0000000000654094

AUTHOR

S. Fischer

Calibration of high voltages at the ppm level by the difference of $$^{83{\mathrm{m}}}$$ 83m Kr conversion electron lines at the KATRIN experiment

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at − 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $$^{83{\mathrm{m}}}$$ 83m Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN’s commissioning measurements …

research product

Untersuchungen zur Struktur der Paraffinschmelzen mit Hilfe der depolarisierten Lichtstreuung

Es wurde die depolarisierte Lichtstreuung von Paraffinschmelzen in Abhangikeit von der Kettenlange und der Temperatur untersucht. Um eine Aussage uber die in der Schmelze vorhandene Orientierungskorrelation zwischen den Kettensegmenten machen zu konnen, wurden die stosinduzierten Streukomponenten mit einem Ramanspektrometer bestimmt und von der mit einer konventionelle Lichtstreuapparatur gemessenen Gesamtstreuung abgezogen.

research product

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. An integral energy analysis will be performed by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m[superscript 3], and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips ha…

research product

Improved Upper Limit on the Neutrino Mass from a Direct Kinematic Method by KATRIN

We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic end point at 18.57 keV gives an effective neutrino mass square value of (−1.0−1.1+0.9) eV2. From this, we derive an upper limit of 1.1 eV (90% confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a …

research product

Field and petrographic evidence for partial melting of TTG gneisses from the central region of the mainland Lewisian complex, NW Scotland

The central region of the mainland Lewisian complex is dominated by granulite-facies tonalite–trondhjemite–granodiorite (TTG) gneisses that are highly depleted in some mobile trace elements (Cs, Rb, Th and U) relative to amphibolite-facies TTG gneisses elsewhere in the Lewisian complex and to the average composition of TTG gneisses worldwide. Over almost half a century of research there has been vigorous debate as to the origin of this depletion, in particular with respect to the role of partial melting and melt loss. Here we provide field and petrographic evidence that TTG gneisses across the central region partially melted during granulite-facies (Badcallian) metamorphism. Partial melting…

research product

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium β-decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, …

research product

Eine neue Methode zur Messung der Skelettmuskeldurchblutung bei der arteriellen Verschlußkrankheit

Mit dem neu fur die Myokard-Szintigraphie eingefuhrten Radio-pharmakon „Cardiolite“ sind jetzt auch nichtinvasive Messungen der Durchblutung der Skelettmuskulatur mit geringer Strahlenbelastung moglich. In einer vom BGA zugelassenen Pilot-Studie uber-pruften wir die klinische Brauchbarkeit dieser theoretisch bestechenden Methode.

research product

Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at − 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two [superscript 83m]Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN’s commissioning measurements in July 2…

research product

IBZM-SPECT bei Neuroleptikatherapie

Mit IBZM — einem mit Jod-123 markierten Benzamid — ist es erstmalig moglich, die Dopamin-D2-Rezeptoren mit der Single-Photonen-Emissions-Computertomographie (SPECT) darzustellen. Das trotz der fehlenden ab-soluten Quantifizierung mit SPECT diese Methode hilfreich sein kann fur die Messung der D2-Rezeptoren, wurde schon von der Arbeitsgruppe von Brucke [1] dargestellt. Gegenstand unserer eigenen Studien war die Untersuchung der D2-Rezeptorbesetzung (RB) unter Haloperidol, Benperidol und Clozapin im Zusammenhang mit klinischen Daten und Prolaktinspiegeln.

research product

Archaean Intracrustal Differentiation from Partial Melting of Metagabbro--Field and Geochemical Evidence from the Central Region of the Lewisian Complex, NW Scotland

The central region of the mainland Lewisian gneiss complex of NW Scotland is a granulite-facies migmatite terrane. With the exception of ultramafic and rare calc-silicate rocks, all other lithologies partially melted during Neoarchaean, ultrahigh-temperature (Badcallian) metamorphism. The clearest evidence is preserved within large layered mafic^ultramafic bodies that exhibit macroscopic features diagnostic of anatexis. In situ partial melting of metagabbroic rocks produced patches and sheets of coarse-grained plagioclase-rich leucosome containing euhedral peritectic clinopyroxene.These leucosomes connect with larger, laterally continuous tonalite or trondhjemite sheets that record segregat…

research product

Field and petrographic evidence for partial melting of TTG gneisses from the central region of the mainland Lewisian complex, NW Scotland

The central region of the mainland Lewisian complex is dominated by granulite-facies tonalite–trondhjemite–granodiorite (TTG) gneisses that are highly depleted in some mobile trace elements (Cs, Rb, Th and U) relative to amphibolite-facies TTG gneisses elsewhere in the Lewisian complex and to the average composition of TTG gneisses worldwide. Over almost half a century of research there has been vigorous debate as to the origin of this depletion, in particular with respect to the role of partial melting and melt loss. Here we provide field and petrographic evidence that TTG gneisses across the central region partially melted during granulite-facies (Badcallian) metamorphism. Partial melting…

research product

Functionalized Magnetic Nano-particles for Selective Targeting and Sensing of Cells

research product

CCDC 878388: Experimental Crystal Structure Determination

Related Article: S.C.Koeberle, S.Fischer, D.Schollmeyer, V.Schattel, C.Grutter, D.Rauh, S.A.Laufer|2012|J.Med.Chem.|55|5868|doi:10.1021/jm300327h

research product