N Marchese
Low Dose-Rate, High Total Dose Set-Up for Rad-Hard CMOS I/O Circuits Testing
In this paper, the planning of low dose-rate, high total dose testing campaign for I/O circuits is reported. In particular, the paper describes all development steps, starting from the rad-hard I/O circuits design and the implementation of the test-chip, which is meant to allow comparative testing between rad-hard and standard devices. The designed experimental setup permits in situ measurements, therefore the circuits behavior can be remotely monitored for very long periods. This feature enables low dose-rate testing up to very high dose.
Valutazione della fluenza di neutroni di origine cosmica a livello del suolo
Lo studio degli effetti delle radiazioni neutroniche sul funzionamento dei componenti che fanno parte dei più comuni sistemi elettronici comporta lo studio della fluenza neutronica di origine cosmica a livello del suolo. Infatti la sorgente primaria dei neutroni in atmosfera è principalmente individuabile nell’interazione tra i raggi cosmici di origine solare ed i vari strati dell’atmosfera. Il campo neutronico pertanto non è dunque costante ma dipende fortemente dai cicli di attività solare. In questo lavoro sono presentati i risultati di due cicli di misurazioni del “dose rate” da neutroni nei periodi 21-28 Febbraio e 29 Febbraio-7 Marzo 2012. La strumentazione utilizzata è costituita dal…
Indoor Fast Neutron Generator for Biophysical and Electronic Applications
This study focuses the attention on an indoor fast neutron generator for biophysical and electronic applications. More specifically, the findings obtained by several simulations with the MCNP Monte Carlo code, necessary for the realization of a shield for indoor measurements, are presented. Furthermore, an evaluation of the neutron spectrum modification caused by the shielding is reported. Fast neutron generators are a valid and interesting available source of neutrons, increasingly employed in a wide range of research fields, such as science and engineering. The employed portable pulsed neutron source is a MP320 Thermo Scientific neutron generator, able to generate 2.5 MeV neutrons with a …
Dangerous Effects Induced on Power MOSFETs by Terrestrial Neutrons
This paper investigates the effects that terrestrial neutrons can induce on power MOSFETs when they are biased during their normal working conditions especially in inverters for photovoltaic applications. After a brief review of power MOSFETs failure phenomena caused by neutron irradiation (with emphasis on so called “Single Event Effects” (SEE)), the results of an accelerated test performed with the Am-Be source at the University of Palermo are discussed.