0000000000547872

AUTHOR

Katarzyna Dziarkowska

showing 2 related works from this author

Single hollow fiber SLM extraction of polyamines followed by tosyl chloride derivatization and HPLC determination

2007

Determination of polyamines in biological fluids possesses medical diagnostic relevance. Despite the vast panel of analytical methods developed for polyamines they are not applied in routine clinical usage, mainly due to the time and labor consuming sample preparation step and complicated derivatization procedures. Thus, new simpler methods are needed. This paper describes a single hollow fiber SLM extraction method of polyamines followed by simple pre-column derivatization with tosyl chloride and HPLC-UV analysis. The influence of different parameters such as the extraction time, organic phase composition, acceptor pH, donor pH, acceptor volume, donor volume and stirring speed on the trans…

hollow fiber membraneTime FactorspolyaminesBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryTosyl Compoundschemistry.chemical_compoundEnvironmental ChemistryHumansSample preparationFibersupported liquid membraneDerivatizationSpectroscopyChromatography High Pressure LiquidChromatographyextraction techniqueExtraction (chemistry)Reproducibility of ResultsMembranes ArtificialHydrogen-Ion ConcentrationAcceptor2 × 2 real matriceschemistryHollow fiber membraneAnalytica Chimica Acta
researchProduct

Studies of polyamines transport through liquid membranes with D2EHPA as a carrier.

2008

The transport of polyamines through the liquid membranes with di‐2‐ethylhexyl phosphoric acid (D2EHPA) was investigated. The study was performed in three main steps: liquid–liquid extraction (LLE), bulk liquid membrane (BLM) extraction, and supported liquid membrane (SLM) extraction. Equilibrium distribution experiments allowed determining the extraction constants and stoichiometric coefficients for each polyamine. It turned out that one amino group binds two molecules of carrier (one D2EHPA dimer) and the extractability of polyamine rises with the increase in number of function groups in the molecule. The BLM and SLM experiments showed that despite considerable differences in distribution …

Extraction (chemistry)Analytical chemistryFiltration and SeparationDi-(2-ethylhexyl)phosphoric acidMembranes ArtificialAcceptorHigh-performance liquid chromatographyextraction equilibriumAnalytical ChemistryChemical kineticschemistry.chemical_compoundKineticsliquid membranesMembranechemistryLiquid–liquid extractiondi-2-ethylhexyl phosphoric acidtransport mechanismPolyaminesPhosphoric acidChromatography High Pressure LiquidJournal of separation science
researchProduct