0000000000784793
AUTHOR
José Manuel González-méijome
Short-Term Changes in Light Distortion in Orthokeratology Subjects
Purpose. Quantifying adaptation to light distortion of subjects undergoing orthokeratology (OK) for myopia during the first month of treatment. Methods. Twenty-nine healthy volunteers (age: 22.34 ± 8.08 years) with mean spherical equivalent refractive error −2.10 ± 0.93D were evaluated at baseline and days 1, 7, 15, and 30 of OK treatment. Light distortion was determined using an experimental prototype. Corneal aberrations were derived from corneal topography for different pupil sizes. Contrast sensitivity function (CSF) was analyzed for frequencies of 1.50, 2.12, 3.00, 4.24, 6.00, 8.49, 12.00, 16.97, and 24.00 cpd under photopic conditions. Results. Average monocular values of all light di…
Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy
In the present study, samples of lotrafilcon A, balafilcon A, and galyfilcon A contact lenses were observed by atomic force microscopy (AFM) in tapping mode at areas ranging from 0.25 to 400 m2. Mean roughness (Ra), root-mean-square roughness (Rms) and maximum roughness (Rmax) in nanometers were obtained for the three lens materials at different magnifications. The three contact lenses showed significantly different surface topography. However, roughness values were dependent of the surface area to be analyzed. For a 1 m2 area, statistics revealed a significantly more irregular surface of balafilcon A (Ra = 6.44 nm; Rms = 8.30 nm; Rmax = 96.82 nm) compared with lotrafilcon A (Ra = 2.40 nm; …
Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact lens
Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-…
Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements
PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- …
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …
Tear film stability over a myopia control contact lens compared to a monofocal design
Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 +/- 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) …
Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic.
PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descriptive values for each parameter and the correlations with age and between different parameters were calculated. Vectorial components of refraction, including blur, were also derived from clinical refractive data and then analyzed. RESULTS: Several parameters changed significantly with …
Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"
Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375
Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes
Purpose: To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods: Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic ® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D…
Tributo al professor Miguel F. Refojo, PhD, DSc (1928---2016)
[Excerpt] July 21, 2016, Professor Miguel F. Refojo passed away at the age of 88 in Needham (Massachusetts). Saying that Miguel was one of the most renowned Spanish scientists of the second half of the XXth Century does not resembles its actual scientific size. Indeed, Miguel (or “Migüel” as most of his American friends pronounced his name) was a World Class scientist and inventor that will be forever linked to the advances in polymer science applied to the ophthalmic environment. His contributions in the biomedical field start “officially” in 1967 according to the National Library of Medline database (Pubmed-Medline). [...]
Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.
Purpose: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure. Methods: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared b…
Prevalence of corneal astigmatism before cataract surgery.
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects
A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…
Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses
Prova tipográfica (In Press)
Subjective Satisfaction in Long-term Orthokeratology Patients
Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …
Qualitative and quantitative characterization of the in vitro dehydration process of hydrogel contact lenses
Purpose: To investigate the in vitro dehydration process of conventional hydrogel and silicone-hydrogel contact lens materials. Methods: Eight conventional hydrogel and five silicone-hydrogel contact lenses were dehydrated under controlled environmental conditions on an analytical balance. Data were taken at 1-min intervals and dehydration curves of cumulative dehydration (CD), valid dehydration (VD), and dehydration rate (DR) were obtained. Several quantitative descriptors of the dehydration process were obtained by further processing of the information. Results: Duration of phase I (r 2 5 0.921), CD at end of phase I (r 2 5 0.971), time to achieve a DR of � 1%/min (r 2 5 0.946) were stron…
Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
In this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by b…
“In situ” corneal and contact lens thickness changes with high resolution OCT
Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant inc…
Visual acuity changes in presbyopic patients fitted with 3 multifocal contact lenses
Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation
Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…
Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar
Objetivo: Estudio in vivo de la luz dispersa que alcanza la retina en un paciente antes y despues de someterse a una queratoplastia penetrante (o sus siglas en ingles, PKP). Metodos: En un paciente varon de 65 anos con una ulcera corneal herpetica se midio la proporcion de luz dispersa que alcanza la retina tanto antes como despues de una PKP, utilizando para ello un metodo psicometrico denominado "de comparacion por compensacion" («Compensation comparison method», C-Quant straylightmeter, Oculus GmbH, Alemania). Resultados: La cantidad de luz dispersa que alcanza la retina medida antes de la cirugia fue elevada en comparacion con los valores obtenidos en estudios previos en sujetos normale…
Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses
Abstract: Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated withAFM over a surface of 25 lm2 according to previously published experimental setup. Average roughness (Ra) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The Ra value increased for balafilcon A (11.62–13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67–15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08–8.42 nm for unworn and worn samples, respectively), g…
Proclear EP vs placebo: visual outcomes and symptoms of asthenopia in nonpresbyopes and early presbyopes
Purpose: Over the past 20 years, many studies have reported the success of multifocal contact lenses (MFCLs) compared to monovision (MV), with only partial success being reported for MFCLs. Chronologically it appears there has been a gradual improvement in the performance of MFCLs. This study investigated whether this change in success is reflected in clinical practice. Method: Lens fit data collected from 2005 to 2009 by the International Contact Lens Prescribing Survey Consortium was reviewed for patients over 45 years old. A similar survey conducted from 1988 to 1989 was also reviewed and compared. Twelve published (Pubmed.gov) reports of clinical trials involving MFCLs and MV were revie…
Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manual refractometry
PURPOSE: The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. METHODS: Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range…
Oxygen Transmissibility of Piggyback Systems With Conventional Soft and Silicone Hydrogel Contact Lenses
To investigate the apparent oxygen transmissibility of various piggyback systems using conventional and silicone hydrogel soft contact lenses of different water content and permeability, rigid poly(methyl methacrylate), and rigid gas-permeable lenses of medium, high, and ultrahigh oxygen permeability. The aim of the study was to establish which material (rigid or hydrogel) is more representative of the resulting oxygen performance of piggyback systems. METHODS: The apparent oxygen transmissibility of 66 piggyback systems was measured with an electrochemical method. Eighteen of these combinations involved the use of silicone hydrogel contact lenses currently available. One hyperpermeable rig…
Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry
Purpose: To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry.Methods: Intraocular pressure was measured on the right eye of 153 patients (65 males, 88 females), aged from 21 to 85 years (mean +/- S.D., 55.5 +/- 15.2 years) with the ICare rebound tonometer at centre, and 2 mm from the limbus (in the nasal and temporal regions along the 0-180O corneal meridian).Results: Intraocular pressure values obtained with the ICare were 14.9 +/- 2.8; 14.1 +/- 2.5 and 14.5 +/- 2.7 mmHg at centre, nasal and temporal corneal locations, respectively. On average, nasal and temporal IOP readings were 0.75 and 0.37 mmHg lower than the central reading (p 0.05, r…
Two-year retrospective analysis of the international impact of Journal of Optometry: part II
The Journal of Optometry – Peer-reviewed Journal of the Spanish General Council of Optometrists- was launched in March 2008 publishing the first issue by September 2008. It is now reaching 2.5 years of activity in spreading clinical and scientific knowledge in the field of Optometry and Visual Science and related areas. Despite this short path within the international scientific publication scenario, it is appropriate to stop and reflect about the challenges, achievements and the numbers that are making J Optom a reference in this competitive area. In this editorial we will discuss the steps followed to setup the journal and the actual international impact in terms of audience from the read…
Corneal Aberrations, Contrast Sensitivity, and Light Distortion in Orthokeratology Patients: 1-Year Results.
Purpose. To evaluate the corneal higher-order aberrations (HOA), contrast sensitivity function (CSF), and light distortion (LD) in patients undergoing orthokeratology (OK). Methods. Twenty healthy subjects (mean age: 21.40 ± 8 years) with mean spherical equivalent refractive error M = −2.19 ± 0.97 D were evaluated at 1 day, 1 month, and 1 year after starting OK treatment. Monocular LD, photopic monocular CSF, and corneal HOA for 6 mm pupil size were measured. Results. LD showed an increase after the first night (𝑝 0.05). Spherical-like, coma-like, and secondary astigmatism HOA RMS increased significantly (𝑝 ≤ 0.022) from baseline to 1-month visit, remaining unchanged over the follow-up. C…
Light distortion of soft multifocal contact lenses with different pupil size and shape
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy
The purpose of this study was to analyze three commercial siloxane-hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observed in a cryogenic scanning electron microscope. The superficial ultrastructure of the siloxane-hydrogels was observed at the areas where the lens fractured during sample cryogenic preparation. There are qualitative differences among the three examined materials in the complex polymer network structure existing between the outer layer and the underlying polymer. CryoSEM, although destructive, is a useful tool …
Effects of Ageing on the Anterior Segment of the Eye Structure and Function
[Excerpt] The world will soon have more aged people than children and more people at extreme old age than ever before [1]. Improving quality of life as well as reducing severe disability due to age-related problems has become key for the health systems worldwide. The ageing of the world population has both structural and functional consequences for the human visual system; changes due to ageing occur in all the structures of the eye causing a variety of effects. Over the last few years, great advances in ophthalmic instrumentation allow the determination of ocular parameters to a level of detail without precedent. Such advances allowresearcherstodevelopspecificdevicesforvisualcorrection and r…