0000000000476658

AUTHOR

C. Johnston

showing 3 related works from this author

Hypernuclear Spectroscopy at JLab Hall C

2010

Abstract Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e'K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e'K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7 Λ He and 28 Λ Al together with that of 12 Λ B that achieved resolution better than 500 keV(FWHM) were obtained. The third generation…

Nuclear physicsPhysicsNuclear and High Energy PhysicsParticle physicsFull width at half maximumLuminosity (scattering theory)Electron spectrometerSpectrometerResolution (electron density)Calibrationhypernuclear; electroproduction; kaon spectrometer; electron spectrometerSpectroscopySpectral lineNuclear Physics A
researchProduct

Mosquito Magnet ® traps as a potential means of monitoring blackflies of medical and veterinary importance

2021

Mosquito Magnet® traps, deployed in widespread parts of England as part of nationwide mosquito surveillance projects, also caught blackflies. As many as 1242 blackflies were caught in a trapping session lasting 4 days. Principal among the species caught were Simulium equinum, Simulium lineatum and Simulium ornatum s.l. As S. ornatum s.l. is a vector that transmits Onchocerca linealis to cattle and S. equinum is responsible for dermatitis ('sweet itch') in cattle and horses, it is suggested that Mosquito Magnet® traps could be used to monitor and partially control these pests, as well as nuisance anthropophilic blackflies such as Simulium posticatum that can cause simuliidosis in southern En…

0301 basic medicineVeterinary medicineS1Simulium posticatum030231 tropical medicineCattle DiseasesMosquito VectorsDisease VectorsSimulium lineatumBiologyOnchocerciasisSimulium ornatumSimuliidosisPlagues Control03 medical and health sciences0302 clinical medicineparasitic diseasesAnimalsSimuliidaeHorsesVeterinàriaEcology Evolution Behavior and SystematicsGeneral VeterinaryfungiSimulium equinum030108 mycology & parasitologySweet itchCulicidaeInsect ScienceVector (epidemiology)CattleHorse DiseasesParasitologyOnchocercaNuisanceMedical and Veterinary Entomology
researchProduct

Search forBs0→μ+μ−andB0→μ+μ−Decays with CDF II

2011

A search has been performed for B{sub s}{sup 0} {yields} {mu}{sup +}{mu}{sup -} and B{sup 0} {yields} {mu}{sup +}{mu}{sup -} decays using 7 fb{sup -1} of integrated luminosity collected by the CDF II detector at the Fermilab Tevatron collider. The observed number of B{sup 0} candidates is consistent with background-only expectations and yields an upper limit on the branching fraction of {Beta}(B{sup 0} {yields} {mu}{sup +}{mu}{sup -}) < 6.0 x 10{sup -9} at 95% confidence level. We observe an excess of B{sub s}{sup 0} candidates. The probability that the background processes alone could produce such an excess or larger is 0.27%. The probability that the combination of background and the expe…

Flight directionNuclear and High Energy PhysicsParticle physicsMesonTevatronGeneral Physics and Astronomy01 natural sciences7. Clean energyLuminosityStandard Modellaw.inventionNuclear physicsParticle decaychemistry.chemical_compoundlawTheoryofComputation_ANALYSISOFALGORITHMSANDPROBLEMCOMPLEXITY0103 physical sciencesInvariant massLimit (mathematics)FermilabCollider010306 general physicsPhysicsMuon010308 nuclear & particles physicsBranching fractionSupersymmetryD0 experimentIMesCrystallographychemistryDecay lengthHigh Energy Physics::ExperimentLeptonPhysical Review Letters
researchProduct