0000000000577901

AUTHOR

E. González

showing 14 related works from this author

New measurement of the 242Pu(n,γ) cross section at n-TOF-EAR1 for MOX fuels: Preliminary results in the RRR

2016

The spent fuel of current nuclear reactors contains fissile plutonium isotopes that can be combined with 238U to make mixed oxide (MOX) fuel. In this way the Pu from spent fuel is used in a new reactor cycle, contributing to the long-term sustainability of nuclear energy. The use of MOX fuels in thermal and fast reactors requires accurate capture and fission cross sections. For the particular case of 242Pu, the previous neutron capture cross section measurements were made in the 70’s, providing an uncertainty of about 35% in the keV region. In this context, the Nuclear Energy Agency recommends in its “High Priority Request List” and its report WPEC-26 that the capture cross section of 242Pu…

Nuclear reactionnTOFQC1-999Nuclear engineeringContext (language use)CERN nTOFNeutron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyPhysics and Astronomy (all)Nuclear reactorsReactors nuclears0103 physical sciencesCERNNeutron cross sectionNuclear Physics - ExperimentNeutronddc:530242Pu neutron capture010306 general physicsMOX fuelNeutrons:Energies::Energia nuclear [Àrees temàtiques de la UPC]Fissile materialCross section:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsNuclear reactionSpent nuclear fuelNeutron temperature13. Climate actionneutron time-of-flight measurement
researchProduct

7Be(n,α) and 7Be(n,p) cross-section measurement for the cosmological lithium problem at the n-TOF facility at CERN

2017

One of the most puzzling problems in Nuclear Astrophysics is the “Cosmological Lithium Problem”, i.e the discrepancy between the primordial abundance of \(^{7}\)Li observed in metal poor halo stars (Asplund et al. in Astrophys J 644:229–259, 2006, [1]), and the one predicted by Big Bang Nucleosynthesis (BBN). One of the reactions that could have an impact on the problem is \(^{7}\)Be(n,p)\(^{7}\)Li. Despite of the importance of this reaction in BBN, the cross-section has never been directly measured at the energies of interest for BBN. Taking advantage of the innovative features of the second experimental area at the n\(\_\)TOF facility at CERN (Sabate-Gilarte et al. in Eur Phys J A 53:210,…

AstrofísicanTOFQC1-999chemistry.chemical_elementNeutronAstrophysics01 natural sciences7. Clean energyNuclear physicsPhysics and Astronomy (all)Big Bang nucleosynthesisNucleosynthesisCERN0103 physical sciencesNuclear astrophysicsAstrophysics::Solar and Stellar AstrophysicsNeutron010306 general physicsNuclear ExperimentAstrophysics::Galaxy Astrophysics:Energies::Energia nuclear [Àrees temàtiques de la UPC]NeutronsPhysicsAlphaLarge Hadron Collider:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsStarschemistryLithiumHaloNucleosynthesisNucleosíntesi
researchProduct

Pulse shape analysis of liquid scintillators for neutron studies

2002

The acquisition of signals from liquid scintillators with Flash ADC of high sampling rate ð 1G S=sÞ has been investigated. The possibility to record the signal waveform is of great advantage in studies with g’s and neutrons in a high count-rate environment, as it allows to easily identify and separate pile-up events. The shapes of pulses produced by g-rays and neutrons have been studied for two different liquid scintillators, NE213 and C6D6: A 1-parameter fitting procedure is proposed, which allows to extract information on the particle type and energy. The performance of this method in terms of energy resolution and n=g discrimination is analyzed, together with the capability to identify a…

PhysicsNuclear and High Energy Physicsbusiness.industryFlash ADCScintillatorSignalParticle detectorNuclear magnetic resonanceOpticsWaveformNeutron detectionNeutronbusinessInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The n_TOF facility: Neutron beams for challenging future measurements at CERN

2016

The CERN n TOF neutron beam facility is characterized by a very high instantaneous neutron flux, excellent TOF resolution at the 185 m long flight path (EAR-1), low intrinsic background and coverage of a wide range of neutron energies, from thermal to a few GeV. These characteristics provide a unique possibility to perform high-accuracy measurements of neutron-induced reaction cross-sections and angular distributions of interest for fundamental and applied Nuclear Physics. Since 2001, the n TOF Collaboration has collected a wealth of high quality nuclear data relevant for nuclear astrophysics, nuclear reactor technology, nuclear medicine, etc. The overall efficiency of the experimental prog…

AstrofísicanTOF[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]QC1-999Nuclear TheoryNeutronAstrophysics01 natural sciences7. Clean energylaw.inventionNuclear physicsPhysics and Astronomy (all)Neutron fluxlaw0103 physical sciencesCERNNuclear astrophysicsNeutronSpallation010306 general physicsNuclear ExperimentPhysics:Energies::Energia nuclear [Àrees temàtiques de la UPC]NeutronsLarge Hadron Collider:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsNuclear dataNuclear reactorNeutron radiationAccelerators and Storage Rings3. Good health13. Climate action
researchProduct

The Nuclear astrophysics program at n_TOF (CERN)

2017

An important experimental program on Nuclear Astrophysics is being carried out at the n_TOF since several years, in order to address the still open issues in stellar and primordial nucleosynthesis. Several neutron capture reactions relevant to s-process nucleosynthesis have been measured so far, some of which on important branching point radioisotopes. Furthermore, the construction of a second experimental area has recently opened the way to challenging measurements of (n, charged particle) reactions on isotopes of short half-life. The Nuclear Astrophysics program of the n_TOF Collaboration is here described, with emphasis on recent results relevant for stellar nucleosynthesis, stellar neut…

Nuclear reactionAstrofísicaAstrophysics and AstronomyCross-sectionnTOFQC1-999Astrophysics::High Energy Astrophysical PhenomenaNeutron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Astrophysics01 natural sciences7. Clean energyn_TOF nuclear astrophysics CERNNuclear physicsPhysics and Astronomy (all)Stellar nucleosynthesisBig Bang nucleosynthesisNucleosynthesis0103 physical sciencesCERNNuclear astrophysicsAstrophysics::Solar and Stellar AstrophysicsNuclear Physics - ExperimentNeutronNeutron induced nuclear reactions010306 general physicsNuclear ExperimentAstrophysics::Galaxy AstrophysicsPhysics:Energies::Energia nuclear [Àrees temàtiques de la UPC]Neutrons:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsNuclear reactionNeutron capture13. Climate actionNeutron sourceAstrophysics::Earth and Planetary Astrophysics[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]NucleosynthesisNucleosíntesi
researchProduct

The 33S(n,α)30Si cross section measurement at n TOF-EAR2 (CERN): From 0.01 eV to the resonance region

2017

The 33S(n,α)30Si cross section measurement, using 10B(n,α) as reference, at the n TOF Experimental Area 2 (EAR2) facility at CERN is presented. Data from 0.01 eV to 100 keV are provided and, for the first time, the cross section is measured in the range from 0.01 eV to 10 keV. These data may be used for a future evaluation of the cross section because present evaluations exhibit large discrepancies. The 33S(n,α)30Si reaction is of interest in medical physics because of its possible use as a cooperative target to boron in Neutron Capture Therapy (NCT).

Nuclear reactionnTOFNeutron therapyQC1-999chemistry.chemical_elementNeutron01 natural sciencesResonance (particle physics)Nuclear physicsCross section (physics)Physics and Astronomy (all)0103 physical sciencesCERNNeutronddc:530010306 general physicsBoronPhysicsNeutrons:Energies::Energia nuclear [Àrees temàtiques de la UPC]Range (particle radiation)Large Hadron Collidercross sectionReaccions nuclears:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsNuclear reactionNeutron capturechemistryNuclear reactions
researchProduct

The 236U neutron capture cross-section measured at the n TOF CERN facility

2016

International audience; The $^{236}$U isotope plays an important role in nuclear systems, both for future and currently operating ones. The actual knowledge of the capture reaction of this isotope is satisfactory in the thermal region, but it is considered insufficient for Fast Reactor and ADS applications. For this reason the $^{236} \text{U}(n, \gamma)$ reaction cross-section has been measured for the first time in the whole energy region from thermal energy up to 1 MeV at the n_TOF facility with two different detection systems: an array of C$_6$D$_6$ detectors, employing the total energy deposited method, and a 4$\pi$ total absorption calorimeter (TAC), made of 40 BaF$_2$ crystals. The t…

Nuclear reactionnTOFQC1-999Neutron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyNuclear physicsPhysics and Astronomy (all)Cross section (physics)0103 physical sciencesCERNNeutron cross sectionNuclear Physics - Experimentddc:530Neutron010306 general physicsAbsorption (electromagnetic radiation)PhysicsNeutrons:Energies::Energia nuclear [Àrees temàtiques de la UPC]IsotopeCross sectionReaccions nuclears:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsResonanceNuclear reactionCalorimeter13. Climate actionNuclear reactions
researchProduct

High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility

2016

The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n-TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented. © The Authors, published by EDP Sciences, 2017.

Nuclear reactionnTOFQC1-999Neutron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyNuclear physicsCross section (physics)Physics and Astronomy (all)Nuclear reactorsReactors nuclears0103 physical sciencesThermalCERNNeutronddc:530Nuclear Physics - Experiment010306 general physicsPhysics:Energies::Energia nuclear [Àrees temàtiques de la UPC]NeutronsRange (particle radiation)Large Hadron Collider:Física [Àrees temàtiques de la UPC]Cross section010308 nuclear & particles physicsPhysicsRadiative captureNuclear energyNuclear reactionEnergia nuclearEnergy (signal processing)
researchProduct

The measurement programme at the neutron time-of-flight facility n_TOF at CERN

2016

Neutron-induced reaction cross sections are important for a wide variety of research fields ranging from the study of nuclear level densities, nucleosynthesis to applications of nuclear technology like design, and criticality and safety assessment of existing and future nuclear reactors, radiation dosimetry, medical applications, nuclear waste transmutation, accelerator-driven systems and fuel cycle investigations. Simulations and calculations of nuclear technology applications largely rely on evaluated nuclear data libraries. The evaluations in these libraries are based both on experimental data and theoretical models. CERN’s neutron time-of-flight facility n TOF has produced a considerabl…

EngineeringNuclear transmutationQC1-999Nuclear engineering[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesNuclear physicsPhysics and Astronomy (all)0103 physical sciences:Física::Electromagnetisme [Àrees temàtiques de la UPC]ddc:530Nuclear Physics - ExperimentNeutron010306 general physicsNeutrons:Energies::Energia nuclear [Àrees temàtiques de la UPC]Large Hadron Collider010308 nuclear & particles physicsbusiness.industryPhysicsNuclear dataRadioactive wasteNuclear technologyBeamlineCriticalitybusinessEPJ Web of Conferences
researchProduct

Measurement of the 241Am neutron capture cross section at the n-TOF facility at CERN

2016

New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241 Am(n,γ) cross section at the n TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental …

Nuclear reactionNuclear transmutationnTOFQC1-999Neutron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyNuclear physicsPhysics and Astronomy (all)Cross section (physics)Nuclear reactorsReactors nuclears0103 physical sciencesCERNNeutron cross sectionNuclear Physics - Experimentddc:530Neutron010306 general physicsAbsorption (electromagnetic radiation)PhysicsNeutrons:Energies::Energia nuclear [Àrees temàtiques de la UPC]Large Hadron ColliderCross section:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsPhysicsNuclear reactionCalorimeter
researchProduct

Nuclear data activities at the n_TOF facility at CERN

2016

International audience; Nuclear data in general, and neutron-induced reaction cross sections in particular, are important for a wide variety of research fields. They play a key role in the safety and criticality assessment of nuclear technology, not only for existing power reactors but also for radiation dosimetry, medical applications, the transmutation of nuclear waste, accelerator-driven systems, fuel cycle investigations and future reactor systems as in Generation IV. Applications of nuclear data are also related to research fields as the study of nuclear level densities and stellar nucleosynthesis. Simulations and calculations of nuclear technology applications largely rely on evaluate…

Nuclear reactionU-235Nuclear transmutationnTOFCAPTURE CROSS-SECTIONNuclear dataTOTAL ABSORPTION CALORIMETERGeneral Physics and Astronomy[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]COLLABORATION7. Clean energy01 natural sciences3100PHYSICSNuclear physicsPhysics and Astronomy (all)neutronDESIGNRadiation dosimetry0103 physical sciencesCERNn_TOFNuclear Physics - ExperimentNeutron010306 general physicsnuclear data n_TOF CERNPhysics:Energies::Energia nuclear [Àrees temàtiques de la UPC]NeutronsFRAGMENT ANGULAR-DISTRIBUTIONLarge Hadron Colliderntof:Física [Àrees temàtiques de la UPC]Cross section010308 nuclear & particles physicscernExperimental dataRadioactive wasteNuclear datanuclear dataNATURAL SCIENCES. Physics.Radiació--DosimetriaPRIRODNE ZNANOSTI. Fizika.Nuclear technologyCAPTURE CROSS-SECTION TOTAL ABSORPTION CALORIMETER FRAGMENT ANGULAR-DISTRIBUTION NEUTRON TH-232 U-235 C6D6 COLLABORATION PHYSICS DESIGN.NEUTRONTH-232C6D6
researchProduct

SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study

2021

Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…

MaleCOVID-19 Vaccinesafe surgery; vaccination modelling; COVID-19Vascular damage Radboud Institute for Health Sciences [Radboudumc 16]MULTICENTERComorbidity030230 surgery0302 clinical medicinephase 3 clinical trial (topic)Case fatality rateProspective StudiesSARS-CoV-2 Vaccination Safe surgeryCOVID-19/epidemiologySARS-CoV-2 ; vaccination ; safe surgeryeducation.field_of_studycase fatality rateVaccinationVaccinationAdolescent; Adult; Aged; COVID-19; COVID-19 Vaccines; Comorbidity; Elective Surgical Procedures; Female; Humans; Male; Middle Aged; Postoperative Complications; Preoperative Period; Prospective Studies; SARS-CoV-2; Vaccination; Young Adulthealth care policyElective Surgical Procedures030220 oncology & carcinogenesisvaccination modellingPreoperative PeriodCOVID-19; SARS-CoV-2; cancer; vaccination; outcome; mortality; infection; modellingCohort studyprospective studyHumanmedicine.medical_specialtyArticle03 medical and health sciencesSARS-CoV-2 vaccinationSDG 3 - Good Health and Well-beingCOVID-19 Vaccines/pharmacologyHumansVaccination/methodsElective surgeryeducationAgedScience & TechnologyElective Surgical Procedureadult; aged; Article; cancer grading; cancer surgery; case fatality rate; computer assisted tomography; elective surgery; female; follow up; health care policy; human; incidence; infection rate; infection risk; major clinical study; male; middle aged; mortality; outcome assessment; phase 3 clinical trial (topic); preoperative care; prospective study; sensitivity analysis; seroprevalence; Severe acute respiratory syndrome coronavirus 2; vaccination; young adult; COVID-19; COVID-19 Vaccines; Comorbidity; Elective Surgical Procedures; Postoperative Complications; Preoperative Period; SARS-CoV-2; Vaccination; surgery.Cura preoperatòriamajor clinical studymortalityinfectionProspective StudieincidenceSurgeryHuman medicinePostoperative Complication610 Medizin und GesundheitAcademicSubjects/MED00910Settore MED/18 - CHIRURGIA GENERALESettore MED/29 - CHIRURGIA MAXILLOFACCIALEcomputer assisted tomographyESTUDOS PROSPECTIVOSsurgerysafe surgeryPostoperative Complicationssensitivity analysisSevere acute respiratory syndrome coronavirus 2preoperative careVacunacióProspective cohort studyseroprevalenceIncidence (epidemiology)covidElective Surgical Procedures/methodsMiddle Agedcancer gradingCOVID vaccinationoutcome/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_beingSARS-CoV-2; vaccination; surgeryOriginal ArticleFemalecancer surgeryAcademicSubjects/MED00010Life Sciences & BiomedicineAdultCOVID-19 VaccinesAdolescentinternational prospective cohort studyPostoperative Complications/prevention & controlPopulationinfection rateSARS-CoV-2/immunologyNOmodellingYoung Adultmedicinefollow upcancerddc:610infection riskoutcome assessmentLS7_4business.industrySARS-CoV-2Number needed to vaccinatePreoperative careCOVID-193126 Surgery anesthesiology intensive care radiologySettore MED/18Reconstructive and regenerative medicine Radboud Institute for Health Sciences [Radboudumc 10]elective surgeryEmergency medicinebusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyThe British Journal of Surgery
researchProduct

Premorbid Adjustment and IQ in Patients With First-Episode Psychosis: A Multisite Case-Control Study of Their Relationship With Cannabis Use

2020

Abstract Psychotic patients with a lifetime history of cannabis use generally show better cognitive functioning than other psychotic patients. Some authors suggest that cannabis-using patients may have been less cognitively impaired and less socially withdrawn in their premorbid life. Using a dataset comprising 948 patients with first-episode psychosis (FEP) and 1313 population controls across 6 countries, we examined the extent to which IQ and both early academic (Academic Factor [AF]) and social adjustment (Social Factor [SF]) are related to the lifetime frequency of cannabis use in both patients and controls. We expected a higher IQ and a better premorbid social adjustment in psychotic p…

MalecognitionIntelligenceComorbiditySUBSTANCE USE DISORDERS0302 clinical medicineSettore MED/48 -Scienze Infermierist. e Tecn. Neuro-Psichiatriche e Riabilitat.MedicinePREDICTORSRISKeducationeducation.field_of_studybiologyCognitionMiddle AgedPsychosocial FunctioningsociabilityPsychiatry and Mental healthSchizophreniaFemaleMarijuana UseSocial AdjustmentMENTAL-HEALTHAdultmedicine.medical_specialtyPsychosisAdolescentPopulation1ST EPISODEDRUG-USEpreillnessSettore MED/01 - Statistica MedicaYoung Adult03 medical and health sciencesAGESettore M-PSI/08 - Psicologia ClinicaHumansCognitive skilleducationPsychiatrySettore MED/25 - Psichiatriabusiness.industryCase-control studypreillnebiology.organism_classificationmedicine.diseaseEDUCAÇÃO030227 psychiatryschizophreniaPsychotic DisordersCase-Control StudiesONSETCannabisNEUROCOGNITIONbusinessmarijuanaNeurocognitive030217 neurology & neurosurgeryRegular ArticlesSchizophrenia Bulletin
researchProduct

Measurement of the α ratio and (n, γ) cross section of 235U from 0.2 to 200 eV at n_TOF

2020

We measured the neutron capture-to-fission cross-section ratio (α ratio) and the capture cross section of 235U between 0.2 and 200 eV at the n_TOF facility at CERN. The simultaneous measurement of neutron-induced capture and fission rates was performed by means of the n_TOF BaF2 Total Absorption Calorimeter (TAC), used for detection of γ rays, in combination with a set of micromegas detectors used as fission tagging detectors. The energy dependence of the capture cross section was obtained with help of the 6 Li(n,t) standard reaction determining the n_TOF neutron fluence; the well-known integral of the 235U(n, f ) cross section between 7.8 and 11 eV was then used for its absolute normalizat…

researchProduct