Martial Piotto

showing 2 related works from this author

1H and 13C HR-MAS spectroscopy of intact biopsy samples ex vivo and in vivo 1H MRS study of human high grade gliomas.

2004

High-resolution magic angle spinning (HR-MAS) one- and two-dimensional 1H and 13C nuclear magnetic resonance (NMR) spectroscopy has been used to study intact glioblastoma (GBM) brain tumour tissue. The results were compared with in vitro chemical extract and in vivo spectra. The resolution of 1H one-dimensional, 1H TOCSY and 13C HSQC HR-MAS spectra is comparable to that obtained on perchloric extracts. 13C HSQC HR-MAS spectra have been particularly useful for the identification of 37 different metabolites in intact biopsy tumours, excluding water and DSS components. To our knowledge, this is the most detailed assignment of biochemical compounds obtained in intact human tissue, in particular…

AdultMaleMagnetic Resonance SpectroscopyResolution (mass spectrometry)Statistics as TopicNuclear magnetic resonanceIn vivoBiopsyMagic angle spinningmedicineHumansRadiology Nuclear Medicine and imagingSpectroscopyNuclear Magnetic Resonance BiomolecularSpectroscopyAgedCarbon Isotopesmedicine.diagnostic_testChemistryBrain NeoplasmsMiddle AgedIn vitroNeoplasm ProteinsMolecular MedicineFemaleProtonsGlioblastomaHeteronuclear single quantum coherence spectroscopyEx vivoBiomarkersNMR in biomedicine
researchProduct

Determination of metabolite concentrations in human brain tumour biopsy samples using HR-MAS and ERETIC measurements.

2009

Accurate determination of the concentration of the metabolites contained in intact human biopsies of 10 glioblastoma multiforme samples was achieved using one-dimensional 1H high-resolution magic angle spinning (HR-MAS) NMR combined with ERETIC™ (electronic reference to in vivo concentrations) measurements. The amount of sample used ranged from 6.8 to 12.9 mg. Metabolite concentrations were measured in each sample using two methods: with DSS (2,2-dimethyl-2-silapentane-5-sulfonate sodium salt) as an internal reference and with ERETIC™ as an external electronically generated reference. The ERETIC™ signal was shown to be highly reproducible and did not affect the spectral quality. The concent…

Internal standardChromatographyMagnetic Resonance Spectroscopymedicine.diagnostic_testChemistryBrain NeoplasmsMetaboliteAnalytical chemistryHuman brainNeoplasm Proteinschemistry.chemical_compoundmedicine.anatomical_structureIn vivoBiopsymedicineMagic angle spinningBiomarkers TumorMolecular MedicineHumansRadiology Nuclear Medicine and imagingSample preparationProtonsSpectroscopyEx vivoAlgorithmsNMR in biomedicine