Membrane Fouling Mitigation in MBR via the Feast–Famine Strategy to Enhance PHA Production by Activated Sludge

2022

Fouling is considered one of the main drawbacks of membrane bioreactor (MBR) technology. Among the main fouling agents, extracellular polymeric substances (EPS) are considered one of the most impactful since they cause the decrease of sludge filterability and decline of membrane flux in the long term. The present study investigated a biological strategy to reduce the membrane-fouling tendency in MBR systems. This consisted of seeding the reactor with activated sludge enriched in microorganisms with polyhydroxyalkanoate (PHA) storage ability and by imposing proper operating conditions to drive the carbon toward intracellular (PHA) rather than extracellular (EPS) accumulation. For that purpos…

Settore ICAR/03 - Ingegneria Sanitaria-AmbientaleProcess Chemistry and Technologyextracellular polymeric substances (EPS) cake layer fouling control membrane bioreactor (MBR) polyhydroxyalkanoate (PHA) resistance in series (RIS) model soluble microbial products (SMP)Chemical Engineering (miscellaneous)Filtration and Separationextracellular polymeric substances (EPS); cake layer; fouling control; membrane bioreactor (MBR); polyhydroxyalkanoate (PHA); resistance in series (RIS) model; soluble microbial products (SMP)Membranes
researchProduct

Biopolymer Recovery from Aerobic Granular Sludge and Conventional Flocculent Sludge in Treating Industrial Wastewater: Preliminary Analysis of Differ…

2022

The recovery of biopolymers from sewage sludge could be a crucial step in implementing circular economy principles in wastewater treatment plants (WWTP). In this frame, the present study was aimed at evaluating the simultaneous production of polyhydroxyalkanoates (PHA) and extracellular polymeric substances (EPS) obtainable from the treatment of agro-industrial wastewater. Two biological enrichment systems, aerobic granular sludge (AGS) and a conventional activated sludge operating as a sequencing batch reactor (SBR), were monitored for 204 and 186 days, respectively. The maximum biopolymers accumulation capacity was close to 0.60 mgPHA-EPS gVSS−1 in the AGS when operating at 3 kgCODm…

wastewater treatmentsewage sludgeSettore ICAR/03 - Ingegneria Sanitaria-Ambientalebiopolymercircular economyaerobic granular sludge; biopolymers; circular economy; extracellular polymeric substances; polyhydroxyalkanoates; sewage sludge; wastewater treatmentGeography Planning and Developmentpolyhydroxyalkanoateaerobic granular sludgeAquatic Scienceextracellular polymeric substanceBiochemistryWater Science and TechnologyWater
researchProduct

Integrated production of biopolymers with industrial wastewater treatment: Effects of OLR on process yields, biopolymers characteristics and mixed mi…

2022

The production of polyhydroxyalkanoates (PHA) using industrial wastewaters as feedstocks is a current and challenging topic. This study investigated the production of biopolymers by a mixed microbial culture under different OLRs equal to 1 kgCOD m-3d-1 (Period 1), 2 kgCOD m-3d-1 (Period 2) and 3 kgCOD m-3d-1 (Period 3). The maximum PHA content was achieved in Period 2 (0.38 gPHA gTSS-1), whereas lower values were obtained in Period 1 (0.13 gPHA gTSS-1) and Period 3 (0.26 gPHA gTSS-1). Overall, the maximum PHA productivity resulted equal to 0.08 gPHA L-1h-1 (P2), 0.05 gPHA L-1h-1 (P1) and 0.04 gPHA L-1h-1 (P3), respectively. The molecular weight of the PHA increased from Period 1 (250 kDa) t…

Settore ICAR/03 - Ingegneria Sanitaria-AmbientaleProcess Chemistry and TechnologyIndustrial wastewater Mixed microbial cultures Organic loading rate Polyhydroxybutyrate SBR reactorsSafety Risk Reliability and QualityWaste Management and DisposalBiotechnologyJournal of Water Process Engineering
researchProduct

Enhanced Sewage Sludge Drying with a Modified Solar Greenhouse

2022

This work reports the results obtained with an innovative configuration of a closed-static solar greenhouse for sludge drying. The novelty of the solar greenhouse configuration consisted in using a forced ventilation system to provide hot air for sludge drying and the utilization of solar irradiation for energy supply. Wet sewage sludge (97% humidity) was successfully dried up to a residual humidity close to 5% after 25 days during wintertime. The increase of the airflow rate supplied under the sludge bed improved the sludge drying rate. Moreover, the fraction of volatile suspended solids decreased from 70% to 41% after 13 days, indicating that air supply promoted the simultaneous stabiliza…

Settore ICAR/03 - Ingegneria Sanitaria-Ambientaleexcess sludge reduction; convective drying; greenhouse; renewable energy; solar sludge drying; sustainable sludge managementGeneral Engineeringexcess sludge reduction convective drying greenhouse renewable energy solar sludge drying sustainable sludge managementClean Technologies; Volume 4; Issue 2; Pages: 407-419
researchProduct

SARS-CoV-2 infection and venous thromboembolism after surgery: an international prospective cohort study

2021

SARS-CoV-2 has been associated with an increased rate of venous thromboembolism in critically ill patients. Since surgical patients are already at higher risk of venous thromboembolism than general populations, this study aimed to determine if patients with peri-operative or prior SARS-CoV-2 were at further increased risk of venous thromboembolism. We conducted a planned sub-study and analysis from an international, multicentre, prospective cohort study of elective and emergency patients undergoing surgery during October 2020. Patients from all surgical specialties were included. The primary outcome measure was venous thromboembolism (pulmonary embolism or deep vein thrombosis) within 30 da…

Malepulmonary embolismInternationalitySettore MED/18 - CHIRURGIA GENERALEDeep veinVascular damage Radboud Institute for Health Sciences [Radboudumc 16]infectious diseasesCardiovascularSARS‐CoV‐2surgeryCOVID-19 ; SARS-CoV-2 ; deep vein thrombosis ; pulmonary embolism ; venous thromboembolismCohort StudiesPostoperative ComplicationsAnesthesiologyMedicine and Health SciencesProspective Studies610 Medicine & healthProspective cohort studyLung11 Medical and Health SciencesConfoundingHematologyMiddle AgedThrombosis17 Psychology and Cognitive SciencesCOVID-19; deep vein thrombosis; pulmonary embolism; SARS-CoV-2; venous thromboembolismPulmonary embolismCOVID-19; SARS-CoV-2; deep vein thrombosis; pulmonary embolism; venous thromboembolism.medicine.anatomical_structureCohortCOVID-19/complicationsPostoperative Complications/etiologyOriginal ArticleFemalePatient SafetyLife Sciences & BiomedicineCOVID-19; SARS-CoV-2; deep vein thrombosis; pulmonary embolism; venous thromboembolismHumanAdultmedicine.medical_specialtyAdolescentClinical Sciencesvenous thromboembolism610 Medicine & healthGlobalSurg CollaborativeVenous Thromboembolism/etiologydeep vein thrombosisNOCOVIDSurg CollaborativeYoung AdultMedicine General & InternalAge DistributionClinical ResearchCOVID‐19General & Internal MedicinemedicineHumansSex DistributionAgedScience & Technologybusiness.industrySARS-CoV-2PreventionNeurosciencesdeep vein thrombosiCOVID-19PneumoniaOdds ratioOriginal Articlesmedicine.diseaseSurgeryReconstructive and regenerative medicine Radboud Institute for Health Sciences [Radboudumc 10]Prospective StudieGood Health and Well BeingAnesthesiology and Pain MedicineHuman medicinePostoperative ComplicationCohort StudiebusinessVenous thromboembolism[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Insights on mechanisms of excess sludge minimization in an oxic-settling-anaerobic process under different operating conditions and plant configurati…

2022

In the present research, insights about the mechanisms of excess sludge minimization occurring in an oxic-settling-anaerobic (OSA) were provided. The investigation involved two systems operating in parallel. In particular, a conventional activated sludge (CAS) system as control and a system implementing the OSA process both having a pre-denitrification scheme were considered. Five periods (P1-P5) were studied, during which several operating conditions and configurations were tested. Specifically, the hydraulic retention time (HRT) in the anaerobic reactor of the OSA system (P1 8 h, P2-P3 12 h, P4 8 h, P5 12 h) and the return sludge from the anaerobic to the anoxic (scheme A) (P1-P2) or aero…

Environmental EngineeringSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleSewageExtracellular Polymeric Substance MatrixHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryActivated sludge Anaerobic side-stream reactor Biological nutrients removal Excess sludge minimization Oxic-settling-anaerobic (OSA) process Wastewater treatmentWaste Disposal FluidPollutionBioreactorsEnvironmental ChemistryAnaerobiosisChemosphere