0000000000745542

AUTHOR

Timo Karppinen

showing 4 related works from this author

Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.

2013

Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…

Materials scienceAcoustics and UltrasonicsBiophysics02 engineering and technology01 natural sciencesSensitivity and SpecificityImaging phantomBone and Bones010309 opticsOpticsLamb wavesFlexural strengthCoated Materials BiocompatibleBone Density0103 physical sciencesmedicineHumansRadiology Nuclear Medicine and imagingGuided wave testingRadiological and Ultrasound Technologyta114business.industryPhantoms ImagingLasersUltrasoundReproducibility of ResultsEquipment Design021001 nanoscience & nanotechnologyEquipment Failure Analysismedicine.anatomical_structureSoundAcoustic StimulationElasticity Imaging TechniquesUltrasonic sensorCortical bonePhase velocity0210 nano-technologybusinessPhotic StimulationDensitometryUltrasound in medicinebiology
researchProduct

Evaluating pulp stiffness from fibre bundles by ultrasound

2012

A non-destructive ultrasonic tester was developed to measure the stiffness of pulp bundles. The mechanical properties of pulp are important when estimating the behaviour of paper under stress. Currently available pulp tests are tedious and alter the fibres structurally and mechanically. The developed tester employs (933 ± 15) kHz tweezer-like ultrasonic transducers and time-of-flight measurement through (9.0 ± 2.5) mm long and (0.8 ± 0.1) mm thick fibre bundles kept at (19.1 ± 0.4) °C and (62 ± 1)% RH. We determined the stiffness of soft wood pulps produced by three kraft pulping modifications: standard kraft pulp, (5.2 ± 0.4) GPa, prehydrolysis kraft pulp, (4.3 ± 0.4) GPa, and alkali extra…

SoftwoodMaterials science0211 other engineering and technologiesmacromolecular substances02 engineering and technologyengineering.material01 natural scienceschemistry.chemical_compoundstomatognathic system0103 physical sciencesmedicineHemicelluloseComposite materialCellulose010301 acousticsInstrumentationEngineering (miscellaneous)021102 mining & metallurgyApplied MathematicsPapermakingPulp (paper)Stiffnessstomatognathic diseaseschemistryKraft processengineeringUltrasonic sensormedicine.symptomMeasurement Science and Technology
researchProduct

Photo-acoustic excitation and detection of guided ultrasonic waves in bone samples covered by a soft coating layer

2012

Photo-acoustic (PA) excitation was combined with skeletal quantitative ultrasound (QUS) for multi-mode ultrasonic assessment of human long bones. This approach permits tailoring of the ultrasonic excitation and detection so as to efficiently detect the fundamental flexural guided wave (FFGW) through a coating of soft tissue. FFGW is a clinically relevant indicator of cortical thickness. An OPO laser with tunable optical wavelength, was used to excite a photo-acoustic source in the shaft of a porcine femur. Ultrasonic signals were detected by a piezoelectric transducer, scanning along the long axis of the bone, 20-50 mm away from the source. Five femurs were measured without and with a soft …

Materials scienceengineering.material01 natural sciences030218 nuclear medicine & medical imaginglaw.invention010309 optics03 medical and health sciences0302 clinical medicineOpticsCoatinglaw0103 physical sciencesmedicineGuided wave testingta114business.industryWavelengthTransducermedicine.anatomical_structureengineeringCortical boneUltrasonic sensorsense organsPhase velocitybusinessWaveguideSPIE Proceedings
researchProduct

Selective Excitation of Guided Waves into Bone Phantoms by a Time-Delayed Laser Diode Array

2012

We excite selectively the Ao and So plate mode into an acrylic bone phantom using a laser diode array. This is done by controlling the time delay between the signals driving the array elements. Selective mode generation is important because it can potentially increase the sensitivity of in vivo osteoporosis screening.

Photoacoustic effect0303 health sciencesMaterials scienceLaser diodebusiness.industry030209 endocrinology & metabolismSelective excitationImaging phantomlaw.inventionOsteoporosis screeningUltrasonic imaging03 medical and health sciences0302 clinical medicineTime delayedOptics030301 anatomy & morphologylawbusinessSensitivity (electronics)2012 Symposium on Photonics and Optoelectronics
researchProduct