0000000000441310

AUTHOR

K. Bailey

showing 22 related works from this author

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

2018

The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgro…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsNuclear physicsFOS: Physical scienceschemistry.chemical_elementRadonElectron01 natural sciencesAtomicMathematical SciencesHigh Energy Physics - Experimentlaw.inventionIonNuclear physicsHigh Energy Physics - Experiment (hep-ex)XenonParticle and Plasma PhysicslawDouble beta decay0103 physical sciencesDark Matter and Double Beta Decay (experiments)lcsh:Nuclear and particle physics. Atomic energy. RadioactivityNuclearNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentMathematical PhysicsPhysicsQuantum PhysicsTime projection chamber010308 nuclear & particles physicsDetectorMolecularInstrumentation and Detectors (physics.ins-det)Double beta decayNuclear & Particles PhysicsCathodeDoble desintegració betachemistryPhysical Scienceslcsh:QC770-798Física nuclear
researchProduct

The Next White (NEW) detector

2018

[EN] Conceived to host 5 kg of xenón at a pressure of 15 bar in the ¿ducial volume,the NEXTWhite (NEW)apparatus is currently the largest high pressure xenon gas TPC using electroluminescent ampli¿cation in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for ßß0¿ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas puri…

Physics - Instrumentation and DetectorsXenon010308 nuclear & particles physicsEuropean researchLibrary scienceFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)7. Clean energy01 natural sciencesHigh-pressure xenon chambersTECNOLOGIA ELECTRONICATime Projection Chamber (TPC)Political science0103 physical sciencesmedia_common.cataloged_instanceEuropean unionNeutrinoless double beta decay010306 general physicsInstrumentationMathematical Physicsmedia_commonNEXT-100 experiment
researchProduct

Mitigation of backgrounds from cosmogenic 137 Xe in xenon gas experiments using 3 He neutron capture

2020

[EN] Xe-136 is used as the target medium for many experiments searching for 0 nu beta beta. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of Xe-137 created by the capture of neutrons on Xe-136. This isotope decays via beta decay with a half-life of 3.8 min and a Q(beta) of similar to 4.16 MeV. This work proposes and explores the concept of adding a small percentage of He-3 to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we f…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsScintillation and light emission processesGas and liquid scintillatorsFOS: Physical scienceschemistry.chemical_element01 natural sciences7. Clean energyHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICANuclear physicsGaseous detectorsSolidHigh Energy Physics - Experiment (hep-ex)XenonDouble beta decay0103 physical sciencesIsotopes of xenonSpallationNeutron010306 general physicsPhysics010308 nuclear & particles physicsFísicaInstrumentation and Detectors (physics.ins-det)Beta DecayNeutron temperatureNeutron capturechemistryScintillatorsRadioactive decayJournal of Physics G: Nuclear and Particle Physics
researchProduct

Ba$^{2+}$ ion trapping by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector

2022

If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($\beta\beta 0\nu$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay ${}^{136}\mathrm{Xe} \rightarrow {}^{136}$Ba$^{+2}+ 2 e + (2 \nu)$ in a high pressure gas experiment, could lead to a virtually background free experiment. To identify these \Bapp, chemical sensors are being explored as a key tool by the NEXT collaboration . Although used in many fields, the application of such chemose…

Chemical Physics (physics.chem-ph)High Energy Physics - Experiment (hep-ex)Condensed Matter - Materials SciencePhysics - Chemical PhysicsMaterials Science (cond-mat.mtrl-sci)FOS: Physical sciencesHigh Energy Physics - Experiment
researchProduct

High Voltage Insulation and Gas Absorption of Polymers in High Pressure Argon and Xenon Gases

2018

High pressure gas time projection chambers (HPGTPCs) are made with a variety of materials, many of which have not been well characterized in high pressure noble gas environments. As HPGTPCs are scaled up in size toward ton-scale detectors, assemblies become larger and more complex, creating a need for detailed understanding of how structural supports and high voltage insulators behave. This includes the identification of materials with predictable mechanical properties and without surface charge accumulation that may lead to field deformation or sparking. This paper explores the mechanical and electrical effects of high pressure gas environments on insulating polymers PTFE, HDPE, PEEK, POM …

Materials scienceArgonPhysics - Instrumentation and Detectors010308 nuclear & particles physicsFOS: Physical scienceschemistry.chemical_elementNoble gasHigh voltageInstrumentation and Detectors (physics.ins-det)01 natural sciencesCharacterization (materials science)High Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)Xenonchemistry0103 physical sciencesPeekSurface chargeNuclear Experiment (nucl-ex)Absorption (chemistry)Composite material010306 general physicsInstrumentationNuclear ExperimentMathematical Physics
researchProduct

Counting individual 41Ca atoms with a magneto-optical trap

2003

Atom Trap Trace Analysis (ATTA), a novel method based upon laser trapping and cooling, is used to count individual atoms of 41Ca present in biomedical samples with isotopic abundance levels between 10^-8 and 10^-10. ATTA is calibrated against Resonance Ionization Mass Spectrometry, demonstrating a good agreement between the two methods. The present ATTA system has a counting efficiency of 2x10^-7. Within one hour of observation time, its 3-sigma detection limit on the isotopic abundance of 41Ca reaches 4.5x10^-10.

Atomic Physics (physics.atom-ph)Biological Physics (physics.bio-ph)FOS: Physical sciencesPhysics - Biological PhysicsPhysics - Atomic Physics
researchProduct

Demonstration of the event identification capabilities of the NEXT-White detector

2019

[EN] In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat ± 0.3 sys% for a background acceptance of 20.6 ± …

Nuclear and High Energy PhysicsPhysical measurementsPhysics - Instrumentation and DetectorsMonte Carlo methodExtrapolationFísica -- MesuramentsFOS: Physical sciences7. Clean energy01 natural sciencesAtomicMathematical SciencesHigh Energy Physics - ExperimentNuclear physicsTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)Particle and Plasma PhysicsDouble beta decay0103 physical sciencesDark Matter and Double Beta Decay (experiments)Calibrationlcsh:Nuclear and particle physics. Atomic energy. RadioactivityNuclearCalibratge010306 general physicsNuclear ExperimentMathematical PhysicsPhysicsQuantum Physics010308 nuclear & particles physicsDetectorMolecularDetectorsInstrumentation and Detectors (physics.ins-det)Nuclear & Particles PhysicsCalibrationPhysical Scienceslcsh:QC770-798High Energy Physics::ExperimentSensitivity (electronics)Event (particle physics)Energy (signal processing)
researchProduct

Radiogenic backgrounds in the NEXT double beta decay experiment

2019

[EN] Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterraneo de Canfranc with xenon depleted in Xe-136 are analyzed to derive a total background rate of (0.84 +/- 0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEX…

Nuclear and High Energy PhysicsPhysical measurementsPhysics - Instrumentation and DetectorsDark Matter and Double Beta DecayDark matterFísica -- Mesuramentschemistry.chemical_elementFOS: Physical sciencesRadon7. Clean energy01 natural sciencesAtomicMathematical SciencesHigh Energy Physics - ExperimentNuclear physicsTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)XenonParticle and Plasma PhysicsDouble beta decayDark matter and double beta decay (experiments)0103 physical sciencesDark Matter and Double Beta Decay (experiments)Dark Matterlcsh:Nuclear and particle physics. Atomic energy. RadioactivityNuclear010306 general physicsDouble Beta DecayNatural radioactivityMathematical PhysicsPhysicsQuantum PhysicsRadiogenic nuclide010308 nuclear & particles physicsDetectorMolecularDetectorsInstrumentation and Detectors (physics.ins-det)Nuclear & Particles PhysicschemistryPhysical Scienceslcsh:QC770-798Event (particle physics)
researchProduct

Sensitivity of a tonne-scale NEXT detector for neutrinoless double beta decay searches

2020

The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of neutrinoless double-beta decay decay better than 1E27 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the in…

Physics - Instrumentation and DetectorsFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Nuclear Experiment (nucl-ex)Nuclear Experiment
researchProduct

Energy calibration of the NEXT-White detector with 1% resolution near Q ββ of 136Xe

2019

Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($\beta\beta0\nu$) require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for $\beta\beta0\nu$ searches.

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPhysical measurementsPhysics::Instrumentation and DetectorsDark Matter and Double Beta DecayFísica -- Mesuramentschemistry.chemical_elementBioengineeringAtomic01 natural sciencesMathematical SciencesNuclear physicsParticle and Plasma PhysicsXenonAffordable and Clean Energy0103 physical sciencesDark Matter and Double Beta Decay (experiments)CalibrationNuclearlcsh:Nuclear and particle physics. Atomic energy. RadioactivityCalibratge010306 general physicsMathematical PhysicsPhysicsQuantum Physics010308 nuclear & particles physicsDetectorResolution (electron density)MolecularDetectorsNuclear & Particles PhysicsFull width at half maximumchemistryBeta (plasma physics)Physical SciencesCalibrationlcsh:QC770-798High Energy Physics::ExperimentNeutrinoEnergy (signal processing)
researchProduct

Electron drift and longitudinal diffusion in high pressure xenon-helium gas mixtures

2019

We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all $E/P$, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient than theoretical predictions is found at low $E/P$ in pure xenon, below the range of reduced fields usually probed by TPC experiments. A similar effect is observed in xenon-helium gas mixtures at somewhat larger $E/P$. Drift velocities in xenon-helium mixtures are found to be theoretically well pred…

Physics - Instrumentation and DetectorsMaterials scienceDrift velocityPhysics::Instrumentation and DetectorsExtrapolationFOS: Physical scienceschemistry.chemical_elementElectron01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineXenonElectric field0103 physical sciencesPhysics::Atomic and Molecular ClustersNuclear Experiment (nucl-ex)Diffusion (business)Nuclear ExperimentInstrumentationMathematical PhysicsHelium010308 nuclear & particles physicsInstrumentation and Detectors (physics.ins-det)chemistryAtomic physicsBar (unit)
researchProduct

Electron drift properties in high pressure gaseous xenon

2018

[EN] Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and di¿usion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent ampli¿cation, a 1:2 scale model of the future NEXT-100detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December2016. The drift parameters have been measured using 83mKr for a range of reduced drift ¿elds at two di¿erent pressure regimes, namely 7.2 bar and 9.1 bar. Theresults have been comp…

Physics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsLibrary scienceFOS: Physical sciencesCharge transport01 natural sciences7. Clean energyElectron driftHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)Political science0103 physical sciencesmedia_common.cataloged_instanceEuropean unionNuclear Experiment (nucl-ex)010306 general physicsInstrumentationNuclear ExperimentMathematical Physicsmedia_commonCharge transport and multiplication in gas010308 nuclear & particles physicsEuropean researchMultiplication and electroluminescence in rare gases and liquidsInstrumentation and Detectors (physics.ins-det)Double-beta decay detectorsGaseous imaging and tracking detectorsHigh pressureHigh Energy Physics::ExperimentJournal of Instrumentation
researchProduct

Early outcomes and complications following cardiac surgery in patients testing positive for coronavirus disease 2019: An international cohort study

2021

The outbreak of severe acute respiratory syndromecoronavirus-2, the cause of coronavirus disease 2019 (COVID-19) in December 2019 represented a global emergency accounting for more than 2.5 million deaths worldwide.1 It has had an unprecedented influence on cardiac surgery internationally, resulting in cautious delivery of surgery and restructuring of services.2 Understanding the influence of COVID-19 on patients after cardiac surgery is based on assumptions from other surgical specialties and single-center studies. The COVIDSurg Collaborative conducted a multicenter cohort study, including 1128 patients, across 235 hospitals, from 24 countries demonstrating perioperative COVID-19 infection…

Pulmonary and Respiratory MedicineMale2019-20 coronavirus outbreakmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)complication.ArticleNOCohort Studiesoutcomes; complications; following cardiac surgery; coronavirus disease 2019Postoperative ComplicationsCardiovascular Diseases; Cohort Studies; Female; Humans; Male; Middle Aged; SARS-CoV-2; COVID-19; Cardiac Surgical Procedures; Postoperative ComplicationsInternal medicineCardiovascular DiseasemedicineCardiac Surgical ProcedureHumansIn patientCardiac Surgical ProceduresLS7_4business.industrySARS-CoV-2COVID-19Middle AgedCardiac surgeryCardiovascular DiseasesoutcomeSurgeryFemaleCohort StudieCardiology and Cardiovascular Medicinebusinesscardiac surgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyCohort studyHuman
researchProduct

Neutral Bremsstrahlung emission in xenon unveiled

2022

We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that has been postulated to exist in xenon that has been largely overlooked. For photon emission below 1000 nm, the NBrS yield increases from about 10$^{-2}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at pressure-reduced electric field values of 50 V cm$^{-1}$ bar$^{-1}$ to above 3$\times$10$^{-1}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at 500 V cm$^{-1}$ bar$^{-1}$. Above 1.5 kV cm$^{-1}$ bar$^{-1}$, values that …

Physics - Instrumentation and DetectorsAtomic Physics (physics.atom-ph)General Physics and AstronomyFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Astrophysics - Instrumentation and Methods for AstrophysicsInstrumentation and Methods for Astrophysics (astro-ph.IM)Physics - Atomic Physics
researchProduct

The dynamics of ions on phased radio-frequency carpets in high pressure gases and application for barium tagging in xenon gas time projection chambers

2022

NEXT Collaboration: et al.

Nuclear and High Energy PhysicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Energy calibration of the NEXT-White detector with 1% resolution near Qßß of 136Xe

2019

Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ßß0¿), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ßß0¿ searches. [Figure not available: see fulltext.

researchProduct

Calibration of the NEXT-White detector using 83m Kr decays

2018

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterr'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83mKr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for …

PhysicsTime projection chamber010308 nuclear & particles physicsKryptonDetectorSolid anglechemistry.chemical_element01 natural sciencesNuclear physicsFull width at half maximumXenonchemistryDouble beta decay0103 physical sciencesCalibration010306 general physicsInstrumentationMathematical PhysicsJournal of Instrumentation
researchProduct

Machine learning risk prediction of mortality for patients undergoing surgery with perioperative SARS-CoV-2: the COVIDSurg mortality score

2021

The British journal of surgery 108(11), 1274-1292 (2021). doi:10.1093/bjs/znab183

Cuidado perioperatorioAcademicSubjects/MED00910Settore MED/18 - CHIRURGIA GENERALEMedizinpulmonary complicationspreoperative screeningDatasets as TopicSurgical Procedures Operative/mortality030230 surgeryperioperative care ; surgical procedures ; operative mortality ; machine learning ; sars-cov-2Medical and Health SciencesProcediments quirúrgicsCohort StudiesMachine LearningTumours of the digestive tract Radboud Institute for Health Sciences [Radboudumc 14]0302 clinical medicineModelsProcedimientos quirúrgicosMedicine and Health SciencesCOVIDSurg Collaborative Co-authorsMedicine030212 general & internal medicineskin and connective tissue diseasesRapid Research Communication11 Medical and Health SciencesOperative/mortalitySARS-CoV-19COVID-19/mortalityStatisticalCOVID-19/mortality; Cohort Studies; Datasets as Topic; Humans; Machine Learning; Models Statistical; Risk Assessment; SARS-CoV-2; Surgical Procedures Operative/mortalityCOVID-19; Cohort Studies; Datasets as Topic; Humans; Machine Learning; SARS-CoV-2; Surgical Procedures Operative; Models Statistical; Risk AssessmentAprendizaje automáticoOperativeSurgical Procedures OperativeoutcomeOperativo[SDV.IB]Life Sciences [q-bio]/BioengineeringPatient SafetyAcademicSubjects/MED000106.4 SurgeryLife Sciences & BiomedicineHuman61medicine.medical_specialty616.9Coronavirus disease 2019 (COVID-19)Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-.Risk AssessmentNOCOVIDSurg CollaborativeVaccine Related03 medical and health sciencesClinical ResearchBiodefenseCures perioperatòriesAprenentatge automàticMortalitatHumansOperatiusLS7_4Surgical ProceduresScience & TechnologyModels Statisticalbusiness.industrySARS-CoV-2SARS-CoV-2 infectionKirurgiPreventionnot indicatedcovid 19fungiEvaluation of treatments and therapeutic interventionsCOVID-19Perioperativecovid 19; pulmonary complications; postoperative mortality risk; SARS-CoV-2 infection; preoperative screening; vaccinationvaccinationmortalityGood Health and Well BeingMortalidadEmergency medicineSurgeryHuman medicineCohort Studiebusinesspostoperative mortality riskPerioperative care
researchProduct

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

2020

[EN] High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have m…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsFOS: Physical sciencesLibrary scienceApplied Physics (physics.app-ph)7. Clean energy01 natural sciencesAtomicPartícules (Física nuclear)TECNOLOGIA ELECTRONICAParticle and Plasma PhysicsDark Matter and Double Beta Decay (experiments)0103 physical sciencesmedia_common.cataloged_instancelcsh:Nuclear and particle physics. Atomic energy. RadioactivityNuclearEuropean union010306 general physicsMathematical Physicsmedia_commonParticles (Nuclear physics)PhysicsQuantum PhysicsPhotons010308 nuclear & particles physicsPreventionRare event detectionEuropean researchMolecularInstrumentation and Detectors (physics.ins-det)Physics - Applied PhysicsParticle correlations and fluctuationsNuclear & Particles PhysicsDouble beta decayFotonsDoble desintegració betaRare decayElectroluminescence13. Climate actionPhoton productionlcsh:QC770-798ElectroluminescènciaNational laboratoryJournal of High Energy Physics
researchProduct

Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays

2018

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterr\'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellen…

High Energy Physics - Experiment (hep-ex)Physics - Instrumentation and DetectorsFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)High Energy Physics - Experiment
researchProduct

Mitigation of backgrounds from cosmogenic 137Xe in xenon gas experiments using 3He neutron capture

2021

136Xe is used as the target medium for many experiments searching for 0¿ßß. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137Xe created by the capture of neutrons on 136Xe. This isotope decays via beta decay with a half-life of 3.8 min and a Q ß of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137Xe …

researchProduct

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

2021

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance i…

researchProduct