Improved sample preparation for the testosterone hydroxylation assay using disposable extraction columns
The preparation of samples for injection into a high-performance liquid chromatograph from assay mixtures for the determination of cytochrome P-450-dependent testosterone hydroxylation has been substantially facilitated. By replacing the multiple cumbersome extraction steps of the conventional method with a single column extraction the time for sample preparation was reduced from hours to minutes. The new procedure also yields better recoveries for most of the testosterone metabolites than the original protocol. The use of extraction columns for sample preparation allows the simultaneous treatment of a large number of samples or even the automation of the whole assay procedure. The modified…