0000000000558124

AUTHOR

M. Kowal

First observation of high-K isomeric states in $$^{249}$$Md and $$^{251}$$Md

Decay spectroscopy of the odd-proton nuclei $^{249}$Md and $^{251}$Md has been performed. High-K isomeric states were identified for the first time in these two nuclei through the measurement of their electromagnetic decay. An isomeric state with a half-life of 2.8(5) ms and an excitation energy $\ge 910$ keV was found in $^{249}$Md. In $^{251}$Md, an isomeric state with a half-life of 1.4(3) s and an excitation energy $\ge 844$ keV was found. Similarly to the neighbouring $^{255}$Lr, these two isomeric states are interpreted as 3 quasi-particle high-K states and compared to new theoretical calculations. Excited nuclear configurations were calculated within two scenarios: via blocking nucle…

research product

Examining the generalizability of research findings from archival data

This research project benefitted from Ministry of Education (Singapore) Tier 1 Grant R-313-000-131-115 (to A. Delios), National Science Foundation of China Grants 72002158 (to H.T.) and 71810107002 (to H.T.), grants from the Knut and Alice Wallenberg Foundation (to A. Dreber) and the Marianne and Marcus Wallenberg Foundation (through a Wallenberg Scholar grant; to A. Dreber), Austrian Science Fund (FWF) Grant SFB F63 (to A. Dreber), grants from the Jan Wallander and Tom Hedelius Foundation (Svenska Handelsbankens Forskningsstiftelser; to A. Dreber), and an Research & Development (R&D) research grant from Institut Européen d'Administration des Affaires (INSEAD) (to E.L.U.). Dmitrii Dubrov, o…

research product

Development of silicon pad detectors and readout electronics for a Compton camera

Abstract Applications in nuclear medicine and bio-medical engineering may profit using a Compton camera for imaging distributions of radio-isotope labelled tracers in organs and tissues. These applications require detection of photons using thick position-sensitive silicon sensors with the highest possible energy and good spatial resolution. In this paper, research and development on silicon pad sensors and associated readout electronics for a Compton camera are presented. First results with low-noise, self-triggering VATAGP ASIC's are reported. The measured energy resolution was 1.1 keV FWHM at room temperature for the 241 Am photo-peak at 59.5 keV .

research product

In COVID-19 Health Messaging, Loss Framing Increases Anxiety with Little-to-No Concomitant Benefits: Experimental Evidence from 84 Countries

Contains fulltext : 284232.pdf (Publisher’s version ) (Closed access) The COVID-19 pandemic (and its aftermath) highlights a critical need to communicate health information effectively to the global public. Given that subtle differences in information framing can have meaningful effects on behavior, behavioral science research highlights a pressing question: Is it more effective to frame COVID-19 health messages in terms of potential losses (e.g., "If you do not practice these steps, you can endanger yourself and others") or potential gains (e.g., "If you practice these steps, you can protect yourself and others")? Collecting data in 48 languages from 15,929 participants in 84 countries, we…

research product

Silicon detector for a Compton camera in nuclear medical imaging

Electronically collimated gamma ca\-me\-ras based on Com\-pton scattering in silicon pad sensors may improve imaging in nuclear medicine and bio-medical research. The work described here concentrates on the silicon pad detector developed for a prototype Compton camera. The silicon pad sensors are read out using low noise VLSI CMOS chips and novel fast triggering chips. Depending on the application a light weight and dense packaging of sensors and its readout electronics on a hybrid is required. We describe the silicon pad sensor and their readout with the newly designed hybrid. %The silicon detector of a Compton camera %may contain up to $10^5$~analogue channels requiring %a fast and low co…

research product

Early outcomes and complications following cardiac surgery in patients testing positive for coronavirus disease 2019: An international cohort study

The outbreak of severe acute respiratory syndromecoronavirus-2, the cause of coronavirus disease 2019 (COVID-19) in December 2019 represented a global emergency accounting for more than 2.5 million deaths worldwide.1 It has had an unprecedented influence on cardiac surgery internationally, resulting in cautious delivery of surgery and restructuring of services.2 Understanding the influence of COVID-19 on patients after cardiac surgery is based on assumptions from other surgical specialties and single-center studies. The COVIDSurg Collaborative conducted a multicenter cohort study, including 1128 patients, across 235 hospitals, from 24 countries demonstrating perioperative COVID-19 infection…

research product

Machine learning risk prediction of mortality for patients undergoing surgery with perioperative SARS-CoV-2: the COVIDSurg mortality score

The British journal of surgery 108(11), 1274-1292 (2021). doi:10.1093/bjs/znab183

research product