico de 56,8 anos. En 12 de los 15 casos estudiados se detecto positividad de las pruebas de estimulacion. De ellos, fueron positivos para comida de pr…
A Multiple Local Models Approach to Accuracy Improvement in Continuous Glucose Monitoring
Continuous glucose monitoring (CGM) devices estimate plasma glucose (PG) from measurements in compartments alternative to blood. The accuracy of currently available CGM is yet unsatisfactory and may depend on the implemented calibration algorithms, which do not compensate adequately for the differences of glucose dynamics between the compartments. Here we propose and validate an innovative calibration algorithm for the improvement of CGM performance.CGM data from GlucoDay(®) (A. Menarini, Florence, Italy) and paired reference PG have been obtained from eight subjects without diabetes during eu-, hypo-, and hyperglycemic hyperinsulinemic clamps. A calibration algorithm based on a dynamic glo…
Plasma Insulin Levels and Hypoglycemia Affect Subcutaneous Interstitial Glucose Concentration
[EN] Background: Continuous glucose monitoring (CGM) accuracy during hypoglycemia is suboptimal. This might be partly explained by insulin or hypoglycemia-induced changes in the plasma interstitial subcutaneous (SC) fluid glucose gradient. The aim of the present study was to assess the role of plasma insulin (PI) and hypoglycemia itself in the plasma and interstitial SC fluid glucose concentration in patients with type 1 diabetes mellitus. Methods: Eleven subjects with type 1 diabetes (age 36.59.1 years, HbA(1c) 7.90.4% [62.8 +/- 2.02mmol/mol]; mean +/- standard deviation) were evaluated under hyperinsulinemic euglycemia and hypoglycemia. Each subject underwent two randomized crossover clam…
Real-time estimation of plasma insulin concentration from continuous glucose monitor measurements
Continuous glucose monitors can measure interstitial glucose concentration in real time for closed-loop glucose control systems, known as artificial pancreas. These control systems use an insulin feedback to maintain plasma glucose concentration within a narrow and safe range, and thus to avoid health complications. As it is not possible to measure plasma insulin concentration in real time, insulin models have been used in literature to estimate them. Nevertheless, the significant interand intra-patient variability of insulin absorption jeopardizes the accuracy of these estimations. In order to reduce these limitations, our objective is to perform a real-time estimation of plasma insulin co…
Study of abnormal adrenal receptors in subjects with ACTH-independent Cushing's syndrome and nodular adrenal hyperplasia
ACTH-independent Cushing's Syndrome (AICS) accounts for 15-20% of cases of Cushing's syndrome, with1% due to abnormal receptors. Our aim is to study the presence of abnormal receptors in subjects diagnosed with AICS with nodular adrenal hyperplasia in a 14-year period (2002-2016), as well as its clinical-biological and evolutive characteristics.A multicentre descriptive study of a 15-case series of AICS with nodular adrenal hyperplasia (study period: 2002-2016). In these cases, abnormal receptor screening was performed by means of stimulation tests, with a plasma cortisol increase of ≥ 25% from baseline being considered pathologic.Of the 15 cases, 13 were female, with a mean age at diagnosi…