0000000000536192
AUTHOR
A Weber
Effect of Intraoperative High Positive End-Expiratory Pressure (PEEP) with Recruitment Maneuvers vs Low PEEP on Postoperative Pulmonary Complications in Obese Patients: A Randomized Clinical Trial
Importance: An intraoperative higher level of positive end-expiratory positive pressure (PEEP) with alveolar recruitment maneuvers improves respiratory function in obese patients undergoing surgery, but the effect on clinical outcomes is uncertain. Objective: To determine whether a higher level of PEEP with alveolar recruitment maneuvers decreases postoperative pulmonary complications in obese patients undergoing surgery compared with a lower level of PEEP. Design, Setting, and Participants: Randomized clinical trial of 2013 adults with body mass indices of 35 or greater and substantial risk for postoperative pulmonary complications who were undergoing noncardiac, nonneurological surgery un…
International Scoping Study (ISS) for a future neutrino factory and Super-Beam facility. Detectors and flux instrumentation for future neutrino facilities
Technical report by The ISS Detector Working Group; This report summarises the conclusions from the detector group of the International Scoping Study of a future Neutrino Factory and Super-Beam neutrino facility. The baseline detector options for each possible neutrino beam are defined as follows: 1. A very massive (Megaton) water Cherenkov detector is the baseline option for a sub-GeV Beta Beam and Super Beam facility. 2. There are a number of possibilities for either a Beta Beam or Super Beam (SB) medium energy facility between 1-5 GeV. These include a totally active scintillating detector (TASD), a liquid argon TPC or a water Cherenkov detector. 3. A 100 kton magnetized iron neutrino det…
Linkage disequilibrium screening for multiple sclerosis implicates JAG1 and POU2AF1 as susceptibility genes in Europeans.
By combining all the data available from the Genetic Analysis of Multiple sclerosis in EuropeanS (GAMES) project, we have been able to identify 17 microsatellite markers showing consistent evidence for apparent association. As might be expected five of these markers map within the Major Histocompatibility Complex (MHC) and are in LD with HLA-DRB1. Individual genotyping of the 12 non-MHC markers confirmed association for three of them — D11S1986, D19S552 and D20S894. Association mapping across the candidate genes implicated by these markers in 937 UK trio families revealed modestly associated haplotypes in JAG1 (p=0.019) on chromosome 20p12.2 and POU2AF1 (p=0.003) on chromosome 11q23.1.
Measurement of the intrinsic electron neutrino component in the T2K neutrino beam with the ND280 detector
The T2K experiment has reported the first observation of the appearance of electron neutrinos in a muon neutrino beam. The main and irreducible background to the appearance signal comes from the presence in the neutrino beam of a small intrinsic component of electron neutrinos originating from muon and kaon decays. In T2K, this component is expected to represent 1.2% of the total neutrino flux. A measurement of this component using the near detector (ND280), located 280 m from the target, is presented. The charged current interactions of electron neutrinos are selected by combining the particle identification capabilities of both the time projection chambers and electromagnetic calorimeters…
Measurement of Neutrino Oscillation Parameters from Muon Neutrino Disappearance with an Off-Axis Beam
The T2K Collaboration reports a precision measurement of muon neutrino disappearance with an off-axis neutrino beam with a peak energy of 0.6 GeV. Near detector measurements are used to constrain the neutrino flux and cross section parameters. The Super-Kamiokande far detector, which is 295 km downstream of the neutrino production target, collected data corresponding to 3.01 x 10(20) protons on target. In the absence of neutrino oscillations, 205 +/- 17 (syst) events are expected to be detected while only 58 muon neutrino event candidates are observed. A fit to the neutrino rate and energy spectrum, assuming three neutrino flavors and normal mass hierarchy yields a best-fit mixing angle sin…
Precision electroweak measurements on the Z resonance
We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLD experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, $\MZ$ and $\GZ$, and its couplings to fermions, for example the $\rho$ parameter and the effective electroweak mixing angle, are precisely measured. The number of light neutrino species is determined to be 2.9840…
Optimal ferromagnetically-coated carbon nanotube tips for ultra-high resolution magnetic force microscopy
Using single-walled carbon nanotubes homogeneously coated with ferromagnetic metal as ultra-high resolution magnetic force microscopy probes, we investigate the key image formation parameters and their dependence on coating thickness. The crucial step of introducing molecular beam epitaxy for deposition of the magnetic coating allows highly controlled fabrication of tips with small magnetic volume, while retaining high magnetic anisotropy and prolonged lifetime characteristics. Calculating the interaction between the tips and a magnetic sample, including hitherto neglected thermal noise effects, we show that optimal imaging is achieved for a finite, intermediate-thickness magnetic coating, …