0000000000646294

AUTHOR

C. Molins Legua

Generalised H-point standard addition method for the isolation of the analyte signal from the sample signal when coelution of unknown compounds occurs in liquid chromatography.

The generalised H-point standard addition method (GHPSAM) is proposed for isolating the analytical signal of an analyte from the signal of an unknown sample. Samples containing two and three coeluting compounds have been analysed. The accuracy of the predictions depends on the shape of the analyte and interferent spectra but not on the degree of chromatographic overlap. This methodology involves the location of linear intervals for the unknown interference spectrum from the spectrum of the sample. Once the linear interval has been found the selection of three wavelengths within the interval will allow the cancellation of the signal of the unknown interferent. The method has been applied to …

research product

Determination of ammonia and primary amine compounds and Kjeldahl nitrogen in water samples with a modified Roth's fluorimetric method.

Abstract A method for the simultaneous determination of primary amino groups and ammonium ion has been proposed. The method is based in solution derivatization with o-Phthaldialdehyde/N-acetyl-cisteine (OPA/NAC) and fluorescence measurement of the formed isoindols. Analytical characteristics and description of the developed procedure have been provided. The calibration graphs for ammonium (up to 1.44 mg L−1 of N) and methylamine as primary amino model compound (up to 0.282 mg L−1 of N), were obtained. Bivariate and multivariate calibration models have been tested. The limits of detection were 0.07 mg L−1 of N and 0.004 mg L−1 of N for ammonium and amine, respectively. The procedure was firs…

research product

Rapid fluorimetric assay for primary amine groups in water samples

Bond Elut C(18) solid-phase extraction cartridges were used for pre-concentration followed by derivatization with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) of primary amines in water. Optimal conditions were: conditioning the cartridges with borate buffer pH 10.4, retention of the primary amines, addition of the OPA-NAC(3.7 mmol L(-1)) 1:1 molar ratio and borate buffer pH 8, elution of the isoindol with MeOH-borate buffer (9:1) pH 10.2 and fluorescence measurement. The equations of the calibration graphs for methylamine, ethylamine, propylamine, butylamine, pentylamine, and beta-phenylethylamine at lambda(excitation)=330 nm and lambda(emission)=440 nm, in the optimal conditions are pres…

research product

Sensitive determination of aliphatic amines in water by high-performance liquid chromatography with chemiluminescence detection.

A sensitive method has been developed for liquid chromatographic determination of short aliphatic amines in water samples. Analytes are preconcentrated and dansylated on solid sorbents (C18 solid-phase extraction cartridges). The dansyl derivatives are chromatographed and post-column mixed with peroxyoxalate (TCPO) and H2O2 in order to perform chemiluminescence detection. Optimal results have been obtained using a sample volume of 5 ml. The method has been applied to the quantification or screening of several aliphatic amines: methylamine, ethylamine, butylamine, diethylamine, pentylamine and hexylamine. The screening procedure has been developed including also polyamines (putrescine, cadav…

research product

Analysis of primary aliphatic short-chain monoamines by LC in water samples

Abstract Several derivatization procedures with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) were compared for a rapid analysis of primary aliphatic short-chain monoamines in water samples by HPLC using a LiChorospher analytical separation column (100RP18 125 mm ×4  mm i.d., 5 μm). Both the solution and the solid-support assisted off-line derivatization on C18 SPE cartridges were inadequate options because of beginning degradation processes of the instable isoindol derivatives during their transfer to the analytical column. This problem was precluded with the on-column or solid-support assisted on-line derivatization. In the last mentioned procedure, the derivatization took place in a Hype…

research product

Creatinine determination in urine samples by batchwise kinetic procedure and flow injection analysis using the Jaffé reaction: chemometric study

The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval w…

research product

Amphetamine and methamphetamine determination in urine by reversed-phase high-performance liquid chromatography with sodium 1,2-napthoquinone 4-sulfonate as derivatizing agent and solid-phase extraction for sample clean-up

A rapid method is described for the identification and determination of amphetamine and methamphetamine in human urine samples by liquid chromatography with UV-Vis detection. The samples were transferred onto a C18 solid-phase extraction column and chromatographed on a Hypersil ODS RP C18, 5 microns (250 x 4 mm I.D.) with an acetonitrile-water elution gradient containing propylamine. Under these conditions, the amines are eluted with a short retention time. The procedure has been applied to the determination of amphetamine and methamphetamine in the range 0.3-4.0 micrograms/ml in spiked urine samples. The detection limits at 280 nm were 4 and 2 ng/ml for amphetamine and methamphetamine, res…

research product

Preconcentration and dansylation of aliphatic amines using C18 solid-phase packings

Abstract Precolumn preconcentration and derivatization on solid sorbents (Bond Elut C18 solid-phase extraction cartridges) of low-molecular-mass aliphatic amines in water samples have been performed using dansyl chloride (Dns-Cl) as derivatization reagent. Conditions for analyte preconcentration and derivatization such as volume sample, reagent concentration, time, pH and temperature reaction were optimised. On the basis of these studies a rapid and sensitive method for screening of aliphatic amines in waters is presented. Up to volumes of 5 ml, samples are drawn through the sorbent, the analytes retained are dansylated at basic pH, at 100 °C for 10 min or 85 °C for 15 min. The derivatized …

research product

Determination of methamphetamine in urine samples with sodium 1,2-naphthoquinone-4-sulphonate

Optimal conditions have been studied for the determination of methamphetamine in urine samples by an extractive-spectrophotometric method with sodium 1,2-naphthoquinone-4-sulphonate (NQS) as reagent. These conditions are: NaHCO3 pH 10, NQS 6.3 × 10−3 mol/l and heating for 5 min at 45°C. The accuracy and precision of the method were tested. The detection limits were 0.2 mg/l in the standard and 0.9 mg/l when 5 ml of urine sample were taken. The standard deviation of blank urine was evaluated from 12 different samples. The relative errors found in the determination of methamphetamine in urine were lower than 10% if the methamphetamine-amphetamine ratio was higher than 4.

research product